Publicación: Implementación del método voltamperometrico de redisolución anódica con electrodo de oro para la determinación de mercurio en agua potable en el laboratorio departamental de salud pública de Santander
| dc.contributor.advisor | Blanco Rios, Freddy Andres | |
| dc.contributor.author | Zarate Acevedo, Edgar | |
| dc.contributor.author | Mendoza Bottia, Jorge | |
| dc.date.accessioned | 2024-03-03T17:29:09Z | |
| dc.date.available | 2009 | |
| dc.date.available | 2024-03-03T17:29:09Z | |
| dc.date.created | 2009 | |
| dc.date.issued | 2009 | |
| dc.description.abstract | Durante los últimos años se han venido desarrollando técnicas analíticas para la determinación de mercurio, las cuales confieren la posibilidad de disminuir el consumo tanto energético como de reactivos. Una de las mejores alternativas para la determinación de mercurio es la voltamperometría de redisolución anódica, que nos permite cuantificar mercurio alcanzando valores hasta de partes por trillón (ppt) durante tiempos de análisis relativamente cortos, sin la necesidad de pretratamientos de la muestra y utilizando cantidades de energía y reactivos mínimas. En el presente estudio se conto con la posibilidad de trabajar en la determinación de mercurio en agua potable con la ayuda del Laboratorio Departamental de Salud Publica de Santander utilizando el equipo voltamperométrico Metrohm 746 VA Trace Analyzer acoplado al instrumento 746 VA Stand. El objetivo principal de este proyecto es implementar un método voltamperométrico de redisolución anódico con adición de dos soluciones estándar que permita la determinación de mercurio en agua potable de una manera eficiente, por tanto se determinaron los principales parámetros (tiempo de electrodeposición, electrolito soporte, Voltaje de oxidación, volumen de la muestra, volumen de adición estándar). La metodología experimental comenzó con la selección del electrolito soporte obteniéndose la siguiente solución: 400µL de Na2EDTA 2H2O de 0,1mol/L, 300µL de Acido Perclórico (HCLO4) y 1mL de Cloruro de Sodio (NaCl). Seguidamente se realizaron pruebas voltamperométricas para la determinación del Voltaje al cual el mercurio se oxida en presencia del electrolito mencionado. Posteriormente se determinó el tiempo de electrodeposición optimo prudente para el análisis de las muestras. Finalmente se obtuvo el volumen y concentración de solución estándar de mercurio a adicionar. De los resultados se pudo obtener las siguientes características para el método voltamperométrico: Electrolito soporte 400µL de Na2EDTA 2H2O de 0,1mol/L, 300µL de Acido Perclórico (HCLO4 ) y 1mL de Cloruro de Sodio (NaCl), voltaje de oxidación del mercurio 620mV, Volumen de la muestra de 10mL,Volumen de solución Estándar 100µL de concentración 1mg/L y tiempo de electrodeposición de 700 segundos. | |
| dc.description.abstractenglish | During the past few years they have come developing technical analytical for the determination of mercury, which confer the possibility to diminish the energy consumption as well as reagents. One of the best alternatives for the mercury determination is the Anodic Stripping Voltammetry, that allows us to quantify mercury reaching values to of parts per trillion (ppt) during times of relatively short analyses, without the necessity of pretreatment of the sample and using minimum amounts of energy and reagents. The present study had the possibility of working in the mercury determination in potable water with the Departmental Public Health Laboratory of Santander using the voltammertric equipment Metrohm 746 VA Trace Analyzer connected to instrument 746 VA Stand. The primary target of this project is to implement voltammetric method of anodic stripping with addition of two standard solutions that allows the potable water mercury determination of an efficient way, therefore determined the main parameters (time of deposition, supporting electrolyte, Voltage of reduction, volume of the sample, volume of standard addition). The experimental methodology began with the selection of the supporting electrolyte what obtained the following solution: 400µL of Na2EDTA 2H2O of 0,1mol/L, 300µL of Percloric Acid (HCLO4) and 1mL of Sodium chloride (NaCl). Next voltammetrics tests were realized for the determination of the Voltage to which mercury is oxidized in the presence of the mentioned electrolyte. Later the time of prudent optimum deposition for the analysis of the samples was determined. Finally was obtained the volume and concentration of mercury standard solution to add. From the results it was possible to be obtained the following characteristics for the voltammetry method: Supporting Electrolyte 400µL of Na2EDTA 2H2O of 0,1mol/L, 300µL of Percloric Acid (HCLO4) and 1mL of Sodium chloride (NaCl), voltage oxidized of mercury 620mV, sample volume of 10mL, standard solution volume 100µL of concentration 1mg/L and time of deposition 700 seconds. | |
| dc.description.degreelevel | Pregrado | |
| dc.description.degreename | Ingeniero Químico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/22014 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
| dc.publisher.program | Ingeniería Química | |
| dc.publisher.school | Escuela de Ingeniería Química | |
| dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
| dc.subject | Voltamperometría | |
| dc.subject | Redisolución Anódica | |
| dc.subject | Metrohm | |
| dc.subject | Laboratorio Departamental de Salud Pública | |
| dc.subject | Mercurio | |
| dc.subject | Agua Potable. | |
| dc.subject.keyword | Voltammetry | |
| dc.subject.keyword | Anodic Stripping | |
| dc.subject.keyword | Metrohm | |
| dc.subject.keyword | Laboratory Departmental of Health Public | |
| dc.subject.keyword | Mercury | |
| dc.subject.keyword | Potable water. | |
| dc.title | Implementación del método voltamperometrico de redisolución anódica con electrodo de oro para la determinación de mercurio en agua potable en el laboratorio departamental de salud pública de Santander | |
| dc.title.english | Implementation of anodic stripping voltammetry method with gold electrode for the mercury determination in potable water in departmental laboratory of public health of santander. | |
| dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
| dspace.entity.type | Publication |