Práctica empresarial en ACIEND S.A.S como apoyo a la evaluación de problemas en la calibración de equipos de Ultrasonido (Phased Array) e implementación de técnica por C-scan para inspección de soldaduras y daños por corrosión
dc.contributor.advisor | Galán Pinilla, Carlos Andrés | |
dc.contributor.author | Muñoz Ríos, Maure Loraine | |
dc.contributor.evaluator | González Hernández, Andrés Giovanni | |
dc.contributor.evaluator | Pérez Ceballos, Ana María | |
dc.date.accessioned | 2022-04-20T21:16:33Z | |
dc.date.available | 2022-04-20T21:16:33Z | |
dc.date.created | 2022-03-30 | |
dc.date.embargoEnd | 2027-03-30 | |
dc.date.issued | 2022-03-30 | |
dc.description.abstract | La técnica de Ensayo No Destructivo (END) de Ultrasonido por Phased Array o arreglo de fases, es ampliamente utilizada en la industria petroquímica, para evaluar la calidad de juntas soldadas y accesorios de tuberías, entre otros componentes. Está técnica avanzada de inspección hace parte de los servicios prestados por la empresa ACIEND SAS ubicada en Barrancabermeja-Santander. Además cuenta con otras técnicas convencionales de inspección. Con el desarrollo de la presente práctica empresarial, se estudiaron fallas reportadas con respecto a los procesos de calibración de los equipos de Ultrasonido, con el fin de identificar las variables o parámetros que provocan la incorrecta calibración. Para esto se evaluaron a los tres inspectores que prestan sus servicios de forma permanente en ACIEND S.A.S, de lo cual, se evidenció que existen daños de Software, deterioro de las zapatas y por mejorar habilidad por parte de un inspector. Como resultado de la caracterización de equipos se identificó que la empresa puede ampliar su portafolio de servicios en la identificación de corrosión por medio de la aplicación de C-scan, para lo cual se requiere realizar una inversión en nuevos palpadores y zapatas, con la finalidad de efectuar la técnica a los diámetros de servicio más comunes ofertados en la empresa (3, 6 y 8 pulg). Finalmente, la preparación obtenida durante la práctica mediante capacitaciones, realización de certificaciones y ejecución de los ensayos en campo, permitieron la participación en diversos proyectos, entre ellos, el proyecto de evaluación de integridad del gasoducto Payoa-Galán de la empresa Petrosantander, en el que participé durante la etapa de inspección, análisis y discusión del caso de estudio, en el cual, se identificaron diversos mecanismos de daño mecánicos y por corrosión; los cuales fueron evaluados bajo norma y son reportados en el presente informe. | |
dc.description.abstractenglish | The Phased Array Ultrasound Non-Destructive Testing (NDT) technique is widely used in the petrochemical industry to assess the quality of welded joints and pipe fittings, among other components. This advanced inspection technique is part of the services provided by the company ACIEND SAS located in Barrancabermeja-Santander, in addition to other conventional inspection techniques. When developing the business practice, it was evidenced that the company had flaws with respect to the calibration processes of the Ultrasound equipment, for which the basic variables that caused the incorrect calibration were identified; evaluated to the three inspectors who provide their services in ACIEND S.A.S, of which, Software damage, deterioration of the shoes and skill on the part of an inspector were evidenced. As a result of the characterization of equipment, it was identified that the company can expand its portfolio of services in the identification of corrosion through the application of C-scan, for which it is required to make an investment in new probes and shoes, with the purpose to carry out the technique to the most common service diameters offered in the company (3, 6 and 8 inches). Finally, the preparation obtained during the internship through training, certifications and execution of field tests, allowed participation in various projects, including the Petrosantander company's Payoa-Galán gas pipeline integrity assessment project, in the that I participated during the inspection, analysis and discussion stage of the case study, in which various mechanical and corrosion damage mechanisms were identified; which were evaluated under the standard and are reported in this report. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Metalúrgico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/10089 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingeníerias Fisicoquímicas | |
dc.publisher.program | Ingeniería Metalúrgica | |
dc.publisher.school | Escuela de Ingeniería Metalúrgica y Ciencia de Materiales | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Aciend SAS | |
dc.subject | Ensayos no Destructivos | |
dc.subject | Ultrasonido Phased Array | |
dc.subject | Calibración | |
dc.subject | C-scan | |
dc.subject | Industria petroquímica | |
dc.subject.keyword | ACIEND S.A.S | |
dc.subject.keyword | Non-Destructive Testing | |
dc.subject.keyword | Ultrasound Phased Arrays | |
dc.subject.keyword | calibration | |
dc.subject.keyword | C-scan | |
dc.subject.keyword | petrochemical industry | |
dc.title | Práctica empresarial en ACIEND S.A.S como apoyo a la evaluación de problemas en la calibración de equipos de Ultrasonido (Phased Array) e implementación de técnica por C-scan para inspección de soldaduras y daños por corrosión | |
dc.title.english | Business internship at ACIEND S.A.S as support for the evaluation of problems in the calibration of Ultrasound equipment (Phased Array) and implementation of C-scan technique for inspection of welds and corrosion damage | |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado | |
dspace.entity.type |
Files
Original bundle
1 - 4 of 4
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 205.92 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- Carta de confidencialidad.pdf
- Size:
- 136.1 KB
- Format:
- Adobe Portable Document Format
- Description:
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 179.84 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 2.18 KB
- Format:
- Item-specific license agreed to upon submission
- Description: