Práctica empresarial en ACIEND S.A.S como apoyo área de ensayos no destructivos en el desarrollo de procedimientos de calibración para equipos de ultrasonido por arreglo de fases (Phased Array)
dc.contributor.advisor | Galán Pinilla, Carlos Andrés | |
dc.contributor.advisor | Acevedo Acuña, Luis Alberto | |
dc.contributor.author | Vélez Peña, Omar Andrés | |
dc.contributor.evaluator | Peréz Ceballos, Ana María | |
dc.contributor.evaluator | Peña Ballesteros, Darío Yesid | |
dc.date.accessioned | 2023-11-16T12:56:16Z | |
dc.date.available | 2023-11-16T12:56:16Z | |
dc.date.created | 2023-11-14 | |
dc.date.issued | 2023-11-14 | |
dc.description.abstract | Los Ensayos No Destructivos (END) desempeñan un papel importante en la preservación de la integridad de materiales y componentes en la industria. En este contexto, los equipos de ultrasonido por Phased Array, representan una tecnología avanzada que ha revolucionado la forma en que se realizan las inspecciones. Estos sistemas ofrecen ventajas notables en términos de versatilidad y precisión en la detección de defectos en comparación con los métodos tradicionales de ultrasonido. El objetivo principal fue contribuir al mejoramiento de la precisión y eficiencia de los procedimientos de calibración utilizados en la inspección mediante Phased Array. La práctica empresarial comprendió varias etapas clave. En primer lugar, se realizó una revisión exhaustiva de la documentación técnica y se evaluaron las normativas relevantes para comprender los requisitos y estándares en el campo de los END. Luego, se llevaron a cabo actividades prácticas que incluyeron la adquisición de datos de calibración en situaciones reales de inspección y un análisis en profundidad de los resultados obtenidos. Uno de los logros destacados de esta práctica fue la identificación de factores críticos que afectan la calidad de la calibración en equipos, esto implicó el análisis de las señales ultrasónicas registradas para identificar y caracterizar posibles defectos o discontinuidades en los materiales. Se desarrollaron recomendaciones específicas para abordar y mejorar la precisión de los procedimientos de calibración. Esta práctica empresarial proporcionó una valiosa contribución a la empresa ACIEND, al suministrar una base sólida para mejorar la calibración de equipos de ultrasonido y la interpretación de las datas para la detección de defectos. Los conocimientos adquiridos en esta experiencia tienen un impacto directo en la calidad y precisión de las inspecciones, lo que es esencial para garantizar la seguridad y calidad. | |
dc.description.abstractenglish | Non-Destructive Testing (NDT) plays an important role in preserving the integrity of materials and components in industry. In this context, Phased Array ultrasound equipment represents an advanced technology that has revolutionized the way inspections are carried out. These systems offer notable advantages in terms of versatility and accuracy in detecting defects compared to traditional ultrasound methods. The main objective was to contribute to the improvement of the precision and efficiency of the calibration procedures used in Phased Array inspection. The business practice involved several keystages. Firstly, a comprehensive review of the technical documentation was carried out and the relevant regulations were evaluated to understand the requirements and standards in the field of NDT. Then, practical activities were carried out that included the acquisition of calibration data in real inspection situations and an in-depth analysis of the results obtained. One of the notable achievements of this practice was the identification of critical factors that affect the quality of calibration in equipment, this involved the analysis of the recorded ultrasonic signals to identify and characterize possible defects or discontinuities in the materials. Specific recommendations were developed to address and improve the accuracy of calibration procedures. This business practice provided a valuable contribution to the ACIEND company, by providing a solid foundation to improve the calibration of ultrasound equipment and the interpretation of data for the detection of defects. The knowledge acquired in this experience has a direct impact on the quality and accuracy of inspections, which is essential to ensure safety and quality. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Metalúrgico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/15397 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
dc.publisher.program | Ingeniería Metalúrgica | |
dc.publisher.school | Escuela de Ingeniería Metalúrgica y Ciencia de Materiales | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Calibración Phased Array | |
dc.subject | Ensayos no Destructivos | |
dc.subject | Defectología en soldaduras | |
dc.subject | Ultrasonido Phased Array | |
dc.subject.keyword | Phased Array Calibration | |
dc.subject.keyword | Non-Destructive Testing | |
dc.subject.keyword | Weld Defectology | |
dc.subject.keyword | Phased Array Ultrasound | |
dc.title | Práctica empresarial en ACIEND S.A.S como apoyo área de ensayos no destructivos en el desarrollo de procedimientos de calibración para equipos de ultrasonido por arreglo de fases (Phased Array) | |
dc.title.english | Business internship at ACIEND S.A.S as support in the non-destructive testing area in the development of calibration procedures for phased array ultrasound equipment | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Nota de proyecto..pdf
- Size:
- 168.42 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de autorización..pdf
- Size:
- 125.25 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: