Caracterización dinámica de puentes en concreto de grandes luces de sección viga cajón construidos por voladizos sucesivos
dc.contributor.advisor | Vivivescas Jaimes, Álvaro | |
dc.contributor.advisor | Riveros Jerez, Carlos Alberto | |
dc.contributor.author | Hernández Sierra, Wilson Alexander | |
dc.date.accessioned | 2024-03-04T01:26:14Z | |
dc.date.available | 2021 | |
dc.date.available | 2024-03-04T01:26:14Z | |
dc.date.created | 2021 | |
dc.date.issued | 2021 | |
dc.description.abstract | El monitoreo de salud estructural basado en vibraciones (SHM) es una herramientaútil para evaluar, verificar y estudiar el estado estructural de los puentes. Generalmente, las pruebasde vibración ambiental (AVT) o las pruebas de vibración forzada (FVT) se utilizan comúnmentepara caracterizar la respuesta dinámica de los puentes, donde la selección de la prueba está enfunción del tipo de puente seleccionado y los recursos económicos disponibles, tanto AVT comoFVT tienen ventajas y limitaciones que se han investigado en puentes con diferentesconfiguraciones estructurales. La ubicación, el número de sensores (acelerómetros) y el tiempo derecopilación de datos juegan un papel importante en la caracterización dinámica de los puentes. Anivel nacional, la construcción de puentes segmentales de concreto con vanos que van desde 50m200m, o incluso con vanos mayores, se está convirtiendo recientemente en la tipología de puentespredominante. Por lo tanto, esta tipología está atrayendo más atención y, por lo tanto, el estudiode las ventajas y limitaciones de la caracterización dinámica de puentes utilizando AVT y /o FVTes vital en el contexto de una definición de un conjunto de ubicaciones óptimas para maximizarlos recursos disponibles (número de acelerómetros y tiempo de recolección de datos entre otros).En esta investigación, AVT y FTV basados en fuentes de excitación seleccionadas de la revisiónde la literatura y las simulaciones numéricas se llevan a cabo utilizando varias configuraciones desensores. La metodología propuesta basada en la colocación óptima del sensor (OSP) muestra quelos AVT que utilizan configuraciones de OSP proporcionan resultados similares a los obtenidoscon los FVT sin considerar las configuraciones de OSP. Además, la relación de costo económicode FVT / AVT se reduce a 2 se logra un tiempo de recopilación de datos más corto con mejorasen los resultados. | |
dc.description.abstractenglish | Vibration-based structural health monitoring (SHM) is a useful tool for evaluating,verifying and studying structural condition of bridges. Generally, ambient vibration tests (AVT)or forced vibration tests (FVT) are commonly used to characterize the dynamic response ofbridges, where the selection of the test is a function of the type of the selected bridge and availableeconomic resources. Both AVT and FVT have advantages and limitations which have beeninvestigated in bridges with different structural configurations. The location and number of sensors(accelerometers) and the data collection time play an important role in the dynamiccharacterization of bridges. At the national level, the construction of segmental concrete bridgeswith spans ranging from 50 m to 200 m, or even with larger spans is recently becoming thepredominant bridge typology. Therefore, this typology is attracting more attention and thus thestudy of the advantages and limitations of bridge dynamic characterization using AVT and/or FVTis vital in the context of a definition of a set of optimal locations to maximize available resources(number of accelerometers and data collection time among others). In this research AVTs andFTVs based on excitation sources selected from the literature review and numerical simulationsare conducted using various sensor configurations (dense array of sensors using longer datacollection time and refined array of sensors optimally located using shorter data collection time).The proposed methodology based on optimal sensor placement (OSP) shows that AVTs using OSPconfigurations provide similar results to those obtained from FVTs without considering OSPconfigurations. Additionally, the FVT / AVT cost ratio is reduced to 2 since a shorter datacollection time is achieved leading to improvements in AVT identification results, especially invertical modes | |
dc.description.degreelevel | Maestría | |
dc.description.degreename | Magíster en Ingeniería Civil | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/42133 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
dc.publisher.program | Maestría en Ingeniería Civil | |
dc.publisher.school | Escuela de Ingeniería Civil | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Identificación modal | |
dc.subject | Pruebas de vibración forzada | |
dc.subject | Vehículos | |
dc.subject | Óptima ubicación de sensores | |
dc.subject | Simulaciones numéricas | |
dc.subject.keyword | Modal identification | |
dc.subject.keyword | Forced vibration test | |
dc.subject.keyword | Optimal sensor placement | |
dc.subject.keyword | Vehicles | |
dc.subject.keyword | numerical simulations | |
dc.title | Caracterización dinámica de puentes en concreto de grandes luces de sección viga cajón construidos por voladizos sucesivos | |
dc.title.english | Dynamic characterization of box girder bridges in concrete with large span built bysuccessive cantilevers * | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_bdcc | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Maestria |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 1.02 MB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 1.62 MB
- Format:
- Adobe Portable Document Format