Desempeño de una edificación de 12 pisos diseñada con sistema estructural de resistencia sísmica (DES) de muros de carga en concreto reforzado mediante el método estático no lineal

dc.contributor.advisorOsorio Bustamante, Edison
dc.contributor.authorUribe Ramírez, Abelardo
dc.contributor.evaluatorGaviria Mendoza, Carlos Andrés
dc.contributor.evaluatorZapata Orduz, Luis Eduardo
dc.date.accessioned2022-04-01T04:04:19Z
dc.date.available2022-04-01T04:04:19Z
dc.date.created2021
dc.date.issued2021
dc.description.abstractInicialmente se realizó el diseño estructural de un edificio de 12 pisos conformado por un sistema estructural de muros de concreto reforzado y losas macizas por medio de un análisis elástico, siguiendo las recomendaciones establecidas en el Reglamento de Construcción Sismo Resistente del 2010, NSR-10. En la segunda etapa se evaluó el desempeño sísmico usando el método estático no lineal según ASCE/SEI 41-17 y finalmente se hizo retroalimentación del diseño basado en los resultados obtenidos del análisis no lineal, siguiendo las recomendaciones del ACI-318-19, encontrándose que cumple con los parámetros de seguridad establecidos tanto en el ASCE 41-17 como en la NSR-10. La evaluación realizada mediante el análisis estático no lineal, la estructura cumple con el objetivo de desempeño establecido, porque los desplazamientos obtenidos del análisis modal espectral son menores a los obtenidos por el método estático no lineal, por tanto, la estructura tiene más capacidad al desplazamiento que la estimada inicialmente. El desplazamiento objetivo que se encuentra graficado con los demás límites de desempeño se encuentra anterior al límite de ocupación inmediata (OI), denominado (S-3) según el ASCE 41-17 lo cual significa que la estructura para el sismo de diseño se mantiene con las mismas condiciones de capacidad y resistencia. No se presenta pérdidas de vidas humanas y la estructura funciona con normalidad. Se evidenció un aumento significativo de la demanda a cortante en algunos muros del sistema estructural según el análisis estático no lineal, de acuerdo a lo requerido por el ACI318-19 se reforzó los muros.
dc.description.abstractenglishInitially, the structural design of a 12 story building was carried out, consisting of a structural system of reinforced concrete walls and solid slabs by means of an elastic analysis, following the recommendations established in the 2010 Earthquake Resistant Construction Regulations, NSR-10. In the second stage, the seismic performance was evaluated using the non-linear static method according to ASCE / SEI 41-17 and finally, feedback of the design was made based on the results obtained from the non-linear analysis, following the recommendations of ACI-318-19, finding that complies with the security parameters established in both ASCE 41-17 and NSR-10. The evaluation carried out through the non-linear static analysis, the structure meets the established performance objective, because the displacements obtained from the spectral modal analysis are lower than those obtained by the non-linear static method, therefore, the structure has more capacity to displacement than initially estimated. The target displacement that is graphed with the other performance limits is prior to the immediate occupancy limit (OI), called (S-3) according to ASCE 41-17, which means that the structure for the design earthquake is maintained with the same capacity and resistance conditions. There is no loss of human life and the structure works normally. A significant increase in shear demand was evidenced in some walls of the structural system according to the nonlinear static analysis, as required by ACI318-19 the walls were reinforced.
dc.description.degreelevelMaestría
dc.description.degreenameMagíster en Ingeniería Estructural
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/9489
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicomecánicas
dc.publisher.programMaestría en Ingeniería Estructural
dc.publisher.schoolEscuela de Ingenieria Civil
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectMuros estructurales
dc.subjectMuros de cortante
dc.subjectMuros delgados
dc.subject.keywordStructural Walls
dc.subject.keywordShear Walls
dc.subject.keywordThin Walls
dc.titleDesempeño de una edificación de 12 pisos diseñada con sistema estructural de resistencia sísmica (DES) de muros de carga en concreto reforzado mediante el método estático no lineal
dc.title.englishPerformance of a 12-story building designed with a structural system of seismic resistance (DES) of load-bearing walls in reinforced concrete using the non-linear static method
dc.type.coarhttp://purl.org/coar/resource_type/c_bdcc
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Maestría
dspace.entity.type
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
183291_licence.pdf
Size:
127.66 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
183291_nota.pdf
Size:
195.52 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
183291_trabajo.pdf
Size:
4.04 MB
Format:
Adobe Portable Document Format