Diseño conceptual de un sistema de mezclado en línea para la carga directa de crudo a la unidad U-2100 de la Gerencia Refinería Barrancabermeja

dc.contributor.advisorMorales Medina, Giovanni
dc.contributor.advisorPacheco Acosta, Rosangela
dc.contributor.authorOsma Duarte, Miguel Roberto
dc.contributor.authorGonzález Carvallido, Enildo Nery
dc.contributor.evaluatorBarajas Ferreira, Crisostomo
dc.contributor.evaluatorGodoy Ruíz, Carlos Augusto
dc.date.accessioned2022-09-17T17:05:24Z
dc.date.available2022-09-17T17:05:24Z
dc.date.created2022-09-10
dc.date.issued2022-09-10
dc.description.abstractLa Gerencia Refinería de Barrancabermeja, GRB, presenta oportunidades en la disminución de inventarios de crudos en los tanques de alimentación a las unidades de destilación de crudos; el uso de estos inventarios incrementaría el margen de refinación y disminuiría impuestos anuales. Una alternativa para la eliminación de estos inventarios corresponde a la implementación de un esquema de carga directa a estas unidades. Sin embargo, la carga directa implica el diseño de líneas de conducción de crudo y de un mezclador estático en línea, así como la verificación del cumplimiento de la presión de succión mínima para la bomba de carga a las unidades. En este documento se expone un análisis conceptual que envuelve el diseño de la línea de carga directa, el cálculo de las caídas de presión y la simulación en Aspen Hysys de la alternativa de alimentación directa a la unidad de destilación U-2100. Para lo anterior, los datos históricos de carga con tanque de alimentación fueron recolectados y analizados; asimismo, una simulación en Aspen Hysys validó los resultados de los históricos. El diseño de la línea fue realizado según los valores máximos reportados por los históricos y por la aplicación de balances de masa, de energía mecánica y de ecuaciones semiempíricas para el mezclador estático. También, el diseño conceptual envolvió la proposición de dos lazos de control para la estabilidad de la alimentación por carga directa. Según los resultados, el mezclador estático para el sistema tipo KMS de 10” de diámetro nominal, debe tener una longitud de 100”. La alternativa de cargue directo a la U-2100 conlleva a que la presión de succión de la bomba P-2101, se encuentre por encima de los valores reportados en los datos históricos. Igualmente, los lazos de control propuestos conducen a que la simulación reporte estabilidad ante diferentes perturbaciones.
dc.description.abstractenglishThe Barrancabermeja Refinery Management, GRB, presents opportunities in the reduction of crude oil inventories in the feed tanks for the crude oil distillation units; the use of these inventories would increase the refining margin and reduce annual taxes. An alternative for the elimination of these inventories corresponds to the implementation of a direct loading scheme for these units. However, direct loading implies the design of crude oil pipelines and an in-line static mixer, as well as verification of compliance with the minimum suction pressure for the unit loading pump. This document presents a conceptual analysis that involves the design of the direct loading line, the calculation of pressure drops and the simulation in Aspen Hysys of the direct feeding alternative to the U-2100 distillation unit. For the above, the historical data of loading with feed tank were collected and analyzed; likewise, a simulation in Aspen Hysys validated the results of the historical ones. The design of the line was carried out according to the maximum values ​​reported by the historical ones and by the application of balances of mass, mechanical energy and semi-empirical equations for the static mixer. Also, the conceptual design involved the proposal of two control loops for the stability of the direct load feeding. According to the results, the static mixer for the KMS type system with a nominal diameter of 10” must have a length of 100”. The direct loading alternative to the U-2100 leads to the suction pressure of the P-2101 pump being above the values ​​reported in the historical data. Likewise, the proposed control loops lead to the simulation reporting stability in the face of different disturbances.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero de Procesos de Refinación y Petroquímicos
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/11518
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicoquímicas
dc.publisher.programIngeniería de Procesos de Refinación y Petroquímicos
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleDiseño conceptual de un sistema de mezclado en línea para la carga directa de crudo a la unidad U-2100 de la Gerencia Refinería Barrancabermeja
dc.title.englishConceptual design of an online mixing system for the direct loading of crude oil to the U-2100 unit of the Barrancabermeja Refinery Management
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.type
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
656.88 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
718.9 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Documento.pdf
Size:
1.9 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: