Logotipo del repositorio

Publicación:
Evaluación fisicoquímica del proceso anaerobio de la planta de tratamiento de aguas residuales (ptar) cervecería del valle - Bavaria

dc.contributor.advisorCastro Molano, Liliana del Pilar
dc.contributor.authorMoran Rubiano, Mario Sebastian
dc.date.accessioned2024-03-03T22:10:35Z
dc.date.available2015
dc.date.available2024-03-03T22:10:35Z
dc.date.created2015
dc.date.issued2015
dc.description.abstractLos vertimientos realizados por la planta de tratamiento de aguas residuales (PTAR) de la Cervecería del Valle Bavaria, deben cumplir con los decretos establecidos por el ministerio de medio ambiente, mediante los cuales se reglamenta el uso del agua y los residuos líquidos. Debido a esto se deben controlar distintos parámetros no solo con la finalidad de cumplir las normas ambientales, si no con el hecho de llevar a cabo el proceso en óptimas condiciones. La PTAR de la Cervecería Bavaria está conformada por dos secciones, la primera corresponde al proceso anaerobio (incluye tanques donde se realizan procesos fisicoquímicos que llevan a cabo de forma aerobia) y la segunda al proceso biológico y fisicoquímico aerobio. Este trabajo centra su análisis en el proceso anaerobio, durante un periodo de 59 días se evaluó el estado del proceso anaerobio, monitoreando los parámetros que tienen mayor relevancia y los valores en los cuales se deben mantener para llevar a cabo el proceso en óptimas condiciones, estos parámetros son pH, AGV, SSV, SST, DBO, ALC, biogás, entre otros, también se realizó una caracterización fisicoquímica de los efluentes producidos por las áreas de la Cervecería del Valle, en la cual se identificaron específicamente de que procesos provienen las descargas que alteran y generan afectaciones significativas en la planta, evitando que se opere dentro de los rangos determinados para cada equipo y etapa, provocando disminuciones en la eficiencia del proceso. Mediante este trabajo se pudo concluir que las descargas provenientes de las áreas de elaboración y envase son las que generan una mayor afectación sobre el proceso anaerobio llevado a cabo en la planta, dado que los efluentes producidos por estas alteran de forma significativa los parámetros mencionados anteriormente, por otro lado el estado actual del lodo en el reactor anaerobio no es el ideal, por lo cual no se alcanza la máxima remoción de la carga orgánica del agua residual. Por último cabe resaltar que las paradas de planta por aseos semanales que se realizan en el reactor, entorpecen, descompensan y alteran el óptimo funcionamiento del proceso, dado que imposibilitan que el reactor alcance y mantenga una operación eficiente a lo largo del tratamiento de los efluentes recibidos por la planta de tratamiento de aguas residuales.
dc.description.abstractenglishDumping made by the wastewater treatment plant (WWTP) Brewery of Valle - Bavaria, they must comply with the decrees established by the ministry of environment, whereby the use of water and liquid waste is regulated. Because of this, they must not only control different parameters in order to meet environmental standards, if not the fact of conducting the process under optimal conditions. The WWTP Brewery Bavaria consists of two sections, the first is the anaerobic process (includes tanks which are carried out physicochemical processes carried out aerobically) and the second aerobic biological and physico-chemical process. This paper focuses its analysis on the anaerobic process for a period of 59 days the status of the anaerobic process was evaluated by monitoring the parameters that are most relevant and values which must be maintained to carry out the process under optimal conditions, these parameters are pH, VFA, SSV, TSS, BOD, ALC, biogas, among others, a physicochemical characterization of the effluents produced by the areas of the Brewery of Valle, where are specifically identified in this process was also carried out the analysis of discharges that alter and create significant effects on the plant, avoiding operating within the range specified for each stage, causing decreased on the efficiency of the process. Through this work it was concluded that the discharges from the areas of processing and packaging are generating greater involvement on the anaerobic process carried out on the plant, since the effluents produced by these significantly alter the parameters mentioned above on the other hand the current state of the sludge in the anaerobic reactor is not ideal, so the maximum removal of the organic load of waste water is not reached. Finally it should be noted that plant shutdowns for weekly cleaning that take place in the reactor, hinder, decompensate and alter the optimum operation of the process, since it disables that the reactor reaches and maintains an efficient operation during the whole treatment of effluent received for the plant of treatment of wastes water.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/33057
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectAlcalinidad
dc.subjectÁcidos Grasos Volátiles
dc.subjectSólidos Suspendidos Volátiles
dc.subjectSólidos Suspendidos Totales
dc.subjectDemanda Química De Oxígeno.
dc.subject.keywordAlkalinity
dc.subject.keywordVolatile Fatty Acids
dc.subject.keywordVolatile Suspended Solids
dc.subject.keywordTotal Suspended Solids
dc.subject.keywordChemical Oxygen Demand.
dc.titleEvaluación fisicoquímica del proceso anaerobio de la planta de tratamiento de aguas residuales (ptar) cervecería del valle - Bavaria
dc.title.englishEvaluation of the anaerobic process wastewater treatment plant (wwtp) brewery of valle - bavaria.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
278.83 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
2.7 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
199.5 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031