Publicación: Implementación de una metodología para la medición de la acidez de catalizadores por análisis FTIR de piridina adsorbida en el ICP y transferencia tecnológica de esta técnica al CICAT-UIS
| dc.contributor.advisor | Baldovino Medrano, Victor Gabriel | |
| dc.contributor.advisor | Ballesteros Rueda, Luz Marina | |
| dc.contributor.advisor | Pérez Martínez, David de Jesús | |
| dc.contributor.author | Carrillo Cortes, Jennifer Katherine | |
| dc.contributor.author | Cuello Penso, Felix Manuel | |
| dc.date.accessioned | 2024-03-03T23:14:35Z | |
| dc.date.available | 2017 | |
| dc.date.available | 2024-03-03T23:14:35Z | |
| dc.date.created | 2017 | |
| dc.date.issued | 2017 | |
| dc.description.abstract | La mayoría de las técnicas utilizadas para la medición de acidez de catalizadores presentan gran disparidad en sus resultados y no permiten distinguir aspectos importantes como la naturaleza o fortaleza ácida de los mismos. Por tanto, se decidió implementar una metodología para la medición de acidez por la técnica de análisis FTIR (Fourier Transform Infrared) de piridina adsorbida (la cual permite evaluar la naturaleza, concentración y fortaleza de los sitios ácidos en catalizadores) en las instalaciones del Instituto Colombiano del Petróleo (ICP). El presente proyecto expone los resultados obtenidos luego de la implementación de esta metodología en el ICP y presenta los resultados de la transferencia tecnológica al Centro de Investigaciones en Catálisis (CICAT). Se realizó el diseño, montaje y puesta en marcha de un sistema de medición de acidez que cuenta con algunas ventajas significativas respecto al montaje del ICP: (1) medición de hasta seis muestras por prueba, (2) ubicación de la termocupla del horno cerca a la muestra, (3) generación de vacío más eficiente y (4) conexiones prácticas y fáciles de manipular para las secciones de vidrio. Se estimó la reproducibilidad de la técnica, obteniendo diferencias porcentuales entre 16.3 y 33.1% para los resultados de las mediciones de ambos montajes. También se evaluó la repetibilidad del sistema construido para el CICAT tomando la desviación estándar como para la concentración de sitios ácidos Brønsted y ±9.7 sitios ácidos tipo Lewis, ambos con un nivel de confiabilidad del 95%. | |
| dc.description.abstractenglish | Most of the techniques used for the measurement of the acidity of the catalysts show great disparity in their results and do not allow to distinguish some important aspects such as the acidic nature or strength of the same. Therefore, it was decided to implement a methodology for the measurement of acidity by the Fourier Transform Infrared (FTIR) technique of adsorbed pyridine (which allows to evaluate the nature, concentration and strength of the acid sites in catalysts) in the facilities of the Institute Colombian Petroleum (ICP). This project shows the results obtained after the implementation of this methodology in the ICP and shows the results of the technological transfer to the Center of Investigations in Catalysis (CICAT). The design, assembly and start-up of an acidity measuring system was performed, with some significant advantages with respect to the ICP assembly: (1) measurement of up to six samples per test, (2) location of the furnace thermocouple next to the sample, (3) more efficient vacuum generator and (4) practical and easy to handle connections for glass sections. The reproducibility of the technique was estimated, obtaining percentage differences between 16.3 and 33.1% for the results of the measurements of both assemblies. We also evaluated the repeatability of the system constructed for the CICAT, taking the standard deviation as a measure of the system's random error; A margin of error of ± 15.3 mol / g was obtained for the concentration of Brønsted acid sites and ± 9.7 mol / g for the concentration of Lewis acid sites, both with a reliability level of 95%. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/35782 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Medición De Acidez | |
| dc.subject | Fortaleza Ácida | |
| dc.subject | Metodología | |
| dc.subject | Análisis Ftir | |
| dc.subject | Transferencia Tecnológica. | |
| dc.subject.keyword | Measurement Of Acidity | |
| dc.subject.keyword | Acid Strength | |
| dc.subject.keyword | Methodology | |
| dc.subject.keyword | Ftir Analysis | |
| dc.subject.keyword | Technological Transfer. | |
| dc.title | Implementación de una metodología para la medición de la acidez de catalizadores por análisis FTIR de piridina adsorbida en el ICP y transferencia tecnológica de esta técnica al CICAT-UIS | |
| dc.title.english | Implementation of a methodology for the measurement of acidity of catalysts by fiber analysis of pyridine adsorbid at the colombian institute of petroleum (icp) and technological transfer of this technique to cicat-uis | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 430.28 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 311.37 KB
- Formato:
- Adobe Portable Document Format
