Publicación: Detección de sobreexpresión de receptores folatos en muestras cervicales mediante sensor cuántico de dióxido de titanio
| dc.contributor.advisor | Miranda, David Alejandro | |
| dc.contributor.advisor | Gonzalez Quitián, Adriana Inés | |
| dc.contributor.advisor | Corso Salamanca, Jairo | |
| dc.contributor.author | Medina Medina, Laura Melissa | |
| dc.contributor.evaluator | Celis Amortegui, Marcela | |
| dc.contributor.evaluator | Corzo Mantilla, Sandra Patricia | |
| dc.date.accessioned | 2026-03-10T15:10:59Z | |
| dc.date.available | 2026-03-10T15:10:59Z | |
| dc.date.created | 2026-02-03 | |
| dc.date.issued | 2026-02-03 | |
| dc.description.abstract | El cáncer de cuello uterino continúa siendo un desafío relevante en salud pública, especialmente en países de ingresos bajos y medios donde persisten barreras para el acceso oportuno al tamizaje. La sobreexpresión del receptor de folato alfa (FRα) en lesiones premalignas y malignas lo posiciona como un biomarcador atractivo para métodos diagnósticos alternativos. El objetivo de este estudio fue evaluar la capacidad de un biosensor cuántico de dióxido de titanio (TiO₂), funcionalizado con ácido fólico, para diferenciar entre células cervicales normales y células con alteraciones premalignas o malignas mediante espectroscopia de impedancia electroquímica. Se realizó un estudio transversal de prueba de concepto con dos grupos: mujeres con diagnóstico citológico o histopatológico alterado, y mujeres con dos citologías negativas consecutivas. Cada muestra fue medida individualmente utilizando sensores de uso único, con registro pareado del blanco (PBS) para cada placa. El análisis estadístico empleó la prueba U de Mann–Whitney debido a la distribución no normal de los datos. El parámetro electroquímico S1 mostró una diferencia estadísticamente significativa entre los grupos (U = 85.0; p = 0.0091), siendo menor en las pacientes con lesiones, lo cual es coherente con una mayor sobreexpresión de FRα. El conteo celular equivalente entre grupos permitió descartar la cantidad de material biológico como fuente de variación, indicando que S1 refleja diferencias biológicas genuinas. Los resultados validan la capacidad discriminatoria preliminar del sensor de TiO₂ funcionalizado con ácido fólico, evidenciando su potencial como herramienta de triage rápido y de bajo costo para la detección temprana de alteraciones cervicales. Sin embargo, se requiere continuar el proceso investigativo mediante estudios con muestras ampliadas, correlación molecular y evaluación en escenarios reales de tamizaje para consolidar esta tecnología como un recurso clínico aplicable. | |
| dc.description.abstractenglish | Cervical cancer remains a major public health concern, particularly in low- and middle-income countries where access to timely screening is limited. The folate receptor alpha (FRα), known to be overexpressed in premalignant and malignant cervical lesions, represents a promising biomarker for innovative diagnostic strategies. This proof-of-concept study evaluated the ability of a titanium dioxide (TiO₂) quantum sensor functionalized with folic acid to distinguish normal cervical cells from those with premalignant or malignant changes using electrochemical impedance spectroscopy. A cross-sectional study was conducted with two groups: women with altered cytological or histopathological findings, and women with two consecutive negative cytologies. Each cervical sample was analyzed individually using single-use sensors, including paired measurements with a PBS blank for each plate. Because the data showed non-normal distribution, the Mann–Whitney U test was applied. There was a statistically significant difference in the electrochemical parameter S1 between the two groups (U = 85.0; p = 0.0091), with lower S1 values in the lesion group, consistent with increased FRα overexpression. The equivalent cellularity between groups confirmed that variations in S1 were not due to sample quantity, but rather reflected true biological differences. These findings support the preliminary discriminative capacity of the TiO₂–folic acid sensor, suggesting its potential as a rapid, low-cost triage tool for early detection of cervical abnormalities. Further research—including larger sample sizes, molecular correlation, and evaluation in real-world screening contexts—is necessary to advance the development of this diagnostic technology | |
| dc.description.degreelevel | Especialización | |
| dc.description.degreename | Especialista en Ginecología y Obstetricia | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Facultad de Salud | |
| dc.identifier.reponame | Escuela de Medicina | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/47368 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Especialización en Ginecología y Obstetricia | |
| dc.publisher.program | Especialización en Ginecología y Obstetricia | |
| dc.publisher.school | Escuela de Medicina | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución 2.5 Colombia (CC BY 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Neoplasias del Cuello Uterino | |
| dc.subject | Receptores de Folato | |
| dc.subject | Biosensores | |
| dc.subject | Dióxido de Titanio | |
| dc.subject | Impedancia Eléctrica | |
| dc.subject.keyword | Uterine Cervical Neoplasms | |
| dc.subject.keyword | Folate Receptors | |
| dc.subject.keyword | Biosensing Techniques | |
| dc.subject.keyword | Titanium Dioxide | |
| dc.subject.keyword | Electric Impedance | |
| dc.title | Detección de sobreexpresión de receptores folatos en muestras cervicales mediante sensor cuántico de dióxido de titanio | |
| dc.title.english | Detection of folate receptor overexpression in cervical samples using a titanium dioxide quantum sensor | |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta_Autorización_Uso.pdf
- Tamaño:
- 146.83 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de Proyeto.pdf
- Tamaño:
- 398.38 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción:
