Desempeño de una edificación de 12 pisos diseñada con sistema estructural de resistencia sísmica (des) de muros de carga en concreto reforzado mediante el método estático no lineal
dc.contributor.advisor | Osorio Bustamante, Edison | |
dc.contributor.author | Uribe Ramírez, Abelardo | |
dc.date.accessioned | 2024-03-04T01:22:28Z | |
dc.date.available | 2021 | |
dc.date.available | 2024-03-04T01:22:28Z | |
dc.date.created | 2021 | |
dc.date.issued | 2021 | |
dc.description.abstract | Inicialmente se realizó el diseño estructural de un edificio de 12 pisos conformado por un sistema estructural de muros de concreto reforzado y losas macizas por medio de un análisis elástico, siguiendo las recomendaciones establecidas en el Reglamento de Construcción Sismo Resistente del 2010, NSR10. En la segunda etapa se evaluó el desempeño sísmico usando el método estático no lineal según ASCE/SEI 4117 y finalmente se hizo retroalimentación del diseño basado en los resultados obtenidos del análisis no lineal, siguiendo las recomendaciones del ACI31819, encontrándose que cumple con los parámetros de seguridad establecidos tanto en el ASCE 4117 como en la NSR10. La evaluación realizada mediante el análisis estático no lineal, la estructura cumple con el objetivo de desempeño establecido, porque los desplazamientos obtenidos del análisis modal espectral son menores a los obtenidos por el método estático no lineal, por tanto, la estructura tiene más capacidad al desplazamiento que la estimada inicialmente. El desplazamiento objetivo que se encuentra graficado con los demás límites de desempeño se encuentra anterior al límite de ocupación inmediata (OI), denominado (S3) según el ASCE 4117 lo cual significa que la estructura para el sismo de diseño se mantiene con las mismas condiciones de capacidad y resistencia. No se presenta pérdidas de vidas humanas y la estructura funciona con normalidad. Se evidenció un aumento significativo de la demanda a cortante en algunos muros del sistema estructural según el análisis estático no lineal, de acuerdo a lo requerido por el ACI31819 se reforzó los muros. | |
dc.description.abstractenglish | Initially, the structural design of a 12 story building was carried out, consisting of a structural system of reinforced concrete walls and solid slabs by means of an elastic analysis, following the recommendations established in the 2010 Earthquake Resistant Construction Regulations, NSR10. In the second stage, the seismic performance was evaluated using the nonlinear static method according to ASCE / SEI 4117 and finally, feedback of the design was made based on the results obtained from the nonlinear analysis, following the recommendations of ACI31819, finding that complies with the security parameters established in both ASCE 4117 and NSR10. The evaluation carried out through the nonlinear static analysis, the structure meets the established performance objective, because the displacements obtained from the spectral modal analysis are lower than those obtained by the nonlinear static method, therefore, the structure has more capacity to displacement than initially estimated. The target displacement that is graphed with the other performance limits is prior to the immediate occupancy limit (OI), called (S3) according to ASCE 4117, which means that the structure for the design earthquake is maintained with the same capacity and resistance conditions. There is no loss of human life and the structure works normally. A significant increase in shear demand was evidenced in some walls of the structural system according to the nonlinear static analysis, as required by ACI31819 the walls were reinforced | |
dc.description.degreelevel | Maestría | |
dc.description.degreename | Magíster en Ingeniería Estructural | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/41981 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Maestría en Ingeniería Estructural | |
dc.publisher.school | Escuela de Ingeniería Civil | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Muros estructurales | |
dc.subject | Muros de cortante | |
dc.subject | Muros delgados | |
dc.subject.keyword | Structural walls | |
dc.subject.keyword | Shear walls | |
dc.subject.keyword | Thin walls | |
dc.title | Desempeño de una edificación de 12 pisos diseñada con sistema estructural de resistencia sísmica (des) de muros de carga en concreto reforzado mediante el método estático no lineal | |
dc.title.english | Performance of a 12story building designed with a structural system of seismic resistance (DES) of loadbearing walls in reinforced concrete using the nonlinear static method. | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_bdcc | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Maestria |
Files