Publicación: Análisis de la calidad de sal de mesa, consumida en el departamento de Santander, usando parámetros fisicoquímicos: flúor y yodo
| dc.contributor.advisor | Sánchez Torres, Viviana | |
| dc.contributor.advisor | Bayona Vergel, Sandra | |
| dc.contributor.author | Izquierdo Quintero, Javier Eduardo | |
| dc.date.accessioned | 2023-04-06T14:46:43Z | |
| dc.date.available | 2023 | |
| dc.date.available | 2023-04-06T14:46:43Z | |
| dc.date.created | 2019 | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Gracias al frecuente consumo de sal de cocina, se hicieron estudios acerca de su fortificación, para la prevención de enfermedades tales como el bocio y la caries dental que son causados por deficiencia de micronutrientes. A partir de la creación en el año 1993 del Instituto Nacional de Vigilancia de Medicamentos y Alimentos (INVIMA) y la expedición del decreto 547 de 1996, es importante contar con un método eficaz para la regulación de las concentraciones de micronutrientes como el yodo y el flúor en la sal de mesa. Es competencia del Laboratorio Departamental de Salud Pública (LDSP) de Santander llevar a cabo la cuantificación de los micronutrientes ya mencionados. Es por esto que el laboratorio decidió implementar el método de ion selectivo desarrollado por el INVIMA (Velasquez, 1997), para realizar la medición de la concentración de flúor y yodo en las sales de mesa que se consumen en el departamento de Santander. Se evaluó el método mediante las siguientes figuras de mérito: linealidad, exactitud y precisión. Los resultados obtenidos fueron satisfactorios, para la linealidad se obtuvo un R²=0.9993 para flúor y R²=0.9998 para yodo; la exactitud se comprobó calculando los porcentajes de recuperación (R%), los cuales estuvieron en el rango de 60 %- 80%; la precisión se constató con el coeficiente de variación (%CV) los cuales fueron menores al 5%.Lo anterior confirma que es un método confiable para la emisión de resultados. Se realizó el análisis de muestras de sal , de 7 diferentes marcas recogidas por el área de salud ambiental perteneciente al Ministerio de Salud y Protección Social, para determinar la calidad de la sal en cuanto a parámetros fisicoquímicos flúor y yodo, el cual dió como resultado que el 40% de las sales no cumplen con el rango de concentración de flúor o yodo fijado por ley (180 ppm-220 ppm flúor; 50 ppm – 100 ppm yodo) y una concentración promedio para flúor de 188.996 ± 45.583 ppm y para yodo de 60.084 ± 9.779 ppm. | |
| dc.description.abstractenglish | Thanks to the frequent consumption of table salt, studies were made about its fortification, for the prevention of diseases such as goiter and tooth decay that are caused by micronutrient deficiency. From the creation in 1993 of the National Institute for Food and Drug Surveillan (INVIMA) and the issuance of Decree 547 of 1996, it is important to have an effective method for the regulation of micronutrient concentrations such as iodine and fluorine in table salt. It is the responsibility of the Departmental Laboratory of Public Health (LDSP) of Santander to carry out the quantification of the micronutrients already mentioned Reason for because laboratory decided to implement the selective ion method developed by INVIMA (Velasquez, 1997), to measure the concentration of fluorine and iodine in the table salts consumed in the department of Santander. The method was evaluated by the following figures of merit: linearity, accuracy and precision. The results obtained were satisfactory, for linearity was obtained an R² = 0.9993 for fluorine and R² = 0.9998 for iodine; the accuracy was checked by calculating the recovery percentages (R%), which were in the range of 60% -80%; The accuracy was checked by the coefficient of variation (% CV) which were less than 5%. The above confirms that it is a reliable method for issuing results. The analysis of salt samples, from 7 different brands collected by the environmental health area belonging to the Ministry of Health and Social Protection. For performed to determine the quality of the salt in term of fluorine and iodine physicochemical parameters, which resulted in that 40% of salts do not comply the fluorine or iodine concentration range set by law (180 ppm-220 ppm fluorine; 50 ppm - 100 ppm iodine) and an average concentration for fluorine of 188,996 ± 45,583 ppm and for iodine 60,084 ± 9,779 ppm. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/13787 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.title | Análisis de la calidad de sal de mesa, consumida en el departamento de Santander, usando parámetros fisicoquímicos: flúor y yodo | |
| dc.title.english | Analysis of the quality of table salt, consumed in the department of Santander, using physicochemical parameters: fluorine and iodine | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Documento.pdf
- Tamaño:
- 643.33 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 190.86 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 133.55 KB
- Formato:
- Adobe Portable Document Format
