Resultados visuales en la corrección de miopía por laser in situ queratomeleusis y abalación de superficie con la plataforma schwind amaris de 750 hz
dc.contributor.advisor | Tello Hernandez, Alejandro | |
dc.contributor.author | Quintero Mutis, Maria Paula | |
dc.date.accessioned | 2024-03-03T23:37:26Z | |
dc.date.available | 2017 | |
dc.date.available | 2024-03-03T23:37:26Z | |
dc.date.created | 2017 | |
dc.date.issued | 2017 | |
dc.description.abstract | Objetivo: Establecer la seguridad, eficacia, predictibilidad y estabilidad en el tratamiento de la miopía, y el astigmatismo miópico del procedimiento de queratomileusis in situ asistida con excimer láser (LASIK) y de ablación de superficie con la plataforma Schwind Amaris de 750 Hz, en pacientes adultos que se operaron en el Centro Oftalmológico Virgilio Galvis Bucaramanga entre 2012 y 2014. Materiales y Métodos: Estudio observacional de cohorte retrospectivo, cuya información fue tomada de la base de datos del Centro Oftalmológico Virgilio Galvis; de los pacientes con diagnóstico de miopía y astigmatismo miópico sometidos a cirugía entre el 27/09/2012 hasta el 16/01/2014 con técnica quirúrgica tipo LASIK, PRK o T-PRK, utilizando perfil de ablación asférico optimizado de 750 Hz. Resultados: el estudio incluyó 490 ojos que tenían al menos 2,5 meses de seguimiento postoperatorio: 361 operados de LASIK, 89 de PRK y 40 de Trans-PRK. La agudeza visual promedio en el postoperatorio fue de 20/22 para los grupos de LASIK y PRK, y 20/24 para el de Trans-PRK. Alcanzaron una agudeza visual de 20/20 sin corrección el 71,5%, 66,29% y el 80% de los ojos operados de LASIK, PRK y Trans-PRK, respectivamente. El 93,6%, 90% y 92,8% de los ojos operados con LASIK, PRK y Trans-PRK respectivamente, tuvieron un equivalente esférico postoperatorio entre +/- 0.5 D del esperado. 0.83%, 2,5% y 0% de ojos perdieron 2 líneas de agudeza visual con corrección en los grupos de LASIK, PRK y Trans-PRK. Conclusión: La corrección de defectos miópicos con LASIK, PRK y Trans-PRK con una plataforma de excimer láser de disparo flotante con sistema de seguimiento de los movimientos oculares, es segura, predecible y eficaz. Los resultados con las tres técnicas en ojos con miopía de 5,00 Dioptrías o menores, son equivalentes. | |
dc.description.abstractenglish | Objective: To establish safety, efficacy, predictability and stability in the treatment of myopia, and the myopic astigmatism of the procedure of in situ keratomileusis assisted with laser excimer (LASIK) and surface ablation with the 750 Hz Schwind Amaris platform, in Adult patients who were operated at the Virgilio Galvis Bucaramanga Ophthalmological Center between 2012 and 2014. Materials and Methods: Retrospective observational cohort study, whose information was taken from the Virgilio Galvis Ophthalmological Center database; Of patients diagnosed with myopia and myopic astigmatism undergoing surgery between 09/27/2012 to 01/16/2014 using LASIK, PRK or T-PRK surgical technique using an optimized 750 Hz aspheric ablation profile. Results: The study included 490 eyes who had at least 2.5 months postoperative follow-up: 361 operated LASIK, 89 PRK and 40 Trans-PRK. The average visual acuity in the postoperative period was 20/22 for the LASIK and PRK groups, and 20/24 for the Trans-PRK group. They achieved a visual acuity of 20/20 without correction, 71.5%, 66.29% and 80% of LASIK, PRK and Trans-PRK operated eyes, respectively. 93.6%, 90% and 92.8% of eyes operated on with LASIK, PRK and Trans-PRK respectively had a postoperative spherical equivalent between +/- 0.5 D of the expected. 0.83%, 2.5% and 0% of eyes lost 2 lines of visual acuity with correction in the LASIK, PRK and Trans-PRK groups. Conclusion: Correction of myopic defects with LASIK, PRK and Trans-PRK with a floating-excimer laser excimer platform with eye tracking system is safe, predictable and effective. The results with the three techniques in eyes with myopia of 5.00 diopters or less, are equivalent. | |
dc.description.degreelevel | Especialización | |
dc.description.degreename | Especialista en Oftalmología | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/37620 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Salud | |
dc.publisher.program | Especialización en Oftalmología | |
dc.publisher.school | Escuela de Medicina | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Lasik | |
dc.subject | Prk | |
dc.subject | Trans-Prk | |
dc.subject | Excimer Láser | |
dc.subject | Miopía | |
dc.subject | Astigmatismo Miópico | |
dc.subject.keyword | Lasik | |
dc.subject.keyword | Prk | |
dc.subject.keyword | Trans-Prk | |
dc.subject.keyword | Excimer Laser | |
dc.subject.keyword | Myopia | |
dc.subject.keyword | Myopic Astigmatism. | |
dc.title | Resultados visuales en la corrección de miopía por laser in situ queratomeleusis y abalación de superficie con la plataforma schwind amaris de 750 hz | |
dc.title.english | Visual results in the correction of laser miopia in situ queratomileusis and surface ablation, with the schwind amaris platform of 750 hz | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 83.95 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 62.58 KB
- Format:
- Adobe Portable Document Format