Publicación: Desempeño sísmico de un edificio con muros delgados de concreto reforzado evaluando tres tipos de cuantía y dos tipos de acero de refuerzo (Barra corrugada y malla electrosoldada). Caso de estudio en Pereira, Colombia.
| dc.contributor.advisor | ARROYO AMELL ORLANDO DANIEL | |
| dc.contributor.author | ARDILA MUÑOZ CARLOS FERNANDO | |
| dc.contributor.evaluator | VARGAS CARVAJAL LAURA ANDREA | |
| dc.contributor.evaluator | ZAPATA ORDUZ LUIS EDUARDO | |
| dc.date.accessioned | 2026-06-09T17:15:19Z | |
| dc.date.created | 2026-06-04 | |
| dc.date.issued | 2026-06-04 | |
| dc.description.abstract | En las últimas décadas, el uso de muros delgados de concreto reforzado como sistema estructural ha experimentado un notable crecimiento en varios países de Latinoamérica, incluyendo Colombia. Este aumento se debe a las ventajas que ofrece en términos de rapidez de construcción, optimización de recursos y ahorro económico. Este sistema estructural se caracteriza por emplear muros con espesores mínimos de hasta 80 mm, reforzados con mallas electrosoldadas o barras de acero corrugado. En edificaciones residenciales de mediana altura construidas mediante procesos industrializados, el uso de mallas electrosoldadas es particularmente común. Sin embargo, estudios experimentales y observaciones posteriores a eventos sísmicos han generado dudas sobre su desempeño estructural, especialmente en zonas de amenaza sísmica moderada y alta, debido a su limitada capacidad de deformación, a posibles fallas frágiles asociadas a bajas cuantías y al uso de aceros de menor ductilidad. Investigaciones señalan que los elementos reforzados con mallas electrosoldadas pueden presentar una menor capacidad de deformación y ductilidad en comparación con aquellos reforzados con barras corrugadas convencionales (Carrillo et al., 2019). Esto podría influir significativamente en el comportamiento sísmico general de los edificios. Además, se ha identificado que en muchos casos las cuantías de refuerzo en el alma de los muros corresponden a valores cercanos a los mínimos exigidos por las normativas, lo que ha suscitado debates sobre si esos límites son realmente suficientes para garantizar un adecuado comportamiento sísmico. En este contexto, el objetivo de este trabajo es analizar el desempeño sísmico un edificio de muros delgados de concreto reforzado ubicado en la ciudad de Pereira, Colombia, comparando tres cuantías de refuerzo en el alma de los muros (la cuantía mínima exigida por la NSR-10 y dos cuantías superiores propuestas) y dos tipos de acero de refuerzo: barras corrugadas y mallas electrosoldadas. Para ello, se evalúa el comportamiento estructural de la edificación mediante análisis estáticos no lineales. Este procedimiento permite comparar la respuesta estructural, identificar posibles mecanismos de falla y estimar la probabilidad de colapso bajo diferentes configuraciones de refuerzo. También se busca verificar si los muros estructurales que están sometidos principalmente a flexión, requieren una cuantía mayor al mínimo establecido por la normativa para garantizar un desempeño sísmico adecuado. Los resultados de este estudio proporcionarán evidencia técnica sobre cómo el tipo de refuerzo y la cantidad de acero influyen en el comportamiento sísmico de edificaciones con muros delgados. | |
| dc.description.abstractenglish | In recent decades, the use of thin reinforced concrete (RC) walls as a structural system has experienced significant growth in several Latin American countries, including Colombia. This increase is mainly attributed to the advantages this construction method offers in terms of construction speed, resource optimization, and cost efficiency. This system is characterized by the use of walls with thicknesses as low as 80 mm, which are typically reinforced with welded wire mesh or deformed reinforcing bars. The former is commonly used in mid-rise residential buildings constructed using industrialized methods. However, experimental studies and observations following seismic events have raised concerns regarding their structural performance, particularly in moderate and high seismic hazard regions, due to their limited deformation capacity and the potential for brittle failure mechanisms associated with low reinforcement ratios and the use of reinforcing steels with reduced ductility. Previous research indicates that structural elements reinforced with welded wire mesh may exhibit lower deformation capacity and ductility compared with those reinforced with conventional deformed reinforcing bars (Carrillo et al., 2019). This difference may significantly influence the overall seismic behavior of buildings. Additionally, it has been observed that in many cases the reinforcement ratios provided in the wall web are close to the minimum values required by design codes, which has generated discussion regarding whether such limits are sufficient to ensure an adequate seismic performance. In this context, the objective of this research is to analyze the seismic performance of a thin reinforced concrete wall building located in the city of Pereira, Colombia, by comparing three reinforcement ratios in the wall web (the minimum ratio required by NSR-10 and two higher proposed ratios) and two types of reinforcing steel: deformed reinforcing bars and welded wire mesh. To achieve this objective, the structural behavior of the building is evaluated through nonlinear static analyses, allowing the comparison of the structural response, identification of potential failure mechanisms, and estimation of the probability of collapse under different reinforcement configurations. Furthermore, this study aims to verify whether structural walls primarily subjected to flexural demands require a reinforcement ratio greater than the minimum value established by the Colombian seismic design code to ensure an adequate seismic performance. The results of this study will provide technical evidence regarding how the type and amount of reinforcement influence the seismic behavior of buildings with thin reinforced concrete walls, enabling a critical assessment of current design practices and supporting potential recommendations for the design and evaluation of this type of structural system in seismic regions | |
| dc.description.degreelevel | Maestría | |
| dc.description.degreename | Magíster en Ingeniería Estructural | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/47793 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
| dc.publisher.program | Maestría en Ingeniería Estructural | |
| dc.publisher.school | Escuela de Ingenieria Civil | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Muros estructurales de concreto reforzado | |
| dc.subject | cuantía de refuerzo | |
| dc.subject | capacidad nominal | |
| dc.subject | optimización estructural | |
| dc.subject | seguridad estructural | |
| dc.subject.keyword | Reinforced concrete structural walls | |
| dc.subject.keyword | reinforcement ratio | |
| dc.subject.keyword | nominal capacity | |
| dc.subject.keyword | structural optimization | |
| dc.subject.keyword | structural safety | |
| dc.title | Desempeño sísmico de un edificio con muros delgados de concreto reforzado evaluando tres tipos de cuantía y dos tipos de acero de refuerzo (Barra corrugada y malla electrosoldada). Caso de estudio en Pereira, Colombia. | |
| dc.title.english | Seismic Performance Assessment of a Reinforced Concrete Thin-Wall Building Considering Three Reinforcement Ratios and Two Types of Steel Reinforcement (Deformed Bars and Welded Wire Mesh): A Case Study in Pereira, Colombia. | |
| dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Maestría | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorizacion.pdf
- Tamaño:
- 161.3 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 30.87 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: