Práctica empresarial: validación de un método analítico por espectroscopía de absorción atómica para la determinación de cd, cr, cu y zn en suelos, lodos y sedimentos
dc.contributor.advisor | Gutierrez Gallego, Jose Carlos | |
dc.contributor.advisor | Morales Aparicio, Estefani | |
dc.contributor.author | Martinez Vega, Yenifer Liceth | |
dc.contributor.evaluator | Vargas Fiallo, Luz Yolanda | |
dc.contributor.evaluator | Bautista Ardila, Gerardo | |
dc.date.accessioned | 2023-06-01T14:57:19Z | |
dc.date.available | 2023-06-01T14:57:19Z | |
dc.date.created | 2023-05-31 | |
dc.date.issued | 2023-05-31 | |
dc.description.abstract | Debido a diferentes actividades antropogénicas, hoy en día evidenciamos gran contaminación ambiental y el deterioro de muchos ecosistemas correlacionados directamente con nuestras necesidades humanas. La contaminación causada por metales tóxicos en suelos, lodos y sedimentos poco se ha considerado aún ambiental y jurídicamente. Ignorando así, su relación directa con la degradación y muerte de vegetación, contaminación de ríos y aguas subterráneas y los efectos nocivos en la salud causados por estos. Según la NTC ISO/IEC 17025:2017 es necesario realizar un proceso de validación a cada uno de los métodos analíticos a implementar en un laboratorio, demostrando a través de evidencia objetiva y experimental la competencia y dominio del método por parte del laboratorio, así como la confiabilidad y calidad de los resultados. Para la determinación de Cadmio, Cromo, Cobre y Zinc en suelos, lodos y sedimentos se consideró el método de digestión ácida bajo la norma US-EPA 3050B, y la técnica de espectrofotometría de absorción atómica por llama US-EPA 7000B. Teniendo en cuenta los rangos de linealidad para cada metal y el análisis de diferentes blancos fortificados a rango bajo, se establecieron los límites de cuantificación experimentales. Con el análisis de materiales de referencia certificados de cada matriz, se determinó el sesgo para cada uno de los metales. La precisión se determinó con muestras reales derivadas de una PTAR. La evaluación de t-student corroboró la veracidad del método analítico. También fue posible realizar comparaciones de dos métodos de digestión EPA 3051A y EPA 3050B, de las cuales se pudo concluir que no existen diferencias significativas entre las varianzas de estos dos métodos. Finalmente, se logró bajo evidencia objetiva y fidedigna concluir que el método validado es apto para la determinación de metales Cadmio, Cromo, Cobre y Zinc en las matrices suelos, lodos y sedimentos. | |
dc.description.abstractenglish | Due to different anthropogenic activities, today we show great environmental contamination and the deterioration of many ecosystems directly correlated with our human needs. The contamination caused by toxic metals in soils, muds and sediments has not yet been considered environmental and legally. Thus ignoring its direct relationship with the degradation and death of vegetation, contamination of rivers and groundwater and the harmful effects on health caused by them. According to NTC ISO/IEC 17025:2017, it is necessary to carry out a validation process for each of the analytical methods to be implemented in a laboratory, demonstrating through objective and experimental evidence the competence and mastery of the method by the laboratory, as well as the reliability and quality of the results. For the determination of Cadmium, Chromium, Copper and Zinc in soils, sludge and sediments, the acid digestion method was considered under the US-EPA 3050B standard, and the US-EPA 7000B flame atomic absorption spectrophotometry technique. Taking into account the linearity ranges for each metal and the analysis of different fortified targets at low range, the experimental quantification limits were established. With the analysis of certified reference materials of each matrix, the bias for each of the metals was determined. The precision was determined with real samples derived from a WWTP. The t-student evaluation corroborated the veracity of the analytical method. It was also possible to make comparisons of two digestion methods EPA 3051A and EPA 3050B, from which it could be concluded that there are no significant differences between the variances of these two methods. Finally, it was achieved under objective and reliable evidence to conclude that the validated method is suitable for the determination of metals Cadmium, Chromium, Copper and Zinc in soil, mud and sediment matrices. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Químico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/14515 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ciencias | |
dc.publisher.program | Química | |
dc.publisher.school | Escuela de Química | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | validación | |
dc.subject | metales | |
dc.subject | cuantificación | |
dc.subject | absorción atómica | |
dc.subject | suelos | |
dc.subject | lodos | |
dc.subject | sedimentos | |
dc.subject.keyword | validation | |
dc.subject.keyword | metals | |
dc.subject.keyword | quantification | |
dc.subject.keyword | atomic absorption | |
dc.subject.keyword | soils | |
dc.subject.keyword | sludge | |
dc.subject.keyword | sediments | |
dc.title | Práctica empresarial: validación de un método analítico por espectroscopía de absorción atómica para la determinación de cd, cr, cu y zn en suelos, lodos y sedimentos | |
dc.title.english | Business practice: validation of an analytical method by atomic absorption spectroscopy for the determination of cd, cr, cu and zn in soils, sludge and sediments | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 300.01 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 47.58 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: