Logotipo del repositorio

Publicación:
Evaluación estadística del desempeño analítico del método para la cuantificación de oro en muestras minerales mediante ensayo al fuego acoplado a espectrofotometría de absorción atómica desarrollado por el Laboratorio de Servicios Químicos, Minero-Metalúrgicos y Ambientales del GIMBA

dc.contributor.advisorPedraza Avella, Julio Andrés
dc.contributor.advisorGalvis Vargas, María Alejandra
dc.contributor.authorCuadrado Orduz, Karen Dahiana
dc.contributor.authorRondon Alvarado, Vivian Daniela
dc.contributor.evaluatorDuarte Duarte, Diana Paola
dc.contributor.evaluatorGomez Ramirez, Javier Enrique
dc.date.accessioned2026-08-26T16:10:13Z
dc.date.created2026-08-25
dc.date.embargoEnd2036-08-25
dc.date.issued2026-08-25
dc.description.abstractLa validación de métodos analíticos constituye un requisito esencial para garantizar la confiabilidad de los resultados y respaldar los sistemas de aseguramiento de calidad. En este contexto, el presente trabajo tuvo como objetivo validar el método para la determinación de oro en muestras sólidas mediante ensayo al fuego acoplado a espectrofotometría de absorción atómica (EF-EAA), desarrollado por el Laboratorio de Servicios Químicos, Minero-Metalúrgicos y Ambientales GIMBA, con el propósito de demostrar su aptitud para el uso previsto y aportar soporte técnico para una futura acreditación. La metodología se desarrolló en tres fases; inicialmente, se evaluó la robustez del método mediante un diseño factorial fraccionado, considerando variables críticas asociadas a las etapas de fusión y copelación. Posteriormente, se determinaron los parámetros de validación correspondientes a límite de detección, límite de cuantificación, selectividad, intervalo de trabajo, linealidad y exactitud mediante análisis estadísticos, empleando materiales de referencia certificados, muestras minerales y soluciones de calibración certificada. Finalmente, se integraron los resultados para identificar oportunidades de mejora orientadas al fortalecimiento del procedimiento analítico. Los resultados evidenciaron que el método es robusto frente a las variaciones operativas evaluadas, identificando la masa de carga fundente como la principal variable crítica. Asimismo, se establecieron un límite de detección del método de 0.081 g/ton y un límite de cuantificación de 0.22 g/ton, verificándose la influencia del blanco de reactivo en bajas concentraciones. El método presentó una respuesta lineal y proporcional dentro del intervalo de trabajo, con coeficientes de determinación superiores a 0.99, así como una precisión satisfactoria y una veracidad adecuada en los niveles medio y alto, mientras que para el tenor bajo se evidenció una sobreestimación del analito. Finalmente, se identificaron oportunidades de mejora para fortalecer el control de variables críticas, la confiabilidad y la trazabilidad del método, aportando soporte técnico para su optimización y una futura acreditación.
dc.description.abstractenglishAnalytical method validation is an essential requirement to ensure the reliability of analytical results and support quality assurance systems. In this context, the aim of this study was to validate the method for gold determination in solid samples by fire assay coupled with atomic absorption spectrophotometry (FA-AAS), developed by the Laboratorio de Servicios Químicos, Minero-Metalúrgicos y Ambientales GIMBA, in order to demonstrate its fitness for the intended use and provide technical support for future accreditation. The methodology was carried out in three phases; first, the robustness of the method was evaluated using a fractional factorial design, considering critical variables associated with the fusion and cupellation stages. Subsequently, the validation parameters, including detection limit, quantification limit, selectivity, working range, linearity, and accuracy, were determined through statistical analyses using certified reference materials, mineral samples, and certified calibration solutions. Finally, the results were integrated to identify improvement opportunities aimed at strengthening the analytical procedure. The results demonstrated that the method is robust against the evaluated operational variations, identifying the flux charge mass as the main critical variable. In addition, a method detection limit of 0.081 g/ton and a limit of quantification of 0.22 g/ton were established, confirming the influence of the reagent blank at low concentration levels. The method exhibited a linear and proportional response throughout the working range, with determination coefficients greater than 0.99, as well as satisfactory precision and adequate trueness at the medium and high concentration levels, whereas an overestimation of the analyte was observed at the low-grade level. Finally, improvement opportunities were identified to strengthen the control of critical variables, enhance the reliability and traceability of the method, and provide a technical basis for its optimization and future accreditation.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/48272
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectEnsayo al fuego
dc.subjectcuantificación de oro
dc.subjectmineral aurífero
dc.subjectvalidación de métodos
dc.subject.keywordFire assay
dc.subject.keywordgold determination
dc.subject.keywordgold-bearing ore
dc.subject.keywordmethod validation
dc.titleEvaluación estadística del desempeño analítico del método para la cuantificación de oro en muestras minerales mediante ensayo al fuego acoplado a espectrofotometría de absorción atómica desarrollado por el Laboratorio de Servicios Químicos, Minero-Metalúrgicos y Ambientales del GIMBA
dc.title.englishStatistical Evaluation of the Analytical Performance of the Method for Quantifying Gold in Mineral Samples Using Fire Assay Coupled with Atomic Absorption Spectrophotometry, Developed by the Laboratorio de Servicios Químicos, Minero-Metalúrgicos y Ambientales del GIMBA
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 4 de 4
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
56.01 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Carta-Confidencialidad.pdf
Tamaño:
139.79 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
168.55 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
2.04 MB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
2.17 KB
Formato:
Item-specific license agreed to upon submission
Descripción:

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031