Influencia de la capacidad de disipación de energía seleccionada en el comportamiento sísmico y costo de edificios aporticados de concreto reforzado localizados en zonas de amenaza sísmica baja e intermedia en Colombia

dc.contributor.advisorBenjumea Royero, Jose Miguel
dc.contributor.advisorVillalba Morales, Jesus Daniel
dc.contributor.authorChaparro Tarazona, Andrea Carolina
dc.date.accessioned2024-03-03T23:27:41Z
dc.date.available2017
dc.date.available2024-03-03T23:27:41Z
dc.date.created2017
dc.date.issued2017
dc.description.abstractEn la NSR-10 se establece la capacidad de disipación de energía como parámetro importante en la configuración estructural del sistema de resistencia sísmica de una edificación, y su fin es permitir que la estructura disipe la energía que le induce un sismo a partir de la incursión de los materiales en rangos inelásticos. Este estudio presenta el análisis de edificios simétricos aporticados de concreto reforzado ubicados en zonas de amenaza baja e intermedia en Colombia, y el efecto que tiene sobre el comportamiento símico de los mismos y la determinación de los costos de materiales el elegir una capacidad de disipación de energía determinada. Se definen 20 casos de estudio, con edificaciones en las que se varía el número de pisos, longitud de vanos y el parámetro de disipación de energía, según se permite en la NSR-10, para zonas de amenaza baja e intermedia. Para cada caso de estudio se realiza el análisis y diseño respectivo, proponiendo una disposición de materiales (acero y concreto), según las solicitaciones en los elementos. Una vez se realizan los diseños se calculan las cantidades y costos de obra que corresponden al acero de refuerzo y concreto. Teniendo en cuenta los diferentes requisitos de disipación de energía, se llevan los análisis de ciertos casos a rangos no lineales en los que se definen las curvas de capacidad mediante el pushover. Los resultados de este trabajo establecen que el uso de diferentes criterios de disipación de energía en una misma edificación, aumenta o disminuye la cantidad de refuerzo que se dispone en los elementos principales del sistema estructural y por ende los costos de las mismas. Además se asocia un estado de daño característico en los elementos para cada elección de disipación de energía asignada al diseño de los mismos. 1
dc.description.abstractenglishThe Colombian Seismic Code- NSR 10 establishes the energy dissipation capacity as an important parameter in the structural design of buildings against seismic loads. This aims to allow the structure to dissipate the earthquake-induced energy by controlling the material performance into non-linear ranges. This study presents the analysis of symmetric reinforced concrete moment resisting frame buildings located in low and moderate seismic zones in Colombia in order to determine the effect of selecting a specific energy dissipation capacity on the seismic performance of the structure as well as on its global material cost. In this thesis, twenty structures were taken as case studies. Variations in the number of stories, the span length and the energy dissipation capacity were considered according to the NSR-10 Code. Each case study was firstly analyzed and designed under the code requirements. Secondly, the material quantities in terms of steel and concrete were calculated in order to compute the global material cost of each sample. Finally, the effect on the selection of the energy dissipation capacity was investigated by making a comparison of the material costs of the different typologies. The nonlinear static analysis, known as Pushover, was performed for specific samples taking into account the requirements for both low and moderate energy dissipation capacities. This type of analysis allows defining the expected damage levels of each the structure subjected to the design earthquake. The results of this study determined that the use of different criteria of energy dissipation in the same structure typology either decreases or increases the reinforcing steel in the structural members varying its global costs. Additionally, it was identified that a specific damage state characterizes the main structural members depending on the selected energy dissipation capabilities.
dc.description.degreelevelMaestría
dc.description.degreenameMagíster en Ingeniería Estructural
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/37080
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programMaestría en Ingeniería Estructural
dc.publisher.schoolEscuela de Ingeniería Civil
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectCapacidad De Disipación De Energía
dc.subjectComportamiento Sísmico
dc.subjectAnálisis No Lineal
dc.subjectPushover
dc.subjectCostos Materiales.
dc.subject.keywordEnergy Dissipation Capacity
dc.subject.keywordSeismic Response
dc.subject.keywordNon-Linear Analysis
dc.subject.keywordPushover
dc.subject.keywordMaterial Costs.
dc.titleInfluencia de la capacidad de disipación de energía seleccionada en el comportamiento sísmico y costo de edificios aporticados de concreto reforzado localizados en zonas de amenaza sísmica baja e intermedia en Colombia
dc.title.englishInfluence of the selected energy dissipation capacity on the structural seismic response and the cost of reinforced concrete buildings located in low and moderate sismic zones in colombia3
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_bdcc
dc.type.localTesis/Trabajo de grado - Monografía - Maestria
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
318.51 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
2.86 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
65.79 KB
Format:
Adobe Portable Document Format