Estudio de pre-factibilidad para el incremento del factor de utilización de la unidad recuperadora de Etano-Etileno del departamento de Cracking II en la Refinería de Barrancabermeja
dc.contributor.advisor | Duarte Duarte, Diana Paola | |
dc.contributor.advisor | Rivera, Carlos Alberto | |
dc.contributor.author | Mogollón Arenas, Javier Alonso | |
dc.contributor.author | Rincón Rincón, Jairo Yesid | |
dc.contributor.evaluator | Castro Molano, Liliana del Pilar | |
dc.contributor.evaluator | Morales Medina, Giovanni | |
dc.date.accessioned | 2022-09-16T21:36:19Z | |
dc.date.available | 2022-09-16T21:36:19Z | |
dc.date.created | 2022-09-14 | |
dc.date.issued | 2022-09-14 | |
dc.description.abstract | En el caso del proceso de recuperación de etano etileno, los efectos de la desactivación del catalizador de FCC impactan directamente el funcionamiento del compresor de gas esponja C-4301 debido a que incrementa la relación de Hidrógeno/Metano de éste y por tanto afecta el peso molecular del gas en la succión del C-4301, ocasionando que su operación se encuentre muy frecuentemente al límite de desempeño. La variación en el peso molecular del gas en el lado de la succión ocasiona un aumento en la velocidad angular y genera un aumento en la presión de succión, lo que ocasiona el desvío de gas esponja hacia la red de gas combustible de la refinería a través de la apertura de la válvula de control de presión PV-43005. Con el fin de recuperar parte del gas esponja que se está perdiendo al enviarlo a la red de gas combustible y valorizarlo posteriormente como polietileno, este trabajo tiene como objetivo la evaluación de dos alternativas planteadas para regular el peso molecular a la succión del compresor: inyectar gas natural o recircular etano etileno producto, esto teniendo en cuenta la disponibilidad de dichas corrientes en la unidad. La evaluación de las alternativas se llevó a cabo a través de una simulación del proceso en Aspen Hysys v12 planteando diferentes escenarios de operación. Los resultados obtenidos permitieron identificar que la mejor opción en cuanto a recuperación de etano-etileno de la recirculación de producto considerando las condiciones de diseño de la unidad, variables operativas clave y disponibilidad de recursos. Teniendo la alternativa seleccionada, se evalúan los costos y diferentes retos operacionales a tener en cuenta a la hora de iniciar la implementación. Finalmente, se brindan recomendaciones para futuros análisis relacionados con esta problemática. | |
dc.description.abstractenglish | In the case of the ethylene ethane recovery process, the effects of the FCC catalyst deactivation directly impact the operation of the C-4301 sponge gas compressor because it increases its Hydrogen/Methane ratio and therefore affects the molecular gas weight, in the suction of C-4301. The effects of the FCC catalyst deactivation directly impact the operation of the C-4301 sponge gas compressor because it increases its Hydrogen/Methane ratio and therefore affects the molecular gas weight, in the suction of C-4301. Causing its operation to be very frequently at the limit of performance. The molecular weight variation of the gas on the suction side causes an increase in the angular velocity and an increase in the suction pressure, which causes the deviation of sponge gas towards the refinery fuel gas network through the opening of the pressure control valve PV-43005. In order to recover part of the sponge gas that is being lost by sending it to the fuel gas network and subsequently recovering it as polyethylene, the objective of this work is the evaluation of two proposed alternatives to regulate the molecular weight at the suction of the compressor; by injecting natural gas or recirculating ethane-ethylene product, taking in mind the availability of those flows in the unit. The evaluation of options was carried out through a simulation of the process in Aspen Hysys v12, raising different operating scenarios. The results obtained allowed us to identify the best option in terms of ethane-ethylene recovery from product recirculation considering the design conditions of the unit, key operating variables, and availability of resources. Having the alternative selected, an evaluation of budgets and a range of operational challenges to be taken at the time of starting the implementation. Finally, recommendations are provided for future analyzes related to this issue. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero de Procesos de Refinación y Petroquímicos | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/11495 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
dc.publisher.program | Ingeniería de Procesos de Refinación y Petroquímicos | |
dc.publisher.school | Escuela de Ingeniería Química | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Peso Molecular | |
dc.subject | Etano | |
dc.subject | Etileno | |
dc.subject | Polietileno | |
dc.subject | Gas natural | |
dc.subject | Gas Esponja | |
dc.subject.keyword | molecular weight | |
dc.subject.keyword | ethane | |
dc.subject.keyword | ethylene | |
dc.subject.keyword | polyethylene | |
dc.subject.keyword | natural gas | |
dc.subject.keyword | sponge gas | |
dc.title | Estudio de pre-factibilidad para el incremento del factor de utilización de la unidad recuperadora de Etano-Etileno del departamento de Cracking II en la Refinería de Barrancabermeja | |
dc.title.english | Pre-feasibility study to increase the utilization factor of the Ethane-Ethylene recovery unit of the Cracking II Department at the Barrancabermeja refinery | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 668.16 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de Proyecto.pdf
- Size:
- 604.07 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: