Determinacion de valores de pulso-oximetria en recien nacidos sanos en el hospital universitario ramon gonzalez valencia de bucaramanga

dc.contributor.advisorNiederbacher Velasquez, Jurg
dc.contributor.authorGarrido Vecino, Hector
dc.date.accessioned2024-03-03T04:35:47Z
dc.date.available2004
dc.date.available2024-03-03T04:35:47Z
dc.date.created2004
dc.date.issued2004
dc.description.abstractLa pulso-oximetría, es un método rápido, sencillo, económico, no-invasivo y eficaz para determinar indirectamente la saturación arterial de oxígeno. Su valor está influenciado por factores como altitud, hallándose cifras diferentes según la distancia sobre nivel del mar a la cual se haga la determinación. Bucaramanga está localizada a 960 m.s.n.m. No se conocen valores promedios para R.N.S. a ésta altitud. Determinar valores de referencia propia conduce a optimizar el manejo de R.N. que necesiten o reciban oxigenoterapia, tomándolos como referencia para otras investigaciones. El propósito del trabajo fue determinar valores de pulso-oximetría en una población de R.N.S. en las primeras doce horas de vida, residentes en Bucaramanga. Se realizó una muestra de 150 maternas con sus R.N., escogidos por conveniencia de acuerdo a criterios de inclusión predeterminados, en el H.U.R.G.V., creando dos grupos según edad del R.N. (< 6 y de 6-12 horas de vida). Se utilizó un pulso-oxímetro marca Palco, modelo 305A, con sensor pediátrico, colocado en el dorso del segundo dedo del pie derecho; se tomaron 3 mediciones y eligiendo como cifra hallada el promedio de las tres. Se analizaron los datos con Epiinfo-6.04 y Stata-6. Se encontró una saturación promedio de 96,50% (D.S. 1,50) con valores mínimo de 92% y máximo de 100% en las primeras 6 horas de vida y de 96,56% (D.S. 1,58) con valores mínimo de 92% y máximo de 100% entre las 6-12 horas de vida, con diferencias estadísticamente significativas según edad de gestación por amenorrea o por método de Ballard (p< 92% y las cifras de saturación de oxígeno puedan descender dependiente de la edad gestacional. Además de la discusión de resultados se hace una revisión de los usos y limitaciones de la pulso-oximetría.
dc.description.abstractenglishPulse oximetry is a fast, simple, economic, non-invasive, and efficient method to determine the arterial saturation of oxygen indirectly. Its value is influenced by altitude, among other factors. Different values according to the distance above the sea level at which the determination is made. Bucaramanga is locate at 960 meter above the sea level. Average values for newborn babies are unknown at this altitude. The determination of characteristic reference values leads to the optimization of newborn babies management, who require or receive oxygen therapy. These values, then, will be considered as reference points for future research. The objective of this research paper is to determine the pulse oximetry values in a population of healthy newborn babies living in Bucaramanga, during their first twelve hours of life. A sample of 150 mothers with their newborn babies at the Ramon Gonzalez Valencia University Hospital was selected according to pre-determined inclusion criteria. Two groups of newborn babies were established (less than 6 hours old and from 6 to 12 hours old). A Palco-brand, 305A Model, Pulse oximeter with pediatric sensor was used. This device was placed on the dorsal surface of the second toe, in the right foot. Three measurements were taken and averaged. Data were analyzed using Epiinfo-6.4 and Stata-6 software. An average saturation of 96.50% (SD = 1.50) was found during the first six hours of life, with a minimum value of 92% and a maximum value of 100%; An average saturation value of 96.56% (SD = 1.58) was found in the group aging from 6-12 hours of life, with a minimum value of 92% and a maximum value of 100%. Statistically significant differences were found according to the gestation age that was determined by amenorrhea or by the Ballard’s Method (p< 92%. Saturation figures can decrease depending on the gestational age. In addition to the discussion of results, a review of the uses and limitations of pulse oximetry is made.
dc.description.degreelevelEspecialización
dc.description.degreenameEspecialista en Pediatría
dc.format.mimetypeapplication/pdf
dc.identifier.instnameUniversidad Industrial de Santander
dc.identifier.reponameUniversidad Industrial de Santander
dc.identifier.repourlhttps://noesis.uis.edu.co
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/16073
dc.language.isospa
dc.publisherUniversidad Industrial de Santander
dc.publisher.facultyFacultad de Salud
dc.publisher.programEspecialización en Pediatría
dc.publisher.schoolEscuela de Medicina
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0
dc.subjectNiño sano
dc.subjectPulso-oximetría
dc.subjectHemoglobina
dc.subjectSaturación arterial de oxigeno
dc.subject.keywordHealthy baby
dc.subject.keywordPulse oximetry
dc.subject.keywordHemoglobin
dc.subject.keywordArterial saturation of oxygen
dc.titleDeterminacion de valores de pulso-oximetria en recien nacidos sanos en el hospital universitario ramon gonzalez valencia de bucaramanga
dc.title.englishDetermination of pulsooximetry values in healthynewborn babies at the ramon gonzalez valenciauniversity hospital (h.u.r.g.v.) of
dc.type.coarhttp://purl.org/coar/version/c_b1a7d7d4d402bcce
dc.type.hasversionhttp://purl.org/coar/resource_type/c_7a1f
dc.type.localTesis/Trabajo de grado - Monografía - Pregrado
Files
Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Documento.pdf
Size:
1009.11 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Nota de proyecto.pdf
Size:
335.93 KB
Format:
Adobe Portable Document Format