dc.description.abstract | La Unidad de Alquilación (U-4560) del Departamento de Cracking II de la GRB, diseñada para producir 7150 BPD de alquilato a partir de una carga combinada de olefinas e isobutanos balanceados, que reaccionan con ácido sulfúrico presenta un alto consumo energético evidenciado en el aumento del índice de intensidad energética de la planta y por lo tanto del Departamento de Cracking II, lo que genera la incapacidad de aprovechar la energía y una pérdida económica para la Empresa. Se encontró que limitaciones operaciones tales como poco control de la temperatura en los rehervidores de las torres en la zona de fraccionamiento, altas relaciones de reflujo, golpe de ariete, escapes de vapor y la operación no adecuada de los sistemas de trampeo son factores que influyen en el alto consumo de vapor y, por lo tanto, en el consumo energético. El presente proyecto tuvo como propósito identificar el paretto, proponer y evaluar estrategias para incrementar la recuperación energética de la planta. Se creó un sistema de seguimiento a las temperaturas de los rehervidores de las torres de destilación, se encontraron los flujos para mantener una adecuada relación de reflujo en la torre deisoutanizadora, se realizó una identificación, tarjeteo y diagnóstico de las trampas de vapor, se catalogó el pedido de trampas. Finalmente se analizó el consumo de energía eléctrica. | |
dc.description.abstractenglish | The alkylation unit (U-4560) of the Department of Cracking II of the GRB designed to produce 7150 BPD of alkylate from a combined load of olefins and isobutanes balanced that react with sulfuric acid presents a high energy consumption as evidenced by the increase of the rate of energy intensity of the plant and therefore of the Department of Cracking II, generating energy wastage and economic loss for the Company. It was found that limitations operations such as little control of the temperature in the heat exchargers of the towers in the area of fractionation, high relations of reflux, water hammer, steam escapes and the operation is not suitable for trapping systems are factors that influence in the high consumption of steam and therefore in the energy consumption. This project was to identify the purpose paretto, propose and evaluate strategies to increase the energy recovery plant. A system of follow-up to the temperatures of the reboilers of the distillation towers was created, the flows were found to maintain an appropriate relationship of reflux in the debutianizer tower, there was an identification, and diagnosis of steam traps are made, the order of traps was classified. Finally the energy consumption was analyzed. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Químico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/33019 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
dc.publisher.program | Ingeniería Química | |
dc.publisher.school | Escuela de Ingeniería Química | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Recuperación Energética | |
dc.subject | Rehervidor | |
dc.subject | Reflujo | |
dc.subject | Trampa De Vapor. | |
dc.subject.keyword | Energy Recovery | |
dc.subject.keyword | Rehervidor | |
dc.subject.keyword | Reflux | |
dc.subject.keyword | Steam Trap. | |
dc.title | Estrategias para el aprovechamiento energético de la unidad de alquilación u-4560 | |
dc.title.english | Strategies for the energy use of the alkylation unit u-4560 | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 491.13 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 84.81 KB
- Format:
- Adobe Portable Document Format