Publicación: Control of Three Phase Inverters Under Voltage Sags
| dc.contributor.advisor | Mantilla Villalobos, María Alejandra | |
| dc.contributor.advisor | Rey López, Juan Manuel | |
| dc.contributor.advisor | Garnica López, Miguel Andrés | |
| dc.contributor.author | Rincon Adarme, David Javier | |
| dc.contributor.evaluator | Duarte Gualdron, Cesar Antonio | |
| dc.contributor.evaluator | Osma Pinto, German Alfonso | |
| dc.contributor.evaluator | Miret Tomas, Jaume | |
| dc.contributor.evaluator | Serna Súarez, Ivan David | |
| dc.contributor.evaluator | Velasco Garcia, Manel | |
| dc.date.accessioned | 2026-02-06T13:13:55Z | |
| dc.date.available | 2026-02-06T13:13:55Z | |
| dc.date.created | 2026-02-04 | |
| dc.date.embargoEnd | 2026-08-04 | |
| dc.date.issued | 2026-02-04 | |
| dc.description.abstract | Esta tesis doctoral se enfoca en mejorar el desempeño de inversores de potencia conectados a la red durante hundimientos de tensión. Se realizó una revisión de diferentes códigos de red (GC) para definir los requerimientos y las características de operación deseadas del convertidor durante hundimientos de tensión. Con base en esta revisión, esta tesis presenta dos contribuciones principales. La primera contribución es un algoritmo de sincronización con un corto tiempo de stablecimiento, lo cual es crítico para la operación de inversores conectados a la red durante hundimientos de tensión. El algoritmo emplea un nuevo extractor de secuencias de dos muestras (TSSE) combinado con un seguidor de fase (PLL). El algoritmo TSSE extrae las componentes de secuencia positiva y negativa mientras que el PLL se usa para estimar la frecuencia fundamental de la red. Para mitigar el efecto de la distorsión armónica en la estimación del TSSE y del PLL, se utiliza un filtro Butterworht y un filtro de cancelación de señal retrasada (DSC), respectivamente. El desempeño del algoritmo de sincronización se evalúa a través de pruebas experimentales en lazo abierto y en lazo cerrado. Los resultados muestran la eficacia del TSSE-DCS en mejorar la estimación de las componentes de secuencia durante condiciones de red anormales para convertidores seguidores de red. La segunda contribución es un algoritmo generador de la corriente de referencia o estrategia de corriente, que cumple con los requerimientos de la nueva generación de GC. Esta estrategia considera las condiciones pre falla para realizar la reducción de corriente, priorizando la inyección de corriente reactiva. Como objetivo segundario al soporte de tensión, la estrategia reduce las oscilaciones en la potencia activa instantánea y por ende en la tensión de la barra DC, al ajustar la inyección de corriente reactiva a través de la secuencia negativa de acuerdo al estándar alemán VDE-AR-N4120. El desempeño de la estrategia es validado por medio de simulaciones de un sistema de transmisión y pruebas experimentales en un modelo escalado. Los resultados confirman que la estrategia mitiga las oscilaciones en la potencia activa instantánea y permite incrementar la inyección de potencia activa proporcionando soporte de tensión a la red. | |
| dc.description.abstractenglish | The present doctoral thesis focuses on enhancing the performance of grid-connected inverters under voltage sags. A literature review on grid codes (GC) was conducted to define Low-Voltage Ride-Through (LVRT) requirements and desired converter operating characteristics. Based on those, this thesis presents two major contributions. The first contribution is a synchronization algorithm that exhibits a short settling time, which is critical for the operation of grid-connected converters under voltage sags. The algorithm employs a novel two-sample sequence extractor (TSSE) combined with a phase-locked loop (PLL). The TSSE extracts the positive and negative sequences while the PLL is used to estimate the grid frequency. To mitigate harmonic distortion effects on the TSSE and PLL estimations, a third-order Butterworth filter and a Delayed Signal Cancellation (DSC) filter are used, respectively. The algorithm's performance is evaluated through experimental tests in open- and closed-loop configurations. Results underscore the efficacy of the DSC-TSSE in enhancing the estimation of the voltage sequences during grid abnormal conditions for grid-following converters. The second contribution is a reference signal generator, or current strategy, that meets new generation GC requirements. This strategy incorporates pre-fault conditions to manage current scale down, prioritizing reactive current injection. As a secondary objective to the voltage support, it reduces the instantaneous active power oscillations and thus DC-bus voltage fluctuations, by adjusting the reactive negative sequence current injection in compliance with the German VDE-AR-N 4120 standard. The performance of the proposed strategy is validated through transmission system simulations and experimental tests in a scaled-down model. Results confirm that the strategy mitigates instantaneous active power oscillations and allows increased active power supply while voltage support is provided to the grid. Overall, the proposed synchronization algorithm and current reference strategy address key challenges faced by grid-connected inverters under voltage sags. Together, they improve the converter's dynamic response, ensure compliance with evolving grid code requirements, and enhance fault ride-through capability. The thesis concludes by presenting conclusions and future research lines. | |
| dc.description.cvlac | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001611805 | |
| dc.description.degreelevel | Doctorado | |
| dc.description.degreename | Doctor en Ingeniería | |
| dc.description.googlescholar | https://scholar.google.com/citations?user=_MpTytUAAAAJ&hl=en | |
| dc.description.orcid | https://orcid.org/0000-0001-7852-9834 | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/46966 | |
| dc.language.iso | eng | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
| dc.publisher.program | Doctorado en Ingeniería: Área Ingeniería Eléctrica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_f1cf | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-SinDerivadas 2.5 Colombia (CC BY-ND 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Algoritmo de sincronización | |
| dc.subject | Estrategia de inyección corriente | |
| dc.subject | Fuentes controladas de tensión | |
| dc.subject | Hundimientos de tensión | |
| dc.subject | Inversor de potencia | |
| dc.subject.keyword | Low-Voltage Ride-Trough | |
| dc.subject.keyword | Synchronization Algorithm | |
| dc.subject.keyword | Current Strategy | |
| dc.subject.keyword | Voltage Source Converter | |
| dc.subject.keyword | Power Inverter | |
| dc.title | Control of Three Phase Inverters Under Voltage Sags | |
| dc.title.english | Control of Three Phase Inverters Under Voltage Sags | |
| dc.type.coar | http://purl.org/coar/resource_type/c_db06 | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Doctorado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 4 de 4
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 1.3 MB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Carta de confidencialidad.pdf
- Tamaño:
- 211.28 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Carta de autorizacion.pdf
- Tamaño:
- 596.67 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Documento.pdf
- Tamaño:
- 17.87 MB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: