Implementación de la prueba de potencial electroquímico para la determinación de la eficiencia de membrana mediante correlación con la selectividad iónica en rocas arcillosas
dc.contributor.advisor | Mejía Ospino, Enrique | |
dc.contributor.advisor | Orozco Orozco, Sergio | |
dc.contributor.author | Villabona Camacho, Jhoao Alexander | |
dc.date.accessioned | 2024-03-03T17:40:26Z | |
dc.date.available | 2009 | |
dc.date.available | 2024-03-03T17:40:26Z | |
dc.date.created | 2009 | |
dc.date.issued | 2009 | |
dc.description.abstract | En la presente investigación se implementó la prueba de potencial electroquímico para la determinación de la eficiencia de membrana mediante correlación con la selectividad iónica en muestras de rocas arcillosas. Las muestras usadas en el análisis corresponden a rocas de diversos pozos colombianos de interés geológico como el Castilla Norte 33, el Petrolea 224 y el Liria YZ-10. Las muestras fueron caracterizadas mediante difracción de rayos X (DRX), permeabilidad (k) y capacidad de intercambio catíonico (CIC). Los resultados de este estudio muestran los valores de selectividad iónica (SI) de diversas muestras de rocas arcillosas. La evaluación del efecto del tipo y de la concentración de sal sobre estos valores y la evaluación de la relación entre los valores de SI y propiedades de la roca tales como la composición mineralógica, la k y la CIC. Las soluciones de NaCl con actividades de 0,85 y 0,93 generaron los valores más altos de SI en todas las muestras analizadas. Los valores de SI tienen una relación directamente proporcional con la k y la CIC. Los valores de SI variaron entre 3,1 % y 76,7 %. Las muestras del pozo Liria YZ-10 (10700,27 pies) y del pozo Petrolea 224 (1302,71 pies) mostraron los mayores valores de SI. La muestra obtenida del pozo Petrolea 224 (1062,33 pies) presentó los menores valores de SI con las diversas combinaciones de sal y concentración, los cuales estuvieron por debajo de los límites de detección con las soluciones de CaCl2. Finalmente, fueron determinados los valores de eficiencia de membrana (EM) mediante correlación con los valores de SI a través de ecuaciones de líneas de tendencia de datos de literatura para cada una de las muestras. Los valores de EM variaron entre 0,3 % y 3,5 %. La muestra obtenida del pozo Liria YZ-10 presento los mayores valores de EM con soluciones de CaCl2 0,93 y de NaCl 0,85. El comportamiento de los valores de SI es el mismo presentado por la EM, de tal forma que el aumento de la SI implica el aumento de la EM. Los bajos valores obtenidos de EM permiten proponer la realización de un estudio donde se usen emulsiones que conlleven al aumento de la fase oleosa y por consiguiente de los valores de EM. | |
dc.description.abstractenglish | In the present investigation the electrochemical potential test was implemented for determination of the membrane efficiency by means of correlation with the ionic selectivity on samples of loamy rocks. Samples used in the analysis correspond to rocks of several Colombian wells of geologic interest as Castilla Norte 33, Petrolea 224 and Liria YZ-10. Samples were characterized by means of rays X diffraction (RXD), permeability (k) and cationic exchange capacity (CEC). Results of this study showes the values of ionic selectivity (IS) of several samples of loamy rocks. The evaluation of the effect of the type and the concentration of salt on these values and also the evaluation of the relationship between the IS values and properties of the rock such as the mineralogical composition, the k and the CEC. The solutions of NaCl with activities of 0,85 and 0,93 generated the highest values of IS in all the analyzed samples. The values of IS have a direct proportional relationship with the k and the CEC. The values of IS varied between 3,1 % and 76,7 %. The samples of the well Liria YZ-10 (10700,27 feet) and of the well Petrolea 224 (1302,71 feet) showed the highest values of IS. The obtained sample of the well Petrolea 224 (1062,33 feet) presented the lowest values of IS with the diverse combinations of salt and concentration, which were below the detection limits with the solutions of CaCl2. Finally, the values of membrane efficiency were determined (ME) by means of correlation with the values of IS with the use of equations of lines of tendency of literature data, for each one of the samples. Thus the values of ME varied between 0,3 % and 3,5 %. The obtained sample of the well Liria YZ-10 presents the highest values in ME with solutions of CaCl2 0,93 and of NaCl 0,85. The behavior of the values of IS are the same ones presented by the ME, in such a way that the increase of the IS implies the increase of the ME. The low obtained values of ME allow to propose that the study can be carried out using emulsions that permits the increase of the oleaginous phase and consequently the increase of the values of ME. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Químico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/23080 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ciencias | |
dc.publisher.program | Química | |
dc.publisher.school | Escuela de Química | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Eficiencia de membrana | |
dc.subject | Selectividad iónica | |
dc.subject | Prueba de potencial electroquímico | |
dc.subject | Estabilidad de pozo | |
dc.subject | Interacción química | |
dc.subject | ósmosis | |
dc.subject | rocas arcillosas | |
dc.subject | actividad acuosa. | |
dc.subject.keyword | Membrane efficiency | |
dc.subject.keyword | Ionic selectivity | |
dc.subject.keyword | Electrochemical potential test | |
dc.subject.keyword | Wellbore stability | |
dc.subject.keyword | Chemical interaction | |
dc.subject.keyword | osmosis | |
dc.subject.keyword | loamy rocks | |
dc.subject.keyword | watery activity. | |
dc.title | Implementación de la prueba de potencial electroquímico para la determinación de la eficiencia de membrana mediante correlación con la selectividad iónica en rocas arcillosas | |
dc.title.english | Implementation of the electrochemical potential test for the determination of the efficiency of membrane by means of correlation with the ionic selectivity in loamy rocks | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 68.59 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 40.15 KB
- Format:
- Adobe Portable Document Format