Influencia de las variables de operación sobre el índice de reactividad del clinker en la planta Rioclaro Cementos Argos S.A.

dc.contributor.advisorPedraza Avella, Julio Andrés
dc.contributor.advisorSotelo Lopéz, David Julián
dc.contributor.authorÁvila Guerrero, Juan David
dc.contributor.evaluatorBarajas Ferreira, Crisostomo
dc.contributor.evaluatorLaverde Cataño, Dionicio Antonio
dc.date.accessioned2024-08-21T12:29:17Z
dc.date.available2024-08-21T12:29:17Z
dc.date.created2024-08-20
dc.date.issued2024-08-20
dc.description.abstractEl presente trabajo de grado tuvo como objetivo analizar la influencia de las variables de operación del proceso sobre el índice de reactividad del clinker (IRC) en la Planta de Cementos Argos S.A. Rioclaro. Para ello, se tomaron muestras del clinker, registrando las 13 variables de operación: temperatura de entrada al horno (TE), temperatura aire secundario (TS), temperatura del calcinador (TC), presión aire primario (PAP), presión aire terciario (PAT), presión soplador horno (PSH), presión soplador calcinador (PSC), presión de la cama de enfriador (PCE), temperatura de la salida de gases downcomer (TSD), temperatura de la salida de gases aire de exceso (TSG), alimentación del horno (ALH), velocidad del horno (VH) y oxígeno en cámara (OX). Las muestras se observaron por microscopia óptica y se analizó su morfología microestructural con el fin de determinar el IRC, de acuerdo con el protocolo de la planta. Durante los seis (6) meses de la práctica empresarial se analizaron 37 muestras, obteniéndose valores de IRC entre 0,849 y 0,597. Posteriormente, se realizó un análisis de regresión lineal múltiple con el fin de desarrollar un modelo para correlacionar las variables de operación con el IRC. Para ello se normalizaron los datos recolectados y se eliminaron las variables menos significativas estadísticamente (Valor-P > 0.05) así como los datos atípicos (valores estudentizados > 2). El modelo con mejor ajuste (𝑅^2 = 0,853) se obtuvo considerando 7 variables de operación (TE, PAP, PSH, PSC, PCE, ALH, VH) y eliminado 11 datos atípicos. No obstante, teniendo en cuenta la relevancia fisicoquímica de TC en el proceso de producción de clinker, se decidió incluir esta variable en el modelo. Esto condujo a un mejor ajuste (𝑅^2 = 0,971) pero implico la eliminación de 16 datos atípicos.
dc.description.abstractenglishThe present thesis aims to examine the impact of process operation variables on the clinker reactivity index (IRC) at the Cementos Argos S.A. Rioclaro Plant. To achieve this objective, clinker samples were collected, and data were recorded for 13 operation variables: furnace inlet temperature (TE), secondary air temperature (TS), calciner temperature (TC), primary air pressure (PAP), tertiary air pressure (PAT), furnace blower pressure (PSH), calciner blower pressure (PSC), cooler bed pressure (PCE), downcomer gas outlet temperature (TSD), excess air outlet temperature (TSG), furnace feed rate (ALH), furnace speed (VH), and oxygen content in the chamber (OX). The samples underwent optical microscopy analysis to study their microstructural morphology and determine IRC according to the plant's established protocol. During the six-month industrial practice period, 37 samples were analyzed, revealing IRC values ranging from 0.849 to 0.597. Subsequently, a multiple linear regression analysis was conducted to develop a model correlating the operation variables with IRC. The collected data were normalized, and variables deemed statistically insignificant (P-value > 0.05) and outliers (studentized values > 2) were excluded. The best-fitting model (𝑅2 = 0.853) was achieved using 7 operation variables (TE, PAP, PSH, PSC, PCE, ALH, VH) after removing 11 outliers. Nevertheless, acknowledging the physicochemical significance of TC in the clinker production process, this variable was included in the model, resulting in an enhanced fit (𝑅2 = 0.971) but necessitating the exclusion of 16 outliers.
dc.description.degreelevelPregrado
dc.description.degreenameIngeniero Químico
dc.format.mimetypeapplication/pdf
dc.identifier.instnameFacultad de Ingeníerias Fisicoquímicas
dc.identifier.reponameEscuela de Ingeniería Química
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/43808
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingeníerias Fisicoquímicas
dc.publisher.programIngeniería Química
dc.publisher.schoolEscuela de Ingeniería Química
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_f1cf
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectclinker
dc.subjectíndice de reactividad
dc.subjectvariables de operación
dc.subjectArgos S.A.
dc.subject.keywordclinker
dc.subject.keywordreactivity index
dc.subject.keywordoperating variables
dc.subject.keywordArgos S.A.
dc.titleInfluencia de las variables de operación sobre el índice de reactividad del clinker en la planta Rioclaro Cementos Argos S.A.
dc.title.englishInfluence of operating variables on the reactivity index of clinker at the Rioclaro Cementos Argos S.A. plant.
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1f
dc.type.hasversionhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 4 of 4
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
90.16 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Carta de confidencialidad.pdf
Size:
43.05 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
120.78 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
546.17 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.18 KB
Format:
Item-specific license agreed to upon submission
Description: