Acrysof restor esférico vs acrysof restor asferico : centramiento y efecto sobre la calidad visual objetiva y subjetiva del paciente

dc.contributor.advisorTello Hernandez, Alejandro
dc.contributor.advisorAparicio, Juan Pablo
dc.contributor.authorFuentes Mendoza, Vanessa Carolina
dc.date.accessioned2024-03-03T17:10:34Z
dc.date.available2008
dc.date.available2024-03-03T17:10:34Z
dc.date.created2008
dc.date.issued2008
dc.description.abstractObjetivos: 1)Comparar la calidad visual objetiva y subjetiva de los pacientes después del implante bilateral de AcrySof ReSTOR esférico vs AcrySof ReSTOR asférico. 2) Medir la calidad visual objetiva y subjetiva de los lentes AcrySof ReSTOR de acuerdo al centramiento en el área pupilar. Diseño: Estudio prospectivo, descriptivo Participantes: 35 pacientes con implante bilateral de ReSTOR esférico y 15 con ReSTOR asférico, evaluados entre enero 2007 y marzo 2008. Metodología: cada paciente recibió una evaluación detallada oftalmológica, descartando patologías oculares diferentes a cataratas. Los pacientes con implante bilateral de AcrySof ReSTOR esférico y asférico tenían agudeza visual para lejos y cerca igual o mejor a 20/30. A todos se les realizó sensibilidad de contraste, análisis de frente de onda, fotografía del área pupilar y encuesta subjetiva de satisfacción visual. Resultados: se evaluaron 100 ojos de 50 pacientes. Se obtuvo diferencia significativa al comparar el Root Mean Square (RMS) de alto orden entre ReSTOR esférico y ReSTOR asférico con valores de 0.25 ± 0.11µm y 0.11 ± 0.09µm respectivamente; y en aberración esférica Z40 con valores de 0.14 ± 0.07µm y 0.03 ± 0.04µm (p<0.05) respectivamente. La aberración de tercer orden tipo coma Z3-1 presento diferencia significativa al comparar los descentramientos del lente ReSTOR con valores de 0.13 ±0.12µm en el cuadrante superonasal, 0.15± 0.04 en el cuadrante inferonasal, 0.36±0.14 en el cuadrante superotemporal y 0.28±0.16 en el cuadrante inferotemporal (p<0.05). Conclusión: El lente AcrySof ReSTOR asférico induce menos aberración esférica y mejor sensibilidad de contraste que el AcrySof ReSTOR esférico. Los descentramientos temporales generan más aberraciones de tercer orden y deterioro de la sensibilidad de contraste, en comparación con los descentramientos nasales.
dc.description.abstractenglishObjective: 1) compare the objective and subjective visual quality of the patients after bilateral implantation of spheric AcrySof ReSTOR vs aspheric AcrySof ReSTOR. 2) Measure the objective and subjective visual quality of the AcrySof ReSTOR according to the pupilar centration. Design: Prospective and descriptive study Participants: 35 patients with bilateral implantation of spheric ReSTOR and 15 patients with aspheric ReSTOR, evaluated between January 2007 and March 2008. Methodology: each patient received a detailed ophthalmological evaluation, sticking ocular pathologies different than cataract. Patients with bilateral implantation of spheric and aspheric AcrySof ReSTOR had visual acuity equal or better than 20/30 for distance and near vision. All patients were performed contrast sensivity, analysis of wavefront, pupilar area photography and subjective visual satisfaction survey. Results: 100 eyes from 50 patients were evaluated. Differences were statistic significant when compare high order root mean square (RMS) between spheric and aspheric ReSTOR with 0.25 ± 0.11µm and 0.11 ± 0.09µm (p<0.05) respectively; and spheric aberrations Z40 with 0.14 ± 0.07µm and 0.03 ± 0.04µm (p<0.05) respectively. The third order aberration coma Z3-1 presented significant difference when comparing ReSTOR decentrations with 0.13 ±0.12µm in superior nasal quadrant, 0.15± 0.04 in inferior nasal quadrant, 0.36±0.14 in superior temporary quadrant and 0.28±0.16 in inferior temporary quadrant (p<0.05). CONCLUSION: The aspheric AcrySof ReSTOR lens induce less spheric aberration and better contrast sensivity than spheric AcrySof ReSTOR. Temporary decentrations generate more third order aberrations and worse contrast sensivity compared with the nasal descentrations.
dc.description.degreelevelEspecialización
dc.description.degreenameEspecialista en Oftalmología
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/21670
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Salud
dc.publisher.programEspecialización en Oftalmología
dc.publisher.schoolEscuela de Medicina
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectReSTOR asférico
dc.subjectCentramiento
dc.subjectSensibilidad de contraste
dc.subjectAberraciones ópticas
dc.subjectCalidad visual
dc.subject.keywordAspheric ReSTOR
dc.subject.keywordCentration
dc.subject.keywordContrast sensivity
dc.subject.keywordOptic aberrations
dc.subject.keywordVisual quality
dc.titleAcrysof restor esférico vs acrysof restor asferico : centramiento y efecto sobre la calidad visual objetiva y subjetiva del paciente
dc.title.englishSpheric acrysof restor vs aspheric acrysof restor: centration and objective œ subjective visual quality efect in the patient
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Documento.pdf
Size:
1.1 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
431.93 KB
Format:
Adobe Portable Document Format