dc.description.abstractLos fenoles son contaminantes orgánicos que se encuentran presentes en diversos efluentes industriales, y se caracterizan por su toxicidad y persistencia en el ambiente. Por lo cual, se hace necesaria su determinación para tomar medidas de control e implementar tratamientos adecuados que reduzcan el impacto ambiental. En este trabajo, la técnica de microbalanza de cristal de cuarzo (QCM) fue empleada para medir fenoles (fenol, o-cresol, m-cresol y p-cresol) en solución acuosa, basada en cambios de frecuencia del cristal. Para mejorar la sensibilidad de medición, el electrodo de la QCM fue modificado con un recubrimiento de polimetilmetacrilato (PMMA). Se estudiaron cinco tipos de solventes (cloroformo, etilacetato, diclorometano, acetona y dicloroetano) para disolver el PMMA, de los cuales se seleccionó el dicloroetano por la uniformidad de sus películas. Así mismo, se contemplaron tres métodos de deposición (drop casting, spin coating y spray coating), donde, spin coating permitió obtener superficies uniformes y mayor repetitividad en las mediciones. Finalmente, se efectuaron mediciones en solución acuosa para tres mezclas fenólicas a composiciones diferentes y para cada uno de los fenoles. Se observaron desplazamientos de frecuencia lineales, en un intervalo de 0,0-0,7 ppm, para diferentes concentraciones de una mezcla fenólica con composición promedio en aguas de producción (46% fenol, 18% o-cresol, 18% m-cresol y 18% p-cresol) reportada en estudios previos; también, de 0,0-1,0 ppm para fenol y de 0,0-0,3 ppm para cresoles. Igualmente, se encontró una mayor sensibilidad para el m-cresol (216 Hz/ppm), en relación con los demás fenoles.
dc.description.abstractenglishPhenols are organic pollutants present in several industrial effluents, and these are characterized by their toxicity and persistence in the environment. Therefore, their determination is necessary to take control measures and implement appropriate treatments that reduce the environmental impact. In this work, Quartz Crystal Microbalance (QCM) technique was used to measure phenols (phenol, o-cresol, m-cresol and p-cresol) in aqueous solutions, based on crystal frequency changes. To improve the sensitivity of measurement, the QCM electrode was modified with a polymethyl methacrylate (PMMA) coating. Five types of solvents (chloroform, ethylacetate, dichloromethane, acetone and dichloroethane) were studied to dilute the PMMA, dichloroethane was selected for the uniformity of its films. Also, three application methods (drop casting, spin coating y spray coating) were contemplated, spin coating allowed to get uniform surfaces and greater repeatability in measurements. Finally, measurements were made in aqueous solution for three phenolic mixtures with different compositions and for each of the phenols. Linear frequency shifts were observed, in the range 0,0-0,7 ppm, for different concentrations of a phenolic mixture with average composition in produced water (46% phenol, 18% o-cresol, 18% m-cresol and 18% p-cresol), reported in previous studies; 0,0-1,0 ppm for phenol and 0,0-0,3 ppm for cresols, too. Likewise, a higher sensitivity was found for m-cresol (216 Hz/ppm), in relation to other phenols.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/38953
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectFenoles
dc.subjectPolimetilmetacrilato
dc.subjectMicrobalanza De Cristal De Cuarzo.
dc.subject.keywordPhenols
dc.subject.keywordPolymethylmetacrylate
dc.subject.keywordQuartz Crystal Microbalance.
dc.titleEvaluación de la técnica de microbalanza de cristal de cuarzo para la determinación de fenoles en solución acuosa
dc.title.englishEvaluation of the quartz crystal microbalance technique for determination of phenols in aqueous solution.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
78.47 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
1.56 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
68.76 KB
Format:
Adobe Portable Document Format