Publicación: Evaluación del aprovechamiento del gas natural del campo San Francisco en el aseguramiento de la continuidad operativa de la planta de tratamiento de gas Dina-énfasis en ingeniería de gas y procesos
| dc.contributor.advisor | Chamorro Narvaez, Jairo Jesse | |
| dc.contributor.author | Corredor, Diego Raúl | |
| dc.date.accessioned | 2024-03-04T00:48:13Z | |
| dc.date.available | 2020 | |
| dc.date.available | 2024-03-04T00:48:13Z | |
| dc.date.created | 2020 | |
| dc.date.issued | 2020 | |
| dc.description.abstract | El objetivo de esta investigación es evaluar el aprovechamiento del gas natural del campo San Francisco en el aseguramiento de la continuidad operativa de la Planta de Tratamiento de Gas Dina-Énfasis en Ingeniería de Gas y procesos. Metodológicamente, tiene un diseño de campo, la unidad de análisis está conformada por el gas procesado en los centros de generación Dn, Mn y Te, para ser convertido en energía (MW). Se obtuvo como resultado que, en el CGD para generar 1 MW se requieren 225 KSCFD, en el CGT para generar 1 MW se requiere 225 KSCFD, y en el CGM para generar 1 MW se requieren entre 360-380 KSCFD. Para efectos de los cálculos realizados se utilizó como valor estándar 360 KSCFD. Al evaluar el modelamiento integrado de simulación del trasporte, tratamiento y procesamiento de la corriente de gas natural, y en comparación con estudios previo de Ecopetrol (2017), se tiene que, efectuando sensibilidades de mezcla, el resultado final de unir en la entrada de la Planta de Gas Dina PTGD con la corriente proveniente del campo San Francisco, cambia la dinámica operativa de la Unidad de Procesos y altera los índices de Recuperación de Líquidos esperados. Los análisis de sensibilidad en la unidad de endulzamiento y de deshidratación demostraron que con un aumento del caudal de la planta de tratamiento de gas si se pueden obtener las eficiencias de purificación sin aumento significativo de los consumibles como son etilenglicol, metil-dietanolamina. Al unir las corrientes de la batería DA`s con la de San Francisco las unidades de proceso de PTGD no se ven afectadas hidráulica ni térmicamente y en términos de transporte de masa sin que disminuyan la calidad del gas que va a ser usado en las centrales de generación eléctricas. Por lo tanto, la operatividad de la planta de gas no se ve afectada al cambiar el caudal y la composición del gas de entrada. El análisis económico demostró que la eficiencia en costos de energía/anual tiene un valor de 1.713.010.329 COP/cte. por el ingreso de 1000 KPCFD hacia la PTGD este saldo a favor en el balance anual de la planta representa un mejor desempeño operacional. | |
| dc.description.abstractenglish | The objective of this research is to evaluate the use of natural gas from the San Francisco field to ensure the operational continuity of the Dina Gas Treatment Plant-Emphasis on Gas and Process Engineering. Methodologically, the research has a field design. The analysis unit is made up of the gas processed at the Dn, Mn and Te generation centers, to be converted into energy (MW). It was obtained as a result that, in the CGD to generate 1 MW, 225 KSCFD was found, in the CGT to generate 1 MW, 225 KSCFD was required, and in the CGM to generate 1 MW, it was considered to be between 360 and 380 KSCFD. For the purposes of the calculations performed, 360 KSCFD is considered the standard value. When evaluating the transportation, treatment and processing integrated simulation model of natural gas streams , and it is compared with previous studies by Ecopetrol (2017), by performing mixture sensitivities it is found that the final result of mixing the San Francisco field stream with the Dina Gas Plant gas inlet stream, changes the Process Unit operational dynamics and alters the expected Liquid Recovery rates. Sensitivity analyzes in the sweetening and dehydration units showed that with flow rate increments in the gas treatment plant, purification efficiencies can be obtained without significant increase in consumables such as ethylene glycol, methyl diethanolamine. By mixing the DA`s battery stream and San Francisco stream, the PTGD process units are not affected neither hydraulically nor thermally or mass transfer without a quality reduction in the gas stream to be used in the power plants. Therefore, the operation of the gas plant is not affected by changing the inlet gas flow rate or composition. The economic analysis showed that the savings in yearly energy costs are around $1,713,010,329 COP / cte. due to the increment of 1,000 KPCFD to the PTGD, this plants yearly balance represents a better operational performance. | |
| dc.description.degreelevel | Maestría | |
| dc.description.degreename | Magíster en Ingeniería de Petróleos y Gas | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/40572 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Maestría en Ingeniería de Petróleos y Gas | |
| dc.publisher.school | Escuela de Ingeniería de Petróleos | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Gas | |
| dc.subject | Compresión | |
| dc.subject | Generación | |
| dc.subject | Electricidad | |
| dc.subject.keyword | Gas | |
| dc.subject.keyword | Compression | |
| dc.subject.keyword | Generation | |
| dc.title | Evaluación del aprovechamiento del gas natural del campo San Francisco en el aseguramiento de la continuidad operativa de la planta de tratamiento de gas Dina-énfasis en ingeniería de gas y procesos | |
| dc.title.english | Evaluation of the use of natural gas from the san francisco field in the assurance of the operational continuity of the dina gas treatment plant-emphasis on gas and process engineering* | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_bdcc | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Maestria | |
| dspace.entity.type | Publication |