Publicación: Revisión bibliográfica de los bioinhibidores utilizados para prevenir la corrosión en tuberías de acero API 5LX
| dc.contributor.advisor | García Barrios, Bianeth | |
| dc.contributor.advisor | Peña Ballesteros, Darío Yesid | |
| dc.contributor.author | Espinel Vesga, Juan Pablo | |
| dc.contributor.author | Zúñiga Archila, Karla Juliana | |
| dc.contributor.evaluator | Rojas Pérez, Lilia Carolina | |
| dc.contributor.evaluator | Duarte Duarte, Diana Paola | |
| dc.date.accessioned | 2025-10-28T15:28:15Z | |
| dc.date.available | 2025-10-28T15:28:15Z | |
| dc.date.created | 2025-10-23 | |
| dc.date.issued | 2025-10-23 | |
| dc.description.abstract | La corrosión en tuberías de acero API 5LX representa un desafío técnico y económico en la industria del petróleo y gas, debido a condiciones agresivas a las que se encuentran expuestas. Tradicionalmente, para mitigar este fenómeno se han empleado inhibidores químicos; sin embargo, su toxicidad, baja biodegradabilidad y efectos negativos en la salud humana han motivado la búsqueda de alternativas más sostenibles. En este estudio, se llevó a cabo una revisión de literatura de 528 artículos mediante la metodología PRISMA por título y resumen y 57 artículos con revisión completa, se identificaron inhibidores a partir de compuestos naturales con potencial anticorrosivo, ecológicos y aplicables industrialmente. Se reportan seis grupos de bioinhibidores a partir de: extractos vegetales, nanopartículas verdes, biopolímeros naturales, sintéticos verdes, biosurfactantes y molécula orgánica, el grupo más destacado fueron los extractos vegetales naturales. Se registraron los factores principales que influyen en la efectividad de estos, tales como: el medio, la temperatura, la concentración del inhibidor, entre otros. Adicionalmente, se realizó una comparación frente a los inhibidores convencionales, en los que se analizaron sus ventajas y desventajas respectivamente, por último, se evalúo la aplicación de compuestos cítricos, la cual se vio limitada debido a la poca disponibilidad de estudios en el acero API 5LX. En este sentido, es importante resaltar la viabilidad de los bioinhibidores, su alta efectividad que en muchos casos fue superior al 90%, aunque es necesario reconocer los desafíos de su efectividad en altas temperaturas y la falta de estudios respecto a condiciones dinámicas más reales. | |
| dc.description.abstractenglish | Corrosion in API 5LX steel pipes represents a technical and economic challenge in the oil and gas industry, due to the aggressive conditions to which they are exposed. Traditionally, chemical inhibitors have been used to mitigate this phenomenon; however, their toxicity, low biodegradability and negative effects on human health have motivated the search for more sustainable alternatives. In this study, a literature review of 528 articles was carried out using PRISMA methodology by title and abstract and 57 articles with complete review, inhibitors were identified from natural compounds with anticorrosive, ecological and industrially applicable potential. Six groups of bioinhibitors are reported from: plant extracts, green nanoparticles, natural biopolymers, green synthetics, biosurfactants and organic molecule, the most prominent group were natural plant extracts. The main factors influencing their effectiveness were recorded, such as: medium, temperature, inhibitor concentration, among others. Additionally, a comparison was made with conventional inhibitors, in which their advantages and disadvantages were analyzed, respectively. Finally, the application of citric compounds was evaluated, which was limited due to the limited availability of studies on API 5LX steel. In this sense, it is important to highlight the viability of bioinhibitors, their high effectiveness, which in many cases was higher than 90%, although it is necessary to recognize the challenges of their effectiveness at high temperatures and the lack of studies regarding more realistic dynamic conditions. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/46245 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
| dc.publisher.program | Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.title | Revisión bibliográfica de los bioinhibidores utilizados para prevenir la corrosión en tuberías de acero API 5LX | |
| dc.title.english | Literature Review of Bioinhibitors Used to Prevent Corrosion in API 5LX Steel Pipelines | |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 4 de 4
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 560.91 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Carta de autorización 1.pdf
- Tamaño:
- 158.15 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Carta de autorización 2.pdf
- Tamaño:
- 156.82 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.18 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: