Publicación: Formulación de un modelo de predicción de ensuciamiento de los intercambiadores de calor del tren de precalentamiento de la unidad de destilación de crudo u-2000 de la refinería de Barrancabermeja
| dc.contributor.advisor | Ramirez Caballero, Gustavo Emilio | |
| dc.contributor.author | Vera Gelvez, Carlos Alberto | |
| dc.date.accessioned | 2024-03-04T00:09:46Z | |
| dc.date.available | 2018 | |
| dc.date.available | 2024-03-04T00:09:46Z | |
| dc.date.created | 2018 | |
| dc.date.issued | 2018 | |
| dc.description.abstract | Los intercambiadores de calor son equipos diseñados para la transferencia de calor, y su mayor problema es la perdida de eficiencia debido a la acumulación de depósitos indeseados sobre su superficie de transferencia, fenómeno llamado ensuciamiento. La unidad de destilación de crudos U-2000 tiene un tren de precalentamiento diseñado para aportar el 60% de la energía necesaria para su operación, y la pérdida de transferencia de calor por ensuciamiento causa un mayor costo energético y restricciones en su capacidad de carga y producción. En este trabajo de aplicación se desarrollaron para cada intercambiador del segundo tren de precalentamiento de la U-2000 unos modelos empíricos para la predicción del ensuciamiento. Partiendo de cinco años de datos históricos de la unidad, se calculó el factor ensuciamiento de los intercambiadores (Rf) a partir del coeficiente global de transferencia (U) y la diferencia de temperatura media logarítmica (LMTD), obteniéndose así una tendencia del ensuciamiento durante su tiempo de operación. Posteriormente mediante un análisis de regresión lineal múltiple se obtuvo un modelo del factor de ensuciamiento en función del tiempo, del flujo de las corrientes fría y caliente, y la diferencia de temperatura media logarítmica, los cuales tuvieron significancia estadística con un intervalo de confianza del 95%. También se simularon de manera rigurosa los intercambiadores de calor, obteniéndose datos de su comportamiento mediante un análisis de sensibilidad, con los que se desarrollaron modelos similares a los estimados con los datos históricos. Igualmente se obtuvieron datos para estimar los costos causados por operar los intercambiadores evaluados con un alto grado de ensuciamiento. Por ultimo con los modelos empíricos de predicción de ensuciamiento obtenidos con los datos históricos, se estimó mediante una función objetivo, el tiempo en que los intercambiadores alcanzan un nivel de ensuciamiento que afecta la operación y deben iniciar su programa de limpieza. | |
| dc.description.abstractenglish | Heat exchangers are equipment designed for heat transfer, and its biggest problem is the loss of efficiency due to the accumulation of unwanted deposits on its transfer surface, a phenomenon called fouling. The U-2000 crude distillation unit has a preheating train designed to provide 60% of the energy needed for its operation, and the loss of heat transfer due to fouling causes a higher energy cost and restrictions on its feed capacity and production. In this application study, empirical models for the prediction of fouling were developed for each exchanger of the second preheating train of the U-2000. Based on five years of historical data of the unit, the fouling factor of the exchangers (Rf) was calculated from the global transfer coefficient (U) and the logarithmic mean temperature difference (LMTD), thus obtaining a tendency of fouling during its operating time. Subsequently, by means of a multiple linear regression analysis, a model of the fouling factor as a function of time, the flow of cold and hot currents, and the logarithmic mean temperature difference were obtained, which had statistical significance with a confidence interval of 95%. The heat exchangers were also rigorously simulated, obtaining data on their behavior through a sensitivity analysis, with which models similar to those estimated with historical data were developed. Likewise, data were obtained to estimate the costs caused by operating the exchangers evaluated with a high level of fouling. Finally with the empirical models of prediction of soiling obtained with the historical data, and by means of an objective function, the time in which the exchangers reach a level of contamination that affects the operation and should start its cleaning program was estimated. | |
| dc.description.degreelevel | Maestría | |
| dc.description.degreename | Magíster en Ingeniería Química | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/39067 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Maestría en Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Intercambiador De Calor | |
| dc.subject | Tren De Precalentamiento | |
| dc.subject | Transferencia De Calor | |
| dc.subject | Ensuciamiento | |
| dc.subject | Análisis De Regresión Lineal Múltiple | |
| dc.subject | Modelos Empíricos. | |
| dc.subject.keyword | Heat Exchanger | |
| dc.subject.keyword | Pre-Heating Train | |
| dc.subject.keyword | Heat Transfer | |
| dc.subject.keyword | Fouling | |
| dc.subject.keyword | Multiple Linear Regression Analysis | |
| dc.subject.keyword | Empirical Models. | |
| dc.title | Formulación de un modelo de predicción de ensuciamiento de los intercambiadores de calor del tren de precalentamiento de la unidad de destilación de crudo u-2000 de la refinería de Barrancabermeja | |
| dc.title.english | Formulation of a model of prediction of fouling of the heat exchangers of the pre-heating train of the crude oil distillation unit u-2000 of the barrancabermeja refinery* | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_bdcc | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Maestria | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 78.48 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 181.47 KB
- Formato:
- Adobe Portable Document Format