Reproducibilidad intra e interobservadores de los resultados de recuento endotelial con microspia especular de no contacto topcon sp-3000 en la Fundación Oftalmológica de Santander clínica Carlos Ardila Lulle (Foscal) Centro Oftalmológico Virgilio Ga
dc.contributor.advisor | Galvis Ramírez, Virgilio | |
dc.contributor.advisor | Tello Hernández, Alejandro | |
dc.contributor.advisor | Rodríguez Villamizar, Laura Andrea | |
dc.contributor.author | Delgado García, Julián Alberto | |
dc.date.accessioned | 2024-03-03T18:47:39Z | |
dc.date.available | 2011 | |
dc.date.available | 2024-03-03T18:47:39Z | |
dc.date.created | 2011 | |
dc.date.issued | 2011 | |
dc.description.abstract | Objetivo:Analizar la reproducibilidad Inter-intra observador de cada uno de los parámetros que da un examen de Recuento Endotelial Celular con el microscopio especular de no contacto Topcon SP-3000P® en la Fundación Oftalmológica de Santander. Materiales y Métodos: El presente estudio de evaluación tecnológica diagnostica fue realizado durante el segundo periodo de 2009 en la FUNDACION OFTALMOLOGICA DE SANTANDER. Se realizaron medidas de: Número de células analizadas, Tamaño celular promedio, Densidad Celular Endotelial, Hexagonalidad celular en el centro corneal y en cuatro regiones paracentrales con el Microscopio Especular TOPCON SP3000, dos tomas realizadas por el mismo examinador y quince minutos después desconociendo los valores obtenidos por el Examinador 1, dos tomas realizadas por un Segundo examinador. Resultados: Tanto Interevaluador como Intraevaluador se encontró un CCI mayor o igual a 0.90 en la toma central y 4 tomas paracentrales para las medidas de Densidad Corneal y Tamaño Promedio Celular y un CCI menor a 0.60 para Hexagonalidad. Los limites de acuerdo de 95% para evaluar el acuerdo Intra-inter evaluador fueron menores para las medidas centrales. Conclusiones: El examen de Recuento Endotelial con el microscopio especular de No contacto TopconSP-3000 es reproducible Intra-Interexaminador para las medidas de Densidad endotelial Celular y Tamaño promedio Celular teniendo mejor acuerdo intra-interevaluador las medidas en el área corneal central para estas variables. La reproducibilidad Intraevaluador e Interexaminador para la variable Hexagonalidad es | |
dc.description.abstractenglish | Objective: To assess the within- and between-examiner reproducibility of corneal endothelial cell density (ECD) measurements with noncontact specular microscope: Topcon SP-3000P® in the Fundación Oftalmológica de Santander Materials and methods: The present study of diagnostic technology evaluation was made during the second period of 2009 in the FUNDACION OFTALMOLOGICA DE SANTANDER Number of endothelial cells, Average cell size (ACS), endothelial cell density (ECD), and hexagonality values were independently calculated by two examiners with the noncontact specular microscope (NCSM) Topcon SP-3000 in the center and at 4 paracentral areas of 41 eyes of 28 healthy patients. For the Inter-examiner reproducibility, fifteen minutes after a second examiner measured central and four paracentral corneal areas twice. Interexaminer and Within-examiner was analyzed using the Bland-Altman 95% limits of agreement, intra-class correlation coefficient (ICC). Results: Inter-Intraexaminer reproducibility was the best for ACS and ECD measurements in the central and paracentral corneal measurements (ICC > 0.90) but weak for hexagonality (ICC < 0.65). The 95% limits of agreement (LoA) and Standard Deviation to assess Intra-interexaminer reproducibility were also minor for central corneal ACS and ECD. Conclusions: The non contact specular microscope Topcon SP-3000 allows between examiner and within examiner reproducible ACS and ECD measurements on normal corneas, accurate is also the best for central corneal areas. For the calculation of morphometric parameter such as Hexagonality, both interexaminer and within examiner reproducibility was weak. | |
dc.description.degreelevel | Especialización | |
dc.description.degreename | Especialista en Oftalmología | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/26049 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Salud | |
dc.publisher.program | Especialización en Oftalmología | |
dc.publisher.school | Escuela de Medicina | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Densidad Celular Endotelial | |
dc.subject | Número de Células Analizadas | |
dc.subject | Tamaño Celular Promedio | |
dc.subject | Hexagonalidad Celular | |
dc.subject | Microscopio especular de No Contacto | |
dc.subject | Limites de Acuerdo (LoA) | |
dc.subject | Coeficiente de correlación intraclase (CCI) | |
dc.subject.keyword | Endothelial cell density (ECD) | |
dc.subject.keyword | Number of endothelial cells | |
dc.subject.keyword | Average cell size (ACS) | |
dc.subject.keyword | Endothelial cell density (ECD) | |
dc.subject.keyword | Hexagonality | |
dc.subject.keyword | Noncontact specular microscope (NCSM) | |
dc.subject.keyword | Limits of agreement (LoA) | |
dc.subject.keyword | Intraclass correlation coefficient (ICC) | |
dc.title | Reproducibilidad intra e interobservadores de los resultados de recuento endotelial con microspia especular de no contacto topcon sp-3000 en la Fundación Oftalmológica de Santander clínica Carlos Ardila Lulle (Foscal) Centro Oftalmológico Virgilio Ga | |
dc.title.english | Reproducibility within-examiner and interexaminer of corneal endothelial cell density (ecd) measurements with noncontact specular microscope: topcon sp-3000p® at the fundación oftalmológica de santander | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |