Publicación: Degradación electrolítica de recubrimientos de ácido polo l-láctico sobre sustratos ti6al4v en solución sanguínea simulada
| dc.contributor.advisor | Laverde Catano, Dionisio | |
| dc.contributor.advisor | Estupinan Duran, Hugo Armando | |
| dc.contributor.author | Boada Lopez, Jairo Andres | |
| dc.date.accessioned | 2024-03-03T16:30:45Z | |
| dc.date.available | 2007 | |
| dc.date.available | 2024-03-03T16:30:45Z | |
| dc.date.created | 2007 | |
| dc.date.issued | 2007 | |
| dc.description.abstract | Estudios sobre la aleación de Ti6Al4V, han demostrado un comportamiento mecánico que lo hace muy útil para aplicaciones médicas como implante en la reconstrucción de tejidos además de presentar una compatibilidad y resistencia a la corrosión frente a sistemas biológicos debido a la formación de una capa estable de óxido de titanio TiO2. Sin embargo esta capa presenta muy baja adherencia, dejando desprotegida la superficie de la aleación, presentándose en muchos casos, liberaciones de iones vanadio, los cuales representan un crítico nivel de citotoxicidad. Con el fin de proteger la capa de óxido, mejorar la bioactividad de las prótesis fabricadas con este material, aumentar la ploriferación celular en el proceso de osteointegración del implante y promover la obtención de soportes poiméricos a partir de PLA para la liberación controlada de fármacos, se han obtenido recubrimientos de ácido poli (L-láctico) sobre sustratos de Ti6Al4V, a los cuales se les ha realizado un estudio del mecanismo de degradación. Las pruebas de degradación han sido hechas en una solución corporal simulada (SBF) por medio de las técnicas de espectroscopia de impedancia electroquímica (EIS) y Voltametria cíclica (CV). Se hizo una comparación entre las resistencias de transferencia de carga de las distintas muestras obtenidas a diferentes condiciones de voltajes, y se seleccionó la mejor condición de resistencia para ser sometida a un análisis de degradación por inmersión en SBF por un tiempo de 8 días y por voltametria cíclica, obteniendo cuantitativamente los cambios en las constantes de transferencia de carga respecto al tiempo de degradación de la capa de PLA y el crecimiento de la capa de oxido de titanio | |
| dc.description.abstractenglish | Studies about Ti 6Al4V alloy, has demonstrated a mechanical behavior that it makes useful for medical applications, as implants in the tissues reconstruction besides presents a compatibility and resistance to the against corrosion biological systems, this due to the formation of stable film of titanium oxide TiO2. Nevertheless this layer presents very low adhesion, leaving unprotected the surface of the alloy, presented in many cases liberations vanadium ion, which represent a level of citotoxicity. With the purpose of protect this oxide film and improving the bioactivity of prostheses made of this material, increase the cellular growth in the osteointegration process of the implants and promote the construction of polymeric scaffolds from PLA for the controlled release of drugs , made poly Llactic coatings has been obtained on substrate of Ti6Al4V which they had carried out a study of the mechanism of degradation, immersed in a simulated corporal solution (SBF) by means of the techniques of electrochemical impedance spectroscopy (EIS) and cyclic voltametry (CV). A comparison between the load transference resistance of the different obtained samples from different conditions of voltages was made, and was selected the best resistance condition to put under degradation analysis by immersion in SBF by a time of 8 days and cyclic voltametry obtaining quantitative changes in the transfer charge constant for the degradation time of the PLA layer and the growth of the titanium oxidize | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/19529 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Ácido Poli L-láctico (PLA) | |
| dc.subject | Degradación electrolítica | |
| dc.subject | Espectroscopia de impedancia electroquímica | |
| dc.subject | Ti6Al4V | |
| dc.subject | Voltametría cíclica | |
| dc.subject.keyword | Biomaterial | |
| dc.subject.keyword | Cyclic voltametry | |
| dc.subject.keyword | Electrochemical impedance spectroscopy | |
| dc.subject.keyword | Polylactic acid | |
| dc.subject.keyword | Ti6Al4. | |
| dc.title | Degradación electrolítica de recubrimientos de ácido polo l-láctico sobre sustratos ti6al4v en solución sanguínea simulada | |
| dc.title.english | Electrolytic degradation of poly l-lactic coatings on ti6al4v substrates in simulated sanguineous solution. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |