Publicación: Implementación de la metodología para la determinación de cianuro libre en las aguas suministradas por el laboratorio departamental de salud pública mediante el método: voltamperometría de redisolución
| dc.contributor.advisor | Laverde Catano, Dionisio Antonio | |
| dc.contributor.author | Sáenz García, Oscar Eduardo | |
| dc.contributor.author | Valderrama Rios, Claudia Marcela | |
| dc.date.accessioned | 2024-03-03T18:13:30Z | |
| dc.date.available | 2010 | |
| dc.date.available | 2024-03-03T18:13:30Z | |
| dc.date.created | 2010 | |
| dc.date.issued | 2010 | |
| dc.description.abstract | En la actualidad los investigadores han venido desarrollando diferentes métodos para la determinación de sustancias no permisibles en aguas de consumo humano tales como cianuro, mercurio, plomo etc.; que a su vez obtengan resultados sin interferencias con bajo consumo tanto energético como de reactivos. Es así como, el método voltamperometría de redisolución nos permite la determinación de cianuro a concentraciones tan bajas como ppm (partes por millón) en tiempos muy cortos, valores bajos de reactivos y consumo energético. El objetivo principal de este estudio es Implementar un método para la determinación de cianuro libre en aguas mediante voltamperometría de redisolución con adición estándar, en el Laboratorio Departamental de Salud Pública de Santander por medio del equipo METROHM 746 VA TRACE ANALYCER con electrodo de gotas de mercurio. Para ello se identificaron parámetros como: tiempo de caída de la gota de mercurio (t. step), tiempo de homogenización (t. stir), pH óptimo de trabajo y la precisión y exactitud del método. La metodología que se siguió fue la preparación de electrolito soporte: (c(H3BO3)=0.2 mol/L, c(KOH)=0.17 mol/L, pH=10.) y las soluciones estándar: (100gCN-1/L, 70gCN-1/L, 800gCN-1/L), seguido se realizó la adecuación de parámetros óptimos de trabajo (pH=10.5 unidades, t. stirr = 600 s y t.step= 0.80 s.); luego se determinaron los valores de precisión y exactitud, posterior a esto se realizó la curva de calibración como parte inicial del método, finalmente se analizaron muestras problema. Los resultados obtenidos nos demostraron la excelente precisión y exactitud del método, debido a sus bajos valores de incertidumbre y desviación estándar. Además, se realizó la determinación de cianuro de aguas procedentes del Rio California para evaluar la técnica implementada, encontrando la presencia de cianuro en cantidades mayores a las permisibles en la legislación colombiana (0.05 mgCN-1/L), esto debido a las minas artesanales ubicadas en la región. | |
| dc.description.abstractenglish | Currently researchers have been developing different methods for determining non allowable substances in water for human consumption such as cyanide, mercury, lead, etc. Which in turn, this methods would produce results without interferences and with both low energy consumption as reagents. Thus, the stripping voltammetry allow us the cyanide determination in water at concentrations as low as ppm (parts per million) at very short times, and low levels consumption of reagents and energy. The main objective of this study is to implement a method for free cyanide determination in water by stripping voltammetry with standard addition in the Departmental Laboratory of Public Health of Santander using the METROHM 746 VA TRACE ANALYCER with dropping mercury electrode (DME). These parameters were identified: time of fall of the mercury drop (t. step), homogenization time (t. stirr) and pH optimum of work and the precision and accuracy of the method. The methodology followed was, first the preparation of supporting electrolyte: (c (H3BO3) =0.2 mol/L, c(KOH)=0.17 mol/L, pH=10.) and the standard solutions: (100gCN-1/L, 70gCN-1/L, 800gCN-1/L), then held the adequacy of optimum parameters of work (pH =10.5 units, t. stirr = 600 s and t. step= 0.80 s.), then were determined the values of precision and accuracy, after the calibration curve was done as a initial part of the method, finally sample was analyzed. The results obtained demonstrated the excellent accuracy and precision of the method due to its lower uncertainly values and standard deviation. We also performed the determination of cyanide in water from the California River to evaluate the technique implemented, finding the presence of cyanide in amounts greater than those allowable under Colombian law (0.05 mgCN-1/L), that due to artisanal mining located in the region. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/24180 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Voltamperometría de redisolución | |
| dc.subject | Cianuro | |
| dc.subject | Electrodo de gotas de mercurio. | |
| dc.subject.keyword | Stripping voltammetry | |
| dc.subject.keyword | Cyanide | |
| dc.subject.keyword | Dropping mercury electrode. | |
| dc.title | Implementación de la metodología para la determinación de cianuro libre en las aguas suministradas por el laboratorio departamental de salud pública mediante el método: voltamperometría de redisolución | |
| dc.title.english | Implementation of methodology for determination of free cyanide in water supplied by the public health laboratory departmental by the method: stripping voltammetry | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 1.12 MB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 1.05 MB
- Formato:
- Adobe Portable Document Format