Cardiotacómetro digital prototipo para estudio de la variabilidad de la frecuencia cardiaca
dc.creator | Barrero Pérez, Jaime Guillermo | |
dc.creator | Rueda, Oscar León | |
dc.creator | Pinto Aparicio, Miguel | |
dc.creator | Gonzáles Barajas, Javier | |
dc.date | 2003-12-03 | |
dc.date.accessioned | 2022-03-14T20:29:29Z | |
dc.date.available | 2022-03-14T20:29:29Z | |
dc.description | In this article we present the Digital Cardiotachometer, a prototype built to take the cardiac signal of a patient and perform calculations of instantaneous heart rate based on the detection of the R wave of the cardiac complex. These heart rate calculations are very useful when conducting studies on heart rate variability (HRV) in order to assess the conditions in which a patient's autonomic nervous system is located. | en-US |
dc.description | En este articulo se expone el Cardiotacómetro Digital, Ull prototipo construido para tomar laseñal cardiaca de un paciente y realizar cálculos de fi"ecuencia cardiaca instantánea con base enla detección de la onda R del complejo cardiaco. Estos cálculos de fi'ecuencia cardiaca son degran utilidad a la hora de realizar estudios acerca de la variabilidad de la Frecuencia Cardiaca(VF C) con elfin de evaluar las condiciones en que se encuentra el sistema nenJioso autónomo deun paciente. | es-ES |
dc.format | application/pdf | |
dc.identifier | https://revistas.uis.edu.co/index.php/revistauisingenierias/article/view/2282 | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/8180 | |
dc.language | spa | |
dc.publisher | Universidad Industrial de Santander | es-ES |
dc.relation | https://revistas.uis.edu.co/index.php/revistauisingenierias/article/view/2282/2637 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.source | REVISTA UIS ENGENHARIAS; v. 2 n. 2 (2003): Revista UIS Ingenierías; 81-86 | pt-BR |
dc.source | Revista UIS Ingenierías; Vol. 2 Núm. 2 (2003): Revista UIS Ingenierías; 81-86 | es-ES |
dc.source | Revista UIS Ingenierías; Vol. 2 No. 2 (2003): Revista UIS Ingenierías; 81-86 | en-US |
dc.source | 2145-8456 | |
dc.source | 1657-4583 | |
dc.subject | Cardiotachometer, variability, heart rate, r-r times. | en-US |
dc.subject | Cardiotachometer | en-US |
dc.subject | variability | en-US |
dc.subject | heart rate | en-US |
dc.subject | r-r times | en-US |
dc.subject | Cardiotacómetro | es-ES |
dc.subject | variabilidad | es-ES |
dc.subject | frecuencia cardiaca | es-ES |
dc.subject | tiempos r-r | es-ES |
dc.title | Cardiotacómetro digital prototipo para estudio de la variabilidad de la frecuencia cardiaca | es-ES |
dc.title | Cardiotacómetro digital prototipo para estudio de la variabilidad de la frecuencia cardiaca | en-US |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion | |
dspace.entity.type |