Evaluación de la resistencia a la corrosión de un acero inoxidable dúplex DIN/EN 1.4517 para uso en desalinizadores de agua de mar.
dc.contributor.advisor | Rincón Ortiz, Mauricio | |
dc.contributor.advisor | Pérez Ceballos, Ana María | |
dc.contributor.author | Torres Delgado, Ángela Viviana | |
dc.contributor.evaluator | Peña Ballesteros, Darío Yesid | |
dc.contributor.evaluator | Coy Echeverría, Ana Emilse | |
dc.date.accessioned | 2022-04-05T21:28:48Z | |
dc.date.available | 2022-04-05T21:28:48Z | |
dc.date.created | 2022-03-30 | |
dc.date.embargoEnd | 2024-03-30 | |
dc.date.issued | 2022-03-30 | |
dc.description.abstract | Los aceros inoxidables austeníticos y dúplex han sido seleccionados como los principales materiales utilizados en medios agresivos por su buena resistencia a la corrosión. Particularmente, los aceros inoxidables dúplex poseen mayor resistencia a la corrosión localizada y mejores propiedades mecánicas. Estas propiedades hacen que sobresalgan para su uso en desalinizadores de agua de mar, donde especies químicas como los iones cloruro afectan la integridad de las diferentes partes de los equipos. Actualmente, algunos de los componentes de las plantas desalinizadoras como bombas y válvulas se fabrican de aceros inoxidables dúplex en estado fundido. Por lo cual, en este proyecto de investigación se evaluó el comportamiento frente a la corrosión de un acero inoxidable dúplex DIN/EN 1.4517 en estado fundido, al ser expuesto en soluciones de NaCl 3,5% p/p y agua de mar sintética, a temperatura ambiente, 50°C y 70°C. Se realizaron pruebas de corrosión localizada por medio de la técnica de Polarización Potenciodinámica Cíclica (CPP), y con ayuda de técnicas no electroquímicas como Microscopia Óptica confocal y Microscopía Electrónica de Barrido (SEM), se examinó la morfología de los pozos de picado. Adicionalmente, en cada una de las condiciones estudiadas se calculó la velocidad de corrosión, teniendo en cuenta parámetros como la densidad de corriente (icorr) y la resistencia de polarización (Rp) determinados mediante extrapolación de Tafel y Espectroscopía de Impedancia Electroquímica (EIS). Los resultados obtenidos indican que, al aumentar la temperatura el material presenta mayor susceptibilidad a la corrosión localizada y generalizada, este comportamiento se exhibió en ambos medios. Los potenciales críticos de la aleación tienden a valores más negativos al aumentar la temperatura. Los valores calculados de velocidad de corrosión se encuentran entre 0,432 µm/año y 321,590 µm/año, siendo el caso más crítico cuando el acero fue expuesto a una solución de NaCl 3,5% p/p a 70°C. | |
dc.description.abstractenglish | Austenitic and duplex stainless steels have been selected as the main materials used in aggressive environments because of their good corrosion resistance. Particularly, duplex stainless steels have higher resistance to localized corrosion and better mechanical properties. These properties make them outstand for use in seawater desalinators, where chemical species such as chloride ions affect the integrity of the different parts of the equipment. Currently, some of the components of desalination plants such as pumps and valves are made of duplex stainless steels and are in as-cast state. Therefore, in this research project, the corrosion behavior of a duplex stainless steel DIN/EN 1.4517 in as-cast state, when exposed to solutions of NaCl 3.5% w/w and synthetic seawater, at room temperature, 50°C and 70°C. Localized corrosion tests were carried out by means of the Cyclic Potentiodynamic Polarization technique (CPP), and with the help of non-electrochemical techniques such as Optical Microscopy and Scanning Electron Microscope (SEM), the morphology of the pitting wells was examined. Additionally, in each of the conditions studied, the corrosion rate was calculated, considering parameters such as current density (icorr) and polarization resistance (Rp) determined by Tafel extrapolation and Electrochemical Impedance Spectroscopy (EIS). The results obtained indicate that, as the temperature increases, the material presents greater susceptibility to localized and generalized corrosion, this behavior was exhibited in both studied environments. The critical potentials of the alloy tend to more negative values with increasing temperature. The calculated values of corrosion rate are between 0.432 µm/year and 321.590 µm/year, being the most critical case when the steel was exposed to NaCl 3.5% w/w at 70°C. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Metalúrgico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/9707 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
dc.publisher.program | Ingeniería Metalúrgica | |
dc.publisher.school | Escuela de Ingeniería Metalúrgica y Ciencia de Materiales | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Agua potable | |
dc.subject | desalinizadores | |
dc.subject | corrosión por picado | |
dc.subject | aceros inoxidables dúplex | |
dc.subject | velocidad de corrosión | |
dc.subject.keyword | Drinking water | |
dc.subject.keyword | desalinators | |
dc.subject.keyword | pitting corrosion | |
dc.subject.keyword | duplex stainless steel | |
dc.subject.keyword | rate corrosion | |
dc.title | Evaluación de la resistencia a la corrosión de un acero inoxidable dúplex DIN/EN 1.4517 para uso en desalinizadores de agua de mar. | |
dc.title.english | Evaluation of the corrosion resistance of a duplex stainless steel DIN / EN 1.4517 for use in seawater desalinators. | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 134.21 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- Carta de confidencialidad.pdf
- Size:
- 131.39 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 198.28 KB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: