EVALUACIÓN DE LA OPERACIÓN DE LA UNIDAD VISCORREDUCTORA II CON UN SÓLO HORNO EN LA REFINERÍA DE BARRANCABERMEJA DE ECOPETROL S.A.
dc.contributor.advisor | Sandoval Correa, Andrea Paola | |
dc.contributor.advisor | Duarte León, Diana Marcela | |
dc.contributor.author | Higuera Mejía, Joan Fernando | |
dc.contributor.evaluator | Martinez Rey, Ramiro | |
dc.contributor.evaluator | Avellaneda Vargas, Fredy Augusto | |
dc.date.accessioned | 2024-08-27T12:17:03Z | |
dc.date.available | 2024-08-27T12:17:03Z | |
dc.date.created | 2024-08-23 | |
dc.date.issued | 2024-08-23 | |
dc.description.abstract | El propósito de esta investigación fue evaluar la viabilidad de operar la Unidad Viscorreductora II de la GRB con un solo horno. Originalmente, esta unidad fue diseñada para procesar 24 mil barriles por día (KBPD) de fondos provenientes de la Unidad Demex, utilizando dos hornos que operan en paralelo. Cada horno requiere una carga mínima de 10 KBPD y máxima de 12 KBPD debido a condiciones de diseño. Actualmente, la carga promedio de la unidad se ha reducido a 12 KBPD de fondos Demex. Para garantizar la carga mínima a los hornos se mantiene una recirculación promedio de 10 KBPD, la cual es parte de su producto final (BREA). Aunque la carga de la unidad se ha reducido a la mitad, no se ha observado una disminución proporcional en el consumo de gas combustible. Los hornos consumen 125,78 MBTU/h a máxima carga, y su operación actual con casi una reducción del 50% de su carga, presenta un consumo de gas combustible de 112,16 MBTU/h. Para reducir este consumo, se proponen dos alternativas. La opción más viable contempla dejar un horno en modo de preservación, inicialmente utilizando gas combustible. Esta estrategia busca reducir el consumo de gas combustible y las emisiones de gases de efecto invernadero (GEI), además de proporcionar flexibilidad operativa a la planta. Permitirá variar la carga desde 10 KBPD hasta 24 KBPD al encender el horno en preservación, en caso de ser necesario debido a altos inventarios en la GRB. Esta alternativa también tiene el beneficio de mejorar la continuidad operativa de la unidad, ya que, al realizar mantenimiento al horno que está en operación, el horno preservado puede ser puesto en funcionamiento. Se espera una reducción en el consumo de gas combustible de entre 5,12 MBTU/h y 16,96 MBTU/h, lo que equivale a una disminución de 2.706 TonCO2e/año a 8.957 TonCO2e/año. El ahorro económico estimado oscila entre USD 269.000,00 y USD 890.000,00, considerando un precio de USD 6,00 por MBTU de gas combustible. Es importante destacar que este proyecto es viable y estos beneficios se lograrán siempre que se pueda producir vapor mediante alguna alternativa presentada en el Estudio de Conceptualización, suplir los requerimientos energéticos de la torre T2502 de la Unidad Demex y encontrar un método de preservación del horno que consuma poco o no consuma gas combustible. | |
dc.description.abstractenglish | The purpose of this research was to evaluate the feasibility of operating the Viscosity Reduction Unit II at the Barrancabermeja Refinery (GRB) with a single furnace. Originally, this unit was designed to process 24 thousand barrels per day (KBPD) of bottoms from the Demex Unit, using two furnaces operating in parallel. Each furnace requires a minimum load of 10 KBPD and a maximum of 12 KBPD due to design conditions. Currently, the average load of the unit has been reduced to 12 KBPD of Demex bottoms. To ensure the minimum load to the furnaces, an average recirculation of 10 KBPD is maintained, which is part of the final product (BREA). Although the unit’s load has been halved, there has not been a proportional reduction in fuel gas consumption. The furnaces consume 125.78 MBTU/h at maximum load, and their current operation, with almost a 50% reduction in load, shows a fuel gas consumption of 112.16 MBTU/h. To reduce this consumption, two alternatives are proposed. The most viable option involves putting one furnace in preservation mode, initially using fuel gas. This strategy aims to reduce fuel gas consumption and greenhouse gas (GHG) emissions, in addition to providing operational flexibility to the plant. It will allow the load to vary from 10 KBPD to 24 KBPD by igniting the preserved furnace if necessary due to high inventories at the GRB. This alternative also has the benefit of improving the unit’s operational continuity since, during maintenance of the operating furnace, the preserved furnace can be brought online. A reduction in fuel gas consumption of between 5.12 MBTU/h and 16.96 MBTU/h is expected, equivalent to a decrease of 2,706 TonCO2e/year to 8,957 TonCO2e/year. The estimated economic savings range from USD 269,000.00 to USD 890,000.00, considering a fuel gas price of USD 6.00 per MBTU. It is important to note that this project is feasible, and these benefits will be achieved as long as steam can be produced through an alternative presented in the Conceptualization Study, the energy requirements of the T-2502 tower of the Demex Unit are met, and a preservation method for the furnace that consumes little or no fuel gas is found. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Químico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/43904 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
dc.publisher.program | Ingeniería Química | |
dc.publisher.school | Escuela de Ingeniería Química | |
dc.rights | info:eu-repo/semantics/embargoedAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Ahorro energético | |
dc.subject | Descarbonización | |
dc.subject | Reducción del consumo de gas combustible | |
dc.subject | Operación con un horno | |
dc.subject | Viscorreducción | |
dc.subject.keyword | Decarbonization | |
dc.subject.keyword | Reduction in fuel gas consumption | |
dc.subject.keyword | Energy savings | |
dc.subject.keyword | Operation with a single furnace | |
dc.subject.keyword | Visbreaking | |
dc.title | EVALUACIÓN DE LA OPERACIÓN DE LA UNIDAD VISCORREDUCTORA II CON UN SÓLO HORNO EN LA REFINERÍA DE BARRANCABERMEJA DE ECOPETROL S.A. | |
dc.title.english | Evaluation of the Operation of the Visbreaker Unit II with Single Furnace at the Barrancabermeja Refinery of ECOPETROL S.A.* | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Carta de confidencialidad.pdf
- Size:
- 18.7 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 165.32 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 92.3 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: