Respuesta de celulas hos sobre superficies nanoestructuradas de tio2 crecidas mediante anodizacion electroquimica con diferentes electrolitos

dc.contributor.advisorPeña Ballesteros, Darío Yesid
dc.contributor.advisorSandoval Amador, Anderson Andres
dc.contributor.authorFerreira Ospina, Jessica Julieth
dc.contributor.authorMoreno Segovia, Juan Camilo
dc.date.accessioned2023-04-06T14:46:42Z
dc.date.available2023
dc.date.available2023-04-06T14:46:42Z
dc.date.created2019
dc.date.issued2019
dc.description.abstractLa fabricación de implantes ortopédicos usando superficies biofuncionalizadas, como el titanio grado 5, facilitan la interfaz material-célula permitiendo tener un mayor grado de adherencia y proliferación celular, generando así, una mejor calidad de vida en los pacientes. Para que la adhesión celular ocurra, se debe tener en cuenta, principalmente, las características químicas y superficiales del material base. En este trabajo se evaluó la interacción entre las células de osteosarcoma humano (HOS) y superficies biofuncionalizadas mediante anodización electroquímica de aleación de Ti6Al4V. Las superficies fueron anodizadas con 3 electrolitos diferentes (ácidos, sales de fluoruro y orgánicos), además se utilizó una superficie de control sin recubrimiento. Para el análisis morfológico de los nanotubos de TiO2, se observó en el microscopio electrónico de barrido. La respuesta biológica del material se llevó a cabo usando células HOS en medio RPMI-1640, con suero fetal bovino al 10%v y 1%v de antibióticos. Además, se realizaron pruebas cuantitativas de adherencia celular, citotoxicidad y cualitativas de epifluorescencia. Sin embargo, los resultados muestran que las superficies recubiertas no superan en adherencia la superficie de control, por lo que finalmente, se hizo una reconstrucción 3D de las superficies analizadas con el fin de determinar el perfil de rugosidad de las muestras, ya que la rugosidad de la superficie es un factor determinante que favorece la adhesión. Se determinó que a las condiciones de anodización realizadas (20V y 1 hora) no se generan superficies con un grado de rugosidad óptimo que favorezca la adhesión de las células a la superficie de aleación, y que la superficie anodizada con el electrolito orgánico genera una citotoxicidad no apta para ser implantada en el cuerpo humano, ya que esta presenta un alto porcentaje de inhibición celular. ___________________
dc.description.abstractenglishThe manufacture of orthopedic implants using biofunctionalized surfaces, such as grade 5 titanium, facilitates the material-cell interface allowing a greater degree of adhesion and cell proliferation, thus generating a better quality of life in patients. For the cell adhesion to occur, the chemical and surface characteristics of the base material must be taken into account. In this work, the interaction between human osteosarcoma cells (HOS) and biofunctionalized surfaces was evaluated by electrochemical anodization of Ti6Al4V alloy. The surfaces were anodized with 3 different electrolytes (acids, fluoride salts and organic), besides, an uncoated control surface was used. For the morphological analysis of the TiO2 nanotubes, it was observed in the scanning electron microscope. The biological response of the material was carried out using HOS cells in RPMI-1640 medium, with 10% v fetal bovine serum and 1% v antibiotics. Also, quantitative tests of cell adhesion, cytotoxicity, and qualitative epifluorescence were made. However, the results show that the coated surfaces do not exceed in adhesion the control surface, consequently, a 3D reconstruction of the analyzed surfaces was made in order to determine the roughness profile of the samples, since the roughness of the surface is a determining factor that favors adhesion. It was determined that at the anodizing conditions performed (20V and 1 hour) do not generate surfaces with an optimum degree of roughness that favors the cells adhesion to the alloy surface and that the anodized surface with the organic electrolyte generates an unsuitable cytotoxicity to be implanted in the human body, because this presents a high percentage of cellular inhibition. _______________________
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/13782
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCitotoxicidad
dc.subjectRugosidad
dc.subjectElectrolito
dc.subjectAdherencia Celular.
dc.subject.keywordCytotoxicity
dc.subject.keywordRoughness
dc.subject.keywordElectrolyte
dc.subject.keywordCell Adhesion. Authors: Jessica Julieth Ferreira Ospina. Juan Camilo Moreno Segovia **
dc.titleRespuesta de celulas hos sobre superficies nanoestructuradas de tio2 crecidas mediante anodizacion electroquimica con diferentes electrolitos
dc.title.englishHos cells response on nano-structured surfaces of tio2 growth through electrochemical anodization with different electrolytes.* keywords: cytotoxicity, roughness, electrolyte, cell adhesion.
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
dspace.entity.type
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
267.7 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
1.73 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
252.17 KB
Format:
Adobe Portable Document Format