Estudio del efecto del tratamiento criogénico s obre las propiedades mecánicas de un acero rápido (hss) aisi m7
dc.contributor.advisor | Peña Ballesteros, Darío Yesid | |
dc.contributor.author | Caserta Cárdenas, Diana Yasmin | |
dc.date.accessioned | 2024-03-03T19:36:34Z | |
dc.date.available | 2012 | |
dc.date.available | 2024-03-03T19:36:34Z | |
dc.date.created | 2012 | |
dc.date.issued | 2012 | |
dc.description.abstract | El presente trabajo de investigación presenta el estudio realizado a brocas de centrado fabricadas con acero rápido (HSS high speed steels) AISI M7 usadas en la empresa Transmisiones Homocinéticas de Colombia, después de aplicarles distintos tratamientos criogénicos en los cuales se modificaron las variables tiempo y temperatura de criogenización. Se trabajó con nitrógeno líquido a temperaturas de -100, -143 y -185°C y tiempos de exposición a estas temperaturas de 10,17 y 24 horas respectivamente, esto como resultado de un diseño de experimentos. Se realizaron pruebas tribológicas, mecánicas y metalográficas para verificar los resultados de los tratamientos. Como resultado se observó que la vida útil de las brocas aumentó al comparar piezas sin tratamiento criogénico versus brocas con todos los tratamientos criogénicos planteados, esto originado por el aumento de dureza, la menor pérdida en masa de las brocas después de la realización del ensayo de pin on disk, la conformación de una matriz con carburos distribuidos uniforme y homogéneamente lo cual conlleva a una estructura molecular densa y por ende a una mayor resistencia al desgaste. Todos los ciclos criogénicos mejoraron la vida útil de las brocas, aspecto muy importante para las industrias que buscan mayor competitividad. Sin embargo no se encontró un ciclo en particular que presentará un mejor comportamiento frente a los otros, esto se pudo corroborar mediante el uso del programa estadístico statgraphics centurion donde se observó que la influencia de las variables tiempo y temperatura varía de acuerdo a la característica o propiedad que se evalúe. | |
dc.description.abstractenglish | The present research studies the behavior of the centering drills, after of the application of different cryogenic treatments. Time and temperature of cryogenization were modified. The centering drills were fabricated of AISI M7 steel (HSS high speed steel) and are used in the company TRANSEJES, Transmisiones homocineticas de Colombia. Liquid Nitrogen was used to reduce the temperatures to -100,-143 y -185°C. The exposures times at these temperatures were 10, 17 and 24 hours respectively; according to the experimental design Metallographic, tribological and mechanical tests were used to evaluate the treatments. After the cryogenic treatments the duration of the centering drills increased comparing with the centering drills without cryogenic treatments, all this as a result of the hardness increase, lower lost mass after pin on disk test, and the conformation of a matrix with carbides uniformly and homogeneously distributed, which means a dense molecular structure more resistant to wear. All the cryogenic treatments improve the duration of the centering drills, which is very important for any industry that is looking for increase productivity in their process. However, It was not found a special cycle that present a better behavior compared with the others. This was corroborated using Statgraphics centurion program, where it was observed that the influence of time and temperature of cryogenization change according to the characteristic evaluated. Master | |
dc.description.degreelevel | Maestría | |
dc.description.degreename | Magíster en Ingeniería de Materiales | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/27521 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
dc.publisher.program | Maestría en Ingeniería de Materiales | |
dc.publisher.school | Escuela de Ingeniería Metalúrgica y Ciencia de Materiales | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Tratamientos criogénicos | |
dc.subject | Acero rápido | |
dc.subject | Brocas de centrado. | |
dc.subject.keyword | Cryogenic treatments | |
dc.subject.keyword | High speed steel | |
dc.subject.keyword | Centering drills. | |
dc.title | Estudio del efecto del tratamiento criogénico s obre las propiedades mecánicas de un acero rápido (hss) aisi m7 | |
dc.title.english | Research of the effect of the cryogenic treatment on the mechanical properties of the high speed steel (hss) aisi m7 | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_bdcc | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Maestria |