Estimación de la resistencia a la compresión de concreto sin refuerzo a partir de medidas de velocidad de pulso ultrasónico (vpu) utilizando métodos directo e indirecto

dc.contributor.advisorCruz Hernández, Ricardo Alfredo
dc.contributor.advisorQuintero Ortiz, Luz Amparo
dc.contributor.authorAfanador Muñoz, Andres Alfonso
dc.contributor.authorSantacoloma Hoyos, Mauricio Andres
dc.date.accessioned2024-03-03T20:01:57Z
dc.date.available2013
dc.date.available2024-03-03T20:01:57Z
dc.date.created2013
dc.date.issued2013
dc.description.abstractLas técnicas tradicionales utilizadas en la evaluación de estructuras de concreto, basadas en ensayos de compresión y flexión, ofrecen información confiable de la resistencia de éstas, sin embargo las debilitan debido a la extracción de núcleos necesaria para su aplicación. Como consecuencia de esto, en la actualidad se desarrollan nuevas técnicas y se optimizan los ensayos no destructivos ya conocidos para hacerlos más confiables y precisos. Dentro de estos ensayos se encuentran los empleados para estimar la resistencia a la compresión del concreto como la técnica VPU, la cual ha sido aplicada en estudios de evaluación de la calidad y homogeneidad del concreto, usando el método directo el cual ha sido efectivo y altamente confiable. La aplicación de este método está limitada a tener acceso por dos caras opuestas, lo cual no siempre es posible, creándose así la necesidad de utilizar el método de manera indirecta (acceso por una sola cara) para estimar su resistencia a la compresión a través de expresiones matemáticas que permitan esta relación. Por lo anterior, en el presente trabajo se encontraron relaciones matemáticas entre la resistencia a la compresión y medidas de VPU por los métodos de transmisión directa e indirecta, dichas medidas fueron realizadas a especímenes de concreto sin refuerzo tipo columna (100cm x 25cm x 25cm) y cilíndricas (20cm x 10cmØ),en las cuáles se demostró una fuerte correlación entre las variables establecidas y una sensibilidad del método de VPU indirecto a captar variaciones en la compactación, producto de la segregación de los componentes del concreto. Estas muestras se ensayaron durante los 7, 14, 21, 28 y 56 días de curado, en condiciones ambientales (25°C) bajo techo. Cabe destacar que las relaciones y conclusiones encontradas durante el desarrolló de este proyecto son aplicables únicamente a un concreto con las especificaciones usadas en la investigación.
dc.description.abstractenglishTraditional techniques used in the evaluation of concrete structures based in compressive and tensile tests provide reliable information of the strength of these, however they debilitate them due to the extraction of nucleus necessary for their deployment. As a consequence of this, new technologies are developed and known non-destructive tests are optimized in order to make them more reliable and accurate. Among these tests are the ones used to estimate the compressive strength of the concrete like the UPV technique, which has been applied in tests to assess the quality and homogeneity of the concrete using the direct method being effective and highly reliable. The application of these method is limited to the fact of having access to two opposite faces, which is not always possible, making it necessary to use the indirect method (access to one face) to estimate its compressive strength through mathematical expressións that allow this relation. Due to above, in the present work are set the mathematical relations between the compressive strength and the UPV measures through the methods of direct and indirect transmissión. These measures were realized to specimens of unreinforced concrete column type (100cm x 25cm x 25cm) and cylindrical (20cm x 10cmØ), in which a high correlation arose between the set variables and also a strong sensitiveness of the indirect UPV method to capture variations in the compaction due to the segregation of the components of the concrete. These samples were tested during the 7, 14, 21, 28 and 56 days of curing, under indoor environmental conditions (25°C). It is necessary to emphasize that the relations and conclusións found during the development of this project are applicable only to a concrete with the specifications used this research.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Metalúrgico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/28519
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Metalúrgica
dc.publisher.schoolEscuela de Ingeniería Metalúrgica y Ciencia de Materiales
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectVelocidad De Pulso Ultrasónico (Vpu)
dc.subjectSegregación
dc.subjectVpu Por Transmisión Indirecta
dc.subjectResistencia A La Compresión.
dc.subject.keywordUltrasonic Pulse Velocity (Upv)
dc.subject.keywordSegregation
dc.subject.keywordUpv By Indirect Transmissión
dc.subject.keywordCompressive Strength.
dc.titleEstimación de la resistencia a la compresión de concreto sin refuerzo a partir de medidas de velocidad de pulso ultrasónico (vpu) utilizando métodos directo e indirecto
dc.title.englishAssessing the compressive strength of unreinforced concrete though ultrasonic pulse velocity measures using direct and indirect methods.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
240.6 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
2.32 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
250.96 KB
Format:
Adobe Portable Document Format