Publicación: Estudio sobre el potencial de la técnica NIR como estrategia para determinar la calidad bromatológica de la carne de pollo comercial
| dc.contributor.advisor | Lopez Giraldo, Luis Javier | |
| dc.contributor.advisor | Muvdi Nova, Carlos Jesus | |
| dc.contributor.author | Suarez Castañeda, Julián David | |
| dc.contributor.author | Arguello Uribe, Maria Camila | |
| dc.contributor.evaluator | Rojas Perez, Lilia Carolina | |
| dc.contributor.evaluator | Barajas Ferreira, Crisostomo | |
| dc.date.accessioned | 2025-11-19T15:39:27Z | |
| dc.date.available | 2025-11-19T15:39:27Z | |
| dc.date.created | 2025-11-18 | |
| dc.date.issued | 2025-11-18 | |
| dc.description.abstract | En este estudio se evaluó la capacidad de entrenamiento y predicción del equipo Proximate® para ser utilizado como herramienta de control de calidad bromatológica de cárnicos avícolas en la industria de alimentos mediante la técnica de espectroscopía NIR (Near-Infrared Spectroscopy) como alternativa a los métodos tradicionales de química húmeda, que son lentos y destructivos. Las muestras utilizadas, junto con los valores de referencia de los parámetros de calidad de interés (proteína, grasa, humedad y ceniza) fueron obtenidos a través del Grupo de Investigación en Ciencia y Tecnología en Alimentos (CICTA). Se entrenó el equipo, se desarrollaron dos modelos de calibración comparables: uno realizado manualmente mediante el software externo The Unscrambler X en el que se realizó un pretratamiento a los datos espectrales mediante Multiplicative Scatter Correction (MSC), que mostró buena capacidad de predicción mediante Partial Least Squares (PLS), y otro generado directamente por el equipo ProxiMate®, con menor desempeño debido al reducido número de muestras para calibración. Finalmente, para determinar la capacidad predictiva del equipo se realizaron lecturas a muestras independientes de la calibración, obteniendo así valores de Determination coefficient (𝑅2) de 0,85; 0,88; 0,86 y 0,68; Root mean square error in prediction (𝑅𝑀𝑆𝐸𝑃) de 1,045; 1,667; 1,230 y 0,225 y Ratio of prediction to deviation 𝑅𝑃𝐷 2,306; 2,144; 2,150 y 1,469 para proteína, grasa, humedad y ceniza respectivamente. El equipo, según el parámetro de confiabilidad RPD presentó un modelo predictivo aplicable. Sin embargo, el modelo del software evidencia mayor potencial de la técnica NIR como apoyo para el control bromatológico con la incorporación de nuevas muestras al equipo que fortalezcan el modelo, mejorando la precisión y confiabilidad según la métrica RPD. | |
| dc.description.abstractenglish | This study evaluated the training and prediction capability of the Proximate® device for use as a tool in bromatological quality control of poultry meat products in the food industry through Near-Infrared Spectroscopy (NIR) as an alternative to traditional wet chemistry methods, which are slow and destructive. The samples, along with reference values for quality parameters of interest (protein, fat, moisture, and ash), were provided by the Food Science and Technology Research Group (CICTA). The device was trained, and two comparable calibration models were developed: one manually created using external software The Unscrambler X, where spectral data were preprocessed by Multiplicative Scatter Correction (MSC) and Partial Least Squares (PLS) regression demonstrated good prediction capability; and another generated directly by the Proximate® device, which showed lower performance due to a limited number of calibration samples. Finally, to determine the predictive ability of the device, independent samples outside the calibration set were tested, yielding coefficients of determination (𝑅²) of 0.85, 0.88, 0.86, and 0.68; root mean square errors of prediction (RMSEP) of 1.045, 1.667, 1.230, and 0.225; and ratios of prediction to deviation (RPD) of 2.306, 2.144, 2.150, and 1.469 for protein, fat, moisture, and ash, respectively. According to the RPD reliability parameter, the device produced an applicable predictive model. However, the software-generated model demonstrates greater potential of the NIR technique as support for bromatological control with the incorporation of additional samples to strengthen the model, improving precision and reliability according to the RPD metric. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/46570 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
| dc.publisher.program | Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Espectroscopía | |
| dc.subject | NIR | |
| dc.subject | PLS | |
| dc.subject | Bromatología | |
| dc.subject | Pollo | |
| dc.subject | The Unscrambler X | |
| dc.subject.keyword | Spectroscopy | |
| dc.subject.keyword | NIR | |
| dc.subject.keyword | PLS | |
| dc.subject.keyword | Bromatology | |
| dc.subject.keyword | Chicken | |
| dc.subject.keyword | The Unscrambler X | |
| dc.title | Estudio sobre el potencial de la técnica NIR como estrategia para determinar la calidad bromatológica de la carne de pollo comercial | |
| dc.title.english | Study on the potential of the NIR technique as a strategy to determine the bromatological quality of commercial chicken meat | |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 104.1 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 90.32 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción:
