Logotipo del repositorio

Publicación:
Implementación del método voltamperometrico de redisolución anódica con electrodo de oro para la determinación de mercurio en agua potable en el laboratorio departamental de salud pública de Santander

dc.contributor.advisorBlanco Rios, Freddy Andres
dc.contributor.authorZarate Acevedo, Edgar
dc.contributor.authorMendoza Bottia, Jorge
dc.date.accessioned2024-03-03T17:29:09Z
dc.date.available2009
dc.date.available2024-03-03T17:29:09Z
dc.date.created2009
dc.date.issued2009
dc.description.abstractDurante los últimos años se han venido desarrollando técnicas analíticas para la determinación de mercurio, las cuales confieren la posibilidad de disminuir el consumo tanto energético como de reactivos. Una de las mejores alternativas para la determinación de mercurio es la voltamperometría de redisolución anódica, que nos permite cuantificar mercurio alcanzando valores hasta de partes por trillón (ppt) durante tiempos de análisis relativamente cortos, sin la necesidad de pretratamientos de la muestra y utilizando cantidades de energía y reactivos mínimas. En el presente estudio se conto con la posibilidad de trabajar en la determinación de mercurio en agua potable con la ayuda del Laboratorio Departamental de Salud Publica de Santander utilizando el equipo voltamperométrico Metrohm 746 VA Trace Analyzer acoplado al instrumento 746 VA Stand. El objetivo principal de este proyecto es implementar un método voltamperométrico de redisolución anódico con adición de dos soluciones estándar que permita la determinación de mercurio en agua potable de una manera eficiente, por tanto se determinaron los principales parámetros (tiempo de electrodeposición, electrolito soporte, Voltaje de oxidación, volumen de la muestra, volumen de adición estándar). La metodología experimental comenzó con la selección del electrolito soporte obteniéndose la siguiente solución: 400µL de Na2EDTA 2H2O de 0,1mol/L, 300µL de Acido Perclórico (HCLO4) y 1mL de Cloruro de Sodio (NaCl). Seguidamente se realizaron pruebas voltamperométricas para la determinación del Voltaje al cual el mercurio se oxida en presencia del electrolito mencionado. Posteriormente se determinó el tiempo de electrodeposición optimo prudente para el análisis de las muestras. Finalmente se obtuvo el volumen y concentración de solución estándar de mercurio a adicionar. De los resultados se pudo obtener las siguientes características para el método voltamperométrico: Electrolito soporte 400µL de Na2EDTA 2H2O de 0,1mol/L, 300µL de Acido Perclórico (HCLO4 ) y 1mL de Cloruro de Sodio (NaCl), voltaje de oxidación del mercurio 620mV, Volumen de la muestra de 10mL,Volumen de solución Estándar 100µL de concentración 1mg/L y tiempo de electrodeposición de 700 segundos.
dc.description.abstractenglishDuring the past few years they have come developing technical analytical for the determination of mercury, which confer the possibility to diminish the energy consumption as well as reagents. One of the best alternatives for the mercury determination is the Anodic Stripping Voltammetry, that allows us to quantify mercury reaching values to of parts per trillion (ppt) during times of relatively short analyses, without the necessity of pretreatment of the sample and using minimum amounts of energy and reagents. The present study had the possibility of working in the mercury determination in potable water with the Departmental Public Health Laboratory of Santander using the voltammertric equipment Metrohm 746 VA Trace Analyzer connected to instrument 746 VA Stand. The primary target of this project is to implement voltammetric method of anodic stripping with addition of two standard solutions that allows the potable water mercury determination of an efficient way, therefore determined the main parameters (time of deposition, supporting electrolyte, Voltage of reduction, volume of the sample, volume of standard addition). The experimental methodology began with the selection of the supporting electrolyte what obtained the following solution: 400µL of Na2EDTA 2H2O of 0,1mol/L, 300µL of Percloric Acid (HCLO4) and 1mL of Sodium chloride (NaCl). Next voltammetrics tests were realized for the determination of the Voltage to which mercury is oxidized in the presence of the mentioned electrolyte. Later the time of prudent optimum deposition for the analysis of the samples was determined. Finally was obtained the volume and concentration of mercury standard solution to add. From the results it was possible to be obtained the following characteristics for the voltammetry method: Supporting Electrolyte 400µL of Na2EDTA 2H2O of 0,1mol/L, 300µL of Percloric Acid (HCLO4) and 1mL of Sodium chloride (NaCl), voltage oxidized of mercury 620mV, sample volume of 10mL, standard solution volume 100µL of concentration 1mg/L and time of deposition 700 seconds.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/22014
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectVoltamperometría
dc.subjectRedisolución Anódica
dc.subjectMetrohm
dc.subjectLaboratorio Departamental de Salud Pública
dc.subjectMercurio
dc.subjectAgua Potable.
dc.subject.keywordVoltammetry
dc.subject.keywordAnodic Stripping
dc.subject.keywordMetrohm
dc.subject.keywordLaboratory Departmental of Health Public
dc.subject.keywordMercury
dc.subject.keywordPotable water.
dc.titleImplementación del método voltamperometrico de redisolución anódica con electrodo de oro para la determinación de mercurio en agua potable en el laboratorio departamental de salud pública de Santander
dc.title.englishImplementation of anodic stripping voltammetry method with gold electrode for the mercury determination in potable water in departmental laboratory of public health of santander.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
519.62 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
1.76 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
283.42 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031