Publicación: CORRELACION ENTRE LA VARIABILIDAD DE LOS PARAMETROS DERIVADOS DE VENA CAVA INFERIOR Y LA VARIACIÓN DE PRESION DE PULSO EN PACIENTES CRÍTICOS
| dc.contributor.advisor | MELÉNDEZ FLÓREZ, HÉCTOR JULIO | |
| dc.contributor.advisor | SERRANO VÁSQUEZ, RAFAEL ENRIQUE | |
| dc.contributor.author | VILLA ACUÑA, MARÍA MÓNICA | |
| dc.contributor.evaluator | ÁLVAREZ ROBLES, SAÚL | |
| dc.contributor.evaluator | NARANJO JUNOY, FRANCISCO FERNANDO | |
| dc.date.accessioned | 2026-03-13T17:29:22Z | |
| dc.date.available | 2026-03-13T17:29:22Z | |
| dc.date.created | 2019-01-29 | |
| dc.date.issued | 2019-01-29 | |
| dc.description.abstract | Antecedentes: El monitoreo dinámico no invasivo obtenido por ecocardiografía transtorácica evalúa cambios en los parámetros derivados de la vena cava inferior (PDVCI) durante el ciclo respiratorio, con capacidad moderada para predecir respuesta a volumen (en comparación con gasto cardíaco) y de buen nivel de evidencia; La variación de presión de pulso (VPP) es el parámetro mínimamente invasivo que mejor predice respuesta a volumen después del gasto cardíaco. Actualmente no hay estudios que correlacionen directamente los PDVCI con VPP. Objetivo: Describir el coeficiente de correlación entre PDVCI y VPP en pacientes críticos, el grado de concordancia entre modo B (mB) y modo M (Mm) de los PDVCI y adicionalmente evaluar los PDVCI como prueba diagnóstica. Materiales y Métodos: Estudio analítico de evaluación de tecnología diagnóstica realizado en 80 pacientes con diagnóstico de choque, definido como hipotensión persistente con requerimiento de soporte vasopresor y/o con hiperlactatemia, de quienes se obtuvieron datos de monitoreo de VPP y PDVCI mediante ecografía en modo B y modo M, antes y después de administrar bolo de líquidos. Resultados: El índice de correlación entre VPP y PDVCI basal fue fuerte (rho 0.7 mM y 0.8 mB) y moderada a baja post-bolo. La concordancia de los PDVCI mB y mM fue baja. Adicionalmente, tomando como patrón de referencia la VPP, los PDVCI presentaron altos valores de sensibilidad, especificidad y AROC para discriminar pacientes respondedores de no respondedores, valores que disminuyeron posterior a la aplicación de bolo de líquidos. Discusión y Conclusiones: La VPP y los PDVCI presentaron correlación excelente y regular antes y después del bolo, respectivamente. La concordancia entre mB y mM fue baja. Los PDVCI deben estandarizarse y seguir evaluando su utilidad a la cabecera del paciente crítico. | |
| dc.description.abstractenglish | Background: Noninvasive dynamic monitoring by transthoracic echocardiography evaluates changes in the parameters of the inferior vena cava (LVICP) during respiratory cycle, with moderate capacity to predict the response to volume (in comparison with cardiac output) and good level of evidence; Pulse pressure variation (PPV) is the minimally invasive parameter that best predicts response to a volume after cardiac output. Currently there are no studies that directly relate the PDVCI to the PPV. Objective: To describe the correlation coefficient between PDVCI and PPV in critical patients, degree of concordance between mode B (mB) and mode M (Mm) of PDVCI and additionally to evaluate the PDVCI as a diagnostic test. Materials and Methods: Analytical study of diagnostic technology evaluation performed in 80 patients with diagnosis of shock, defined as persistent hypotension requiring vasopressor support and / or hyperlactatemia, from which was obtained VPP and PDVCI monitoring data by ultrasound in mode B and M mode, before and after applying liquid bolus. Results: Correlation index between basal VPP and PDVCI was strong (rho 0.7 mM and 0.8 mB) and moderate to low post-bolus. Concordance of mB and mM PDVCI was low. Additionally, taking VPP as the reference standard, PDVCI presented high values of sensitivity, specificity and AROC to discriminate patients responding to non-responders, values that decreased after the application of liquid bolus. Discussion and Conclusions: VPP and PDVCI presented an excellent and regular correlation before and after the bolus, respectively. The agreement between mB and mM was low. The PDVCI should be standardized and continue assessing its usefulness at the critical patient’s bedside. | |
| dc.description.degreelevel | Especialización | |
| dc.description.degreename | Especialista en Anestesiología y Reanimación | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/47382 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Salud | |
| dc.publisher.program | Especialización en Anestesiología y Reanimación | |
| dc.publisher.school | Escuela de Medicina | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Fluidoterapia | |
| dc.subject | monitorización hemodinámica | |
| dc.subject | análisis de la onda del pulso | |
| dc.subject | vena cava inferior y ecocardiografía | |
| dc.subject.keyword | Fluid therapy | |
| dc.subject.keyword | hemodynamic monitoring | |
| dc.subject.keyword | pulse wave analysis | |
| dc.subject.keyword | inferior vena cava and echocardiography | |
| dc.title | CORRELACION ENTRE LA VARIABILIDAD DE LOS PARAMETROS DERIVADOS DE VENA CAVA INFERIOR Y LA VARIACIÓN DE PRESION DE PULSO EN PACIENTES CRÍTICOS | |
| dc.title.english | CORRELATION BETWEEN THE VARIABILITY OF PARAMETERS DERIVED FROM INFERIOR VENA CAVA AND THE VARIATION OF PULSE PRESSURE IN CRITICAL PATIENTS | |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 291.54 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 253.19 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción:
