Implante de lentes faquicos de cámara anterior (artisan°) para pacientes con ametropías altas en el Centro Oftalmológico Virgilio Galvis
dc.contributor.advisor | Tello Hernandez, Alejandro | |
dc.contributor.author | Espinoza Garcia, Juan Vicente | |
dc.date.accessioned | 2024-03-03T16:43:39Z | |
dc.date.available | 2007 | |
dc.date.available | 2024-03-03T16:43:39Z | |
dc.date.created | 2007 | |
dc.date.issued | 2007 | |
dc.description.abstract | Objetivo: Describir los resultados post-quirúrgicos de pacientes miopes e hipermétropes altos a quienes se les implanto lentes fáquicos de cámara anterior tipo ARTISAN®, con un seguimiento post-operatorio entre 6 meses y 4 o mas años (1998 Œ 2007). Diseño del estudio: Estudio retrospectivo. Abril de 1998 hasta Julio del 2007. Métodos: Se revisó el tipo y magnitud de ametropía preoperatorio, variables como agudeza visual sin corrección ( AVSC ), agudeza visual con corrección ( AVCC ) , profundidad de cámara anterior ( ACD ) , densidad de células endoteliales ( ECD ) y poder del lente intraocular ( LIO ) . Se midieron las anteriores variables luego del implante, en cada periodo post-operatorio (POP), analizándose el porcentaje de perdida de células endoteliales, perdida y ganancia de líneas de visión, efectividad, seguridad y predictibilidad del LIO asociado o no a Bioptica. Resultados: Se identificaron 140 ojos, de pacientes con edad 33,56/8,3 años, equivalente esférico (SE) -11,83/6,88 D (dioptrías), ACD de 3,21/0,29 mm y ECD de 2605,8/325,1 cel/mm². El 33% (46 ojos), tenían defectos mayores de -15 D. El 35% presento AVCC de 20/30 a los 4 años POP, en ese periodo el 98,45% tuvo un SE dentro de +/-1,5 D; se observo una perdida de ECD de 13,24%, el 1,6% de los ojos presento perdida de dos o mas líneas de visión y un 32,2% obtuvo ganancia de 2 o mas líneas de visión. Todos los ojos con Bioptica presentaron un SE menor de 0,25 D. El 2,85% de los ojos presento subluxacion espontánea del lente; y únicamente 10 ojos requirieron un procedimiento adicional del total de ojos implantados. Conclusiones: El implante de ARTISAN®, cumple con las expectativas de seguridad, predictibilidad, efectividad y estabilidad. Los resultados obtenidos con Bioptica nos demuestran ser una herramienta importante para mejorar resultados refractivos de forma segura. | |
dc.description.abstractenglish | Purpose: Describe the post-operative results of patients with high myopia and hyperopia, that was implanted anterior chamber lens (ARTISAN®), with a postoperative follow-up between 6 month and 4 or more years (1998 to 2007). Study design: Retrospective case review April 1998-July 2007. Methods: To review the kind and magnitude of preoperative ametropy, items like uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), anterior chamber diameter (ACD), endothelial cell density (ECD) and power of intraocular lens (IOL). Measure the items after the implant, in each post-operative period (POP). Analyzing the endothelial cell loss percent, loss and gain of Snellen visual lines, effectiveness, security and predictability of the IOL alone and associate to Bioptic procedure. Results: A total of 140 eyes were identified, the age patients was 33,56/8,3 years, espheric equivalent (SE) -11,83/6,88 D ( Diopters), ACD of 3,21/0,29 mm and ECD of 2605,8/325,1 cell/mm². The 33% (46 eyes) had defects greater than -15.0 D. At 4 years, 35% of all eyes were with 20/30 of BCVA, in that period 98,45% were with SE within 1,5 D, loss of ECD was 13,24%; 1,6% lost 2 or more lines of BCVA and 32% gained 2 or more visual lines. Eyes with Bioptic reach less of 0, 25 D of SE. 2, 85% of eyes show spontaneous subluxation of the IOL; and only 10 eyes require an additional procedure of total eyes with IOL implant. Conclusion: Implantation of ARTISAN® has reached expectations of security, predictability, effectiveness and stability. The results obtained with Bioptic demonstrated to us to be a tool important to improve refracting results in safe form | |
dc.description.degreelevel | Especialización | |
dc.description.degreename | Especialista en Oftalmología | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/20510 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Salud | |
dc.publisher.program | Especialización en Oftalmología | |
dc.publisher.school | Escuela de Medicina | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Miopía alta | |
dc.subject | Hipermetropía alta | |
dc.subject | Bioptica | |
dc.subject | ARTISAN® | |
dc.subject | Perdida de células endoteliales cornéales | |
dc.subject | Visante® | |
dc.subject | Worst. | |
dc.subject.keyword | High myopia | |
dc.subject.keyword | High hyperopic | |
dc.subject.keyword | Bioptic | |
dc.subject.keyword | ARTISAN® | |
dc.subject.keyword | Corneal endothelial cells loss | |
dc.subject.keyword | VISANTE® | |
dc.subject.keyword | Worst. | |
dc.title | Implante de lentes faquicos de cámara anterior (artisan°) para pacientes con ametropías altas en el Centro Oftalmológico Virgilio Galvis | |
dc.title.english | Implant of anterior chamber lens (artisan®) for patients with high ametropias in centro oftalmológico virgilio galvis.* | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |