Evaluación de la vulnerabilidad sísmica en edificaciones aporticadas de hormigón reforzado entre 3 y 8 pisos en la zona 2 de la ciudad de Bucaramanga

dc.contributor.advisorChio Cho, Gustavo
dc.contributor.authorLozano Guerrero, Jesús Eduardo
dc.contributor.authorAlsina Velasquez, Jorge Mario
dc.date.accessioned2024-03-03T16:15:43Z
dc.date.available2006
dc.date.available2024-03-03T16:15:43Z
dc.date.created2006
dc.date.issued2006
dc.description.abstractDurante años la Ingeniería Civil en Colombia ha sido un factor importante en el desarrollo del país generando empleo e infraestructura, debido a la necesidad de mejorar la calidad de vida de la población. El sector de la construcción ha desarrollado cada día obras mas complejas dentro de los cuales se encuentran las edificaciones de gran altura, que en muchas ocasiones no fueron desarrolladas con parámetros de seguridad ya que el país no contaba con una normativa legal de diseño técnico de construcción que tuviese en cuenta la amenaza sísmica, produciendo lamentablemente grandes catástrofes en la historia del país que cobraban vidas humanas y daños materiales. Edificaciones construidas en Bucaramanga han sido diseñadas basadas en la NSR 98 que no tienen en cuenta los estudios realizados por INGEOMINAS de zonificacion sismo geotécnica, ya que estos fueron desarrollados posteriormente a esta norma presentando un espectro de diseño mas riguroso, con lo cual se plantea la necesidad de desarrollar un análisis estructural que tenga presente este espectro y genere unos resultados de comportamiento sísmico. El análisis a desarrollar en las estructuras esta basado en un comportamiento no lineal, metodología descrita en la normativa ATC-40, con ella se puede establecer un nivel de comportamiento final de la estructura. Esto permite analizar la forma en que la estructura se desenvuelve ante un sismo y si el estado final remanente de la estructura es seguro o no para la existencia de seres vivos en su interior. Clasificaremos edificaciones entre 3 y 8 pisos de sistema tipo pórtico en concreto reforzado, de estas escogeremos 10 en total ubicadas en la zona 2 de Bucaramanga y las analizaremos mediante la herramienta de software SAP-2000, que nos permite estudiar las estructuras en un comportamiento no-lineal como anteriormente mencionamos, esto involucra un espectro de demanda sísmica y un espectro de capacidad propia de la estructura o curva pushover. Posterior al análisis tomamos estos resultados y los ponderamos ubicándolos en estados de: colapso, daño severo, daño ligero o sin daño, con esto tendríamos unos estimativos calificativos del comportamiento de las estructuras. Evaluación de la vulnerabilidad sísmica en edificaciones aporticadas de hormigón reforzado entre 3 y 8 pisos en la zona 2 de la ciudad de Bucaramanga.
dc.description.abstractenglishDuring years the Civil Engineering in Colombia has been an important factor in the domestic development generating employment and infrastructure, due to the necessity of improving the quality of the population's life. The sector of the construction has developed every day works but complex inside which are the constructions of great height that were not developed since with safedeposit parameters the country in many occasions it didn't have a legal regulatory scheme of design construction technician that keeps in mind the seismic threat, producing big catastrophes regrettably in the domestic history that you/they charged human lives and property damage. Constructions built in Bucaramanga have been designed based since on the NSR 98 that don't keep in mind the studies carried out by INGEOMINAS of stratification earthquake geotechnics, these they were developed to this norm later on presenting a design spectrum but rigorous, with that which thinks about the necessity to develop a structural analysis that has present this spectrum and generate some results of seismic behavior. The analysis to develop in the structures this based one in a non-linear behavior, methodology described in the normative ATC-40, with her a level of final behavior of the structure can settle down. This allows to analyze the form in that the structure is unwrapped before an earthquake and if the non-volatile final state of the structure is safe or it doesn't stop the existence of alive beings in its interior. We will classify constructions in short between 3 and 8 floors of system type piazza reinforced, of these we will choose 10 in total located in the area 2 of Bucaramanga and we will analyze them by means of the software tool SAP-2000 that allows us to study the structures in a nolineal behavior as previously we mention, this involves a spectrum of seismic demand and a spectrum of capacity characteristic of the structure or curved pushover. Later to the analysis we take these results and we ponder them locating them in states of: I collapse, severe damage, I damage fast or without damage, therewith we would have some estimated epithets of the behavior of the structures. Evaluation of the seismic vulnerability in building of reinforced concrete between 3 and 8 levels in the zone 2 at bucaramanga city. Ability of Engineering fisicomecánicas. School of Engineering civil, Managing Engineer Gustavo Chio
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Civil
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/19297
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programIngeniería Civil
dc.publisher.schoolEscuela de Ingeniería Civil
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectVulnerabilidad Sismica Espectro De Respuesta Analisis Estatico No-Lineal Curva Pushover Niveles De Comportamiento
dc.subject.keywordSeismic Vulnerability Response Spectrum Nonlinear Static Analysis Pushover Curve Performance Levels
dc.titleEvaluación de la vulnerabilidad sísmica en edificaciones aporticadas de hormigón reforzado entre 3 y 8 pisos en la zona 2 de la ciudad de Bucaramanga
dc.title.englishEvaluation of the seismic vulnerability in building of reinforced concrete between 3 and 8 levels in the zone 2 at bucaramanga city.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado

Archivos

Bloque original

Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
7.47 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
888.14 KB
Formato:
Adobe Portable Document Format