Publicación: Predicción de las fracciones sara de fondos de vacío de crudos colombianos, por métodos quimiometricos utilizando espectroscopia de fluerescencia inducida por láser (lif)
| dc.contributor.advisor | Mejía Ospino, Enrique | |
| dc.contributor.advisor | Orrego, Jorge Armando | |
| dc.contributor.author | Ballesteros Lancheros, Sandra Lucia | |
| dc.date.accessioned | 2024-03-03T18:05:46Z | |
| dc.date.available | 2010 | |
| dc.date.available | 2024-03-03T18:05:46Z | |
| dc.date.created | 2010 | |
| dc.date.issued | 2010 | |
| dc.description.abstract | En el presente trabajo se presenta la potencialidad de la Espectroscopia de Fluorescencia Inducida por Láser (LIF) como técnica de caracterización de muestras complejas como los fondos de vacío de petróleos colombianos. El trabajo consistió en construir modelos matemáticos a partir de los espectros de fluorescencia de las muestras, que permitieron determinar la composición porcentual de compuestos saturados, aromáticos, resinas y asfaltenos en los fondos de vacío de petróleo de origen colombiano. Se utilizó análisis de componentes principales (PCA) para reducir la dimensionalidad de los datos espectrales y luego regresión de mínimos parciales (PLS-R) para generar el modelo predictivo de cada una de las composiciones por medio de correlaciones lineales de las matrices de los datos espectroscópicos y las concentraciones teóricas. La obtención de los espectros de fluorescencia se llevó a cabo en un espectrómetro ensamblado en el laboratorio en el que se utilizó como fuente de excitación un láser de nitrógeno pulsado, para enfocar la radiación lentes cilíndricos con 10 y 15 cm de distancia focal, y como porta muestra una celda de cuarzo con 1 cm de paso de luz. Los modelos de predicción fueron desarrollados empleando el rango espectral de 346.55 a 750.0 nm para los saturados, asfaltenos y resinas, y para los aromaticos de 347.63 a 699.83 nm. La validación mostró resultados satisfactorios para la predicción de resinas, asfaltenos, aromáticos y saturados, en los fondos de vacío. Para cada uno de ellos se obtuvieron errores estándar de predicción (RMSEP) de 1.29, 1.863, 1.94 y 2,42 respectivamente. En todos los casos el coeficiente de correlación (R2) entre los valores de referencia y predichos por los modelos fue superior a 0,83. | |
| dc.description.abstractenglish | This paper presents shows the potential of spectroscopy Laser Induced Fluorescence (LIF) as a technique of complex samples such as vacuum residues from Colombian crudes. In this work were obtained mathematical models based on the fluorescence spectra of samples for determining the percentage composition of saturated, aromatic, resins and asphaltenes compounds in the vacuum residue. We used principal component analysis (PCA) to reduce the dimensionality of spectral data and then partial least squares regression (PLS-R) to build the predictive model of each of the compositions by means of linear correlations of the matrices of spectroscopic data and theoretical concentrations. The acquisition of fluorescence spectra was carried out in a spectrometer assembled in the laboratory that was used as excitation source of nitrogen pulsed laser, to focus the radiation cylindrical lenses with 10 and 15 cm focal length, and a quartz cell as carries samples with 1 cm of light passage. The prediction models were developed using the spectral range of 346.55 to 750.0 nm for saturated, asphaltenes and resins and for the aromatics from 347.63 to 699.83 nm. Validation results were successful for predicting resins, asphaltenes, aromatics and saturated in the vacuum residues. Standard errors of prediction (RMSEP) were 1.29, 1.863, 1.94 and 2,42 respectively. Multiple correlation coefficients (R2) for reference and LIF values were higher than | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/23417 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ciencias | |
| dc.publisher.program | Química | |
| dc.publisher.school | Escuela de Química | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Fluorescencia | |
| dc.subject | Fondos De Vacío | |
| dc.subject | Pls | |
| dc.subject | Pca. | |
| dc.subject.keyword | Fluorescence | |
| dc.subject.keyword | Vacuum Residues | |
| dc.subject.keyword | Pls | |
| dc.subject.keyword | Pca. | |
| dc.title | Predicción de las fracciones sara de fondos de vacío de crudos colombianos, por métodos quimiometricos utilizando espectroscopia de fluerescencia inducida por láser (lif) | |
| dc.title.english | Predicion of sara fractions from crude vacuum residues colombian, by chemometric methods using spectroscopy of laser induced fluorescence spectroscopy (lif). | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 254.31 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 175.83 KB
- Formato:
- Adobe Portable Document Format
