Logotipo del repositorio

Publicación:
Estudio de la integración de una torre absorbedora al sistema de aminas de orthoflow de la grb, para la remoción de H2S de corrientes con alto contenido de H2

dc.contributor.advisorPedraza Avella, Julio Andrés
dc.contributor.advisorGrandas Vargas, Ricardo
dc.contributor.authorSerrano Jaimes, Maria Carolina
dc.contributor.authorUribe Chacon, Oscar Daniel
dc.date.accessioned2024-03-04T00:08:58Z
dc.date.available2018
dc.date.available2024-03-04T00:08:58Z
dc.date.created2018
dc.date.issued2018
dc.description.abstractEl desarrollo de procesos de Hidrotratamiento e Hidrocraqueo, demanda flujos mayores de H2 a la capacidad de producción de la Refinería de Barrancabermeja. Ante esta situación, se identificó un H2 potencial contenido en las corrientes de proceso que van a la red de gas combustible; la recuperación del H2 de estas corrientes se dificulta debido a la alta concentración de componentes ácidos. Por lo tanto, se planteó la posibilidad del pretramiento de estas corrientes mediante absorción química para la remoción de componentes ácidos. El esquema de proceso propuesto implica la utilización de una torre absorbedora y su acople al sistema de aminas de Orthoflow existente en la refinería. Se evaluó su eficiencia y capacidad operacional del sistema instalado; de la torre a implementar, de manera independiente y posteriormente se evaluó el sistema acoplado, lo anterior mediante la herramienta de simulación de procesos Aspen Hysys V10. Se validó el paquete termodinámico seleccionado mediante el cotejo con los datos de planta y los arrojados por el simulador, concluyendo que el sistema existente presenta limitaciones hidráulicas en el proceso de regeneración de aminas, además se encontró que la torre propuesta como absorbedora cumple su función de manera satisfactoria, sin embargo, para el acople de esta torre al sistema existente, es necesario realizar un aumento del flujo de amina. Este aumento se ve reflejado en una disminución de la eficiencia en la regeneración y absorción. Por lo cual en este trabajo se recomendó un ajuste operacional que permite la eficiente integración de la torre al sistema existente; disminuyendo las limitaciones hidráulicas anteriormente mencionadas.
dc.description.abstractenglishThe development of Hydrotreating and Hydrocracking processes demands higher flows of H2 than the production capacity of the Barrancabermeja Refinery. Because of this situation, a potential H2 contained in the process streams that integrate the fuel gas network was identified. The recovery of H2 from these streams is difficult due to the high concentration of acid components. Therefore, the possibility of pretraining these streams through chemical absorption for the removal of acidic components was considered. The proposed process scheme involves the use of an absorber tower and its connection to the existing Orthoflow amines system in the refinery. The hydraulic and operational performance of the installed system was evaluated, as so was the tower to be implemented independently and subsequently the integrated system was evaluated. The evaluation was achieve using the process simulation tool Aspen Hysys V10. The selected thermodynamic package was validated through the comparison with the plant data and those given by the simulator, concluding that the existing system has hydraulic limitations in the amine regeneration process. And it was found that the tower proposed as an absorber fulfills its function. However, for the connection of this tower to the existing system, it is necessary to increase the amine flow. This increase is reflected in a decrease in efficiency in regeneration and absorption processes. Therefore, in this work an operational adjustment was recommended that allows the efficient integration of the tower to the existing system; decreasing the hydraulic limitations mentioned before.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/39049
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectAbsorción Química
dc.subjectHidráulica En Torres
dc.subjectGas Combustible
dc.subjectSimulación De Procesos
dc.subjectH2S.
dc.subject.keywordHydraulics
dc.subject.keywordFuel Gas
dc.subject.keywordProcess Simulation
dc.subject.keywordH2S.
dc.titleEstudio de la integración de una torre absorbedora al sistema de aminas de orthoflow de la grb, para la remoción de H2S de corrientes con alto contenido de H2
dc.title.englishStudy of the integration of an absorbing tower to the orthoflow amine system of the grb, for the removal of h2s from streams with high content of h2.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.typePublication

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Carta de autorización.pdf
Tamaño:
740.71 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Documento.pdf
Tamaño:
2.03 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
Nota de proyecto.pdf
Tamaño:
319.41 KB
Formato:
Adobe Portable Document Format

VIGILADA MINEDUCACIÓN

Ordenanza No. 83 de 1.944 (junio 22)

Carácter académico: Universidad

Notificaciones judiciales: notjudiciales@uis.edu.co 

.

Código SNIES: 1204   Nit: 890.201.213-4

Línea Anticorrupción:  +57 (601) 562 9300 EXT: 3633

Línea transparente: +57 (607) 630 3031