Evaluación energética de los intercambiadores de sistema de media presión de la planta de Polietileno II de la Gerencia Refinería Barrancabermeja
dc.contributor.advisor | Ramírez Caballero, Gustavo Emilio | |
dc.contributor.advisor | Herrera Betancourth, Pedro Elías | |
dc.contributor.advisor | Guerrero Mesa, Arley | |
dc.contributor.author | Martínez Lamus, Laura Viviana | |
dc.contributor.evaluator | Viatcheslav, Kafarov | |
dc.contributor.evaluator | Ramírez Caballero, Gustavo Emilio | |
dc.date.accessioned | 2022-11-04T20:12:27Z | |
dc.date.available | 2022-11-04T20:12:27Z | |
dc.date.created | 2022-11-03 | |
dc.date.issued | 2022-11-03 | |
dc.description.abstract | La planta de Polietileno II de la GRB de Ecopetrol produce resinas de Polietileno de baja densidad. Se ha evidenciado un aumento en la temperatura del etileno que ingresa al reactor, disminuyendo el flujo de gas, la producción y la seguridad de la planta. Teniendo en cuenta las fechas de los mantenimientos, se estableció el intervalo de tiempo en el que se realizó el análisis de los preenfriadores. Con los datos de planta registrados, se calculó la eficiencia de estos equipos durante este periodo y se obtuvo una eficiencia promedio aproximadamente 30% menor que la de diseño, debido a que el gas que entra a los intercambiadores contiene polímeros de cadena corta que se solidifican al disminuir su temperatura y crean una capa de ensuciamiento que interfiere en la transferencia de calor. Finalmente, se propusieron tres alternativas de mejora, se simularon en Aspen Hysys v10 y se compararon las temperaturas de salida del E2253A en cada una. Se obtuvo un mejor resultado con la mejora 3, la cual consiste en circular el gas simultáneamente por ambos trenes, pues al disminuir la carga de cada equipo, se incrementa la velocidad del fluido, aumentando el coeficiente global de transferencia de calor. | |
dc.description.abstractenglish | Ecopetrol's GRB Polyethylene II plant produces low-density Polyethylene resins. An increase in the temperature of the gaseous ethylene entering the reactor has been evidenced, decreasing gas flow, production and increasing the risk in the plant. Taking into account the maintenance dates, the time interval in which the analysis of the gas pre-coolers was carried out was established. With the registered plant data, the efficiency of these equipment was calculated during this period and an average efficiency was obtained that is approximately 30% less than the design efficiency for each one, this occurs because much of the gas that enters the exchangers bring with them shortchain polymers and when their temperature decreases, they solidify themselves, creating fouling that interferes in heat transfer. Finally, three improvement alternatives were proposed, simulated in Aspen Hysys v10, and the outlet temperatures of E2253A were compared in each one. A better result was obtained with improvement 3, which consists of circulating the gas simultaneously through both trains, since by decreasing the feed of each equipment, the speed of the fluid increases, increasing the overall heat transfer coefficient. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Químico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/11914 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
dc.publisher.program | Ingeniería Química | |
dc.publisher.school | Escuela de Ingeniería Química | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Intercambiadores de calor | |
dc.subject | Eficiencia energética | |
dc.subject | Planta de polietileno | |
dc.subject | Aspen Hysys | |
dc.subject.keyword | Heat Exchangers | |
dc.subject.keyword | Energy Efficiency | |
dc.subject.keyword | Polyethylene plant | |
dc.subject.keyword | Aspen Hysys | |
dc.title | Evaluación energética de los intercambiadores de sistema de media presión de la planta de Polietileno II de la Gerencia Refinería Barrancabermeja | |
dc.title.english | Energy assessment of the medium pressure system heat exchangers of the polyethylene ii plant of the Barrancabermeja refinery | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 148.61 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 21.11 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: