Desarrollo de un detector de anomalías celulares asociadas al cáncer

dc.contributor.advisorMiranda Mercado, David Alejandro
dc.contributor.advisorOspina Ospina, Rogelio
dc.contributor.advisorGarcía-Martín, José Miguel
dc.contributor.authorBertel Garay, Linda Esperanza
dc.contributor.evaluatorCastillo León, Jaime Alberto
dc.contributor.evaluatorBueno, Paulo Roberto
dc.contributor.evaluatorCastillo León, John Jairo
dc.contributor.evaluatorGarcía Castro, Andrés Camilo
dc.contributor.evaluatorPáez González, Carlos José
dc.date.accessioned2023-03-16T13:35:17Z
dc.date.available2023-03-16T13:35:17Z
dc.date.created2023-03-13
dc.date.embargoEnd2024-03-15
dc.date.issued2023-03-13
dc.description.abstractLa sobre-expresión de receptores de folato en la superficie celular está relacionada con una anomalía asociada al cáncer epitelial. En este sentido, se desarrolló un detector capacitivo que utiliza el ácido fólico como elemento de bio-reconocimiento para la detección de receptores de folato. El detector consiste principalmente en una película delgada de TiO2-WO3 conjugada al ácido fólico, que funciona como electrodo de trabajo en una configuración de celda electroquímica de tres electrodos, junto con un electrodo de referencia de Ag/AgCl [3M] y un contraelectrodo de oro. Las interacciones entre el detector y el receptor de folato fueron estudiadas por medio de la determinación de la capacitancia electroquímica. La película delgada de TiO2-WO3 se fabricó mediante el método de deposición por láser pulsado y posteriormente, se funcionalizó con ácido fólico. La caracterización de la película antes y después de la funcionalización se realizó por medio de AFM, XPS, Raman y ángulo de contacto. Los ensayos de reconocimiento de receptores de folato usando el detector fabricado mostraron que la señal de respuesta del detector, la dureza química (en términos de la capacitancia electroquímica), es selectiva y directamente proporcional a la concentración de receptores de folato, con un límite de detección de 0.2 nM. Este resultado es prometedor en la aplicación de este tipo de detector para el reconocimiento de receptores de folato, especialmente para análisis en el sitio de cuidado.
dc.description.abstractenglishThe overexpression of folate receptors on the cell surface is related to an abnormality associated with epithelial cancer. In this sense, a capacitive detector was developed that uses folic acid as a recognition molecule for the detection of folate receptors. The detector consists mainly of a TiO2-WO3 thin film conjugated to folic acid, which functions as a working electrode in a three-electrode electrochemical cell configuration, together with an Ag/AgCl [3M] reference electrode and a gold counter electrode. The interactions between the detector and the folate receptor were studied by means of the determination of the electrochemical capacitance. TiO2-WO3 thin film was fabricated by the pulsed laser deposition method and subsequently functionalized with folic acid. The characterization of the film before and after functionalization was performed by means of AFM, XPS, Raman, and contact angle. Folate receptor recognition assays using the fabricated detector showed that the detector response signal, chemical hardness (in terms of electrochemical capacitance), is selective and directly proportional to the concentration of folate receptor, with a detection limit of 0.2 nM. This result is promising in the application of this type of detector for the recognition of folate receptors, especially for analysis at the point of care.
dc.description.degreelevelDoctorado
dc.description.degreenameDoctor en Física
dc.description.orcidhttps://orcid.org/0000-0001-8889-2784
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/12594
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ciencias
dc.publisher.programDoctorado en Física
dc.publisher.schoolEscuela de Física
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectBiosensor
dc.subjectPelícula delgada
dc.subjectReceptores de folato
dc.subjectÁcido fólico
dc.subjectCapacitancia
dc.subject.keywordBiosensor
dc.subject.keywordThin Film
dc.subject.keywordFolate Receptors
dc.subject.keywordFolic Acid
dc.subject.keywordCapacitance
dc.titleDesarrollo de un detector de anomalías celulares asociadas al cáncer
dc.title.englishDevelopment of a Detector of Cell Anomalies Associated with Cancer
dc.type.coarhttp://purl.org/coar/resource_type/c_db06
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Doctorado
dspace.entity.type
Files
Original bundle
Now showing 1 - 4 of 4
No Thumbnail Available
Name:
Documento.pdf
Size:
30.83 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
138.63 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
558.86 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de confidencialidad.pdf
Size:
185.7 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: