Evaluación del factor de capacidad de disipación de energía de edificios altos de muros industrializados delgados y esbeltos

dc.contributor.advisorLeón Bonett Díaz, Ricardo
dc.contributor.authorZea Acevedo, Mayra Alejandra
dc.date.accessioned2024-03-04T01:22:27Z
dc.date.available2021
dc.date.available2024-03-04T01:22:27Z
dc.date.created2021
dc.date.issued2021
dc.description.abstractEn respuesta al crecimiento poblacional y la demanda de vivienda se ha observado en la actualidad un incremento significativo de construcción de edificios con sistema de muros industrializados, debido a la reducción en tiempos y costos de construcción frente a otros sistemas constructivos y su aprovechamiento de espacios, no obstante, esta misma practica ha impulsado el uso de muros delgados, en algunos casos con ausencia de confinamiento. Este hecho ha alarmado a la comunidad académica en todo el mundo debido a que en sismos recientes como los ocurridos en Chile (2010), Nueva Zelanda (2011) y Turquía (2010), se evidenció una respuesta desfavorable de edificios de muros con sistemas de muros con características similares e incluso mejores de las encontradas en la Ciudad de Bucaramanga. Debido a esta preocupación se han realizado numerosas investigaciones con el fin de estudiar la respuesta de este sistema estructural ante eventos sísmicos de gran magnitud. En este trabajo, se analizó una base datos de 26 edificios localizados en zona de amenaza sísmica alta, principalmente en la ciudad de Bucaramanga, a partir de los macro parámetros de cada uno de los edificios, y finalmente se obtuvo la curva de capacidad para dos de ellos, con base en su configuración, cargas aplicadas y detallado de refuerzo. A partir de los resultados obtenidos, se identificó la necesidad de revisar algunos aspectos normativos, como el factor de capacidad de disipación de energía, R. ya que el uso de factores inapropiados que sobre estimen la capacidad de la estructura, puede conducir a diseños estructurales con bajos niveles de seguridad. A partir de las características identificadas de los macro parámetros de los edificios localizados en zonas de amenaza sísmica alta, se obtuvieron funciones de distribución de probabilidad para los principales parámetros geométricos y mecánicos que controlan el comportamiento sísmico de los edificios. A partir de estas funciones y por medio de una metodología simplificada de análisis estático no lineal, se desarrollaron curvas de capacidad para edificios con alturas entre 15 y 20 niveles, a partir de las cuales fue posible determinar el coeficiente de capacidad de energía y sobre resistencia de cada caso. Los resultados obtenidos muestran que los coeficientes de disipación obtenido en este trabajo son inferiores a los considerados por el Reglamento Colombiano de Construcción Sismo Resistente (Asociación Colombiana de Ingeniería Sísmica, 2010) haciéndose necesaria una reevaluación de las consideraciones de diseño establecidas para esta tipología de estructura, teniendo en cuenta que se podría estar sobreestimando la capacidad de las edificaciones.
dc.description.abstractenglishThe grown of population and housing demand have increased the construction of reinforced concrete structural wall buildings. The use of this structural system not only allows to reduce the construction time and cost, also improves the use of space in comparison with other construction systems. However, the popularity of this system has motivated the use of thin, lightly reinforced concrete walls with a poor or nonexistent confinement detailing at the walls edges. This fact has caught the attention of the academic community worldwide because recent earthquakes as those happened in Chile (2010), New Zealand (2011) and Turkey (2010), it was observed an inadequate response of thin reinforced concrete structural wall buildings with similar characteristics and even better than used in Bucaramanga, Colombia. This study comprises data from 26 buildings located mainly in Bucaramanga city (Colombia), which correspond to high seismic hazard zone. The study was based on macroparameters of each building and it let to calculate the capacity curve for two of them, based on their configuration, applied loads and reinforcement. According to the results obtained, it was identified the need the review of some normative aspects as the energy dissipation coefficient, R because the use of an inadequate value overestimate the capacity of the structures can lead to designs with low safety levels. Probability distribution functions for the main geometric and mechanic parameters that define the seismic behavior of the buildings were obtained from statistical analyses of database. These probability distribution functions were used to generate theoretical structural models representative of building between 15 to 20stories and then, a nonlinear static simplified methodology was developed to estimate the capacity curve of each building. These curves were used to calculate the energy dissipation and overresistance coefficients for each building. The results show that the coefficients obtained are lower than the specified on the Colombian Construction Code, NSR10. A review of values proposed by NSR10 for reinforced concrete buildings is needed to avoid a overestimate of the structural capacity which could lead to an insecure seismic structural design.
dc.description.degreelevelMaestría
dc.description.degreenameMagíster en Ingeniería Estructural
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/41979
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Ingenierías Fisicomecánicas
dc.publisher.programMaestría en Ingeniería Estructural
dc.publisher.schoolEscuela de Ingeniería Civil
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectMuros de concreto reforzado
dc.subjectBase de datos
dc.subjectFactor de capacidad de disipación de energía
dc.subjectEsbeltez
dc.subjectConfinamiento
dc.subjectsobre resistencia.
dc.subject.keywordThin walls
dc.subject.keywordReinforced concrete
dc.subject.keywordDatabase
dc.subject.keywordShear walls
dc.subject.keywordDuctility
dc.subject.keywordreduction factor
dc.subject.keywordoverstrength
dc.titleEvaluación del factor de capacidad de disipación de energía de edificios altos de muros industrializados delgados y esbeltos
dc.title.englishEvaluación del factor de capacidad de disipación de energía de edificios altos de muros industrializados delgados y esbeltos *
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_bdcc
dc.type.localTesis/Trabajo de grado - Monografía - Maestria
Files
Original bundle
Now showing 1 - 3 of 3
No Thumbnail Available
Name:
Carta de autorización.pdf
Size:
106.81 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Documento.pdf
Size:
3.88 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
137.18 KB
Format:
Adobe Portable Document Format