Acondicionamiento del efluente acuoso proveniente del d-2604 del departamento de refinación de fondos de la grb, para su uso como agua de calderas
dc.contributor.advisor | Nabarlatz, Débora Álcida | |
dc.contributor.author | García Rueda, July Andrea | |
dc.date.accessioned | 2024-03-03T22:10:34Z | |
dc.date.available | 2015 | |
dc.date.available | 2024-03-03T22:10:34Z | |
dc.date.created | 2015 | |
dc.date.issued | 2015 | |
dc.description.abstract | En la planta de Generación de Hidrógeno del Departamento de Refinación de Fondos de la GRB, se está vertiendo un condensado ácido al sistema de aguas lluvias, proveniente del mismo proceso, en el tambor separador D-2604. Este efluente está generando los siguientes impactos desfavorables: daño a la comunidad y al ecosistema del Rio Magdalena por el desequilibrio en la fauna y flora generado, aceleración de la corrosión en las tuberías aguas abajo e impedimento de reutilización por daño corrosivo en la metalurgia de los equipos, deterioro del concreto alrededor del equipo en cuestión y mal aspecto visual de la planta, además del detrimento económico por falta de reutilización del efluente, que previo al proceso de generación de hidrógeno pasa por todo el tratamiento fisicoquímico de aguas de calderas. A través de la práctica industrial realizada se evalúan técnica y económicamente dos alternativas con el fin de acondicionar el efluente en cuestión para enviarlo al desaireador DH-2951 de la Unidad de Servicios Industriales Balance, y darle uso como agua de calderas. Las alternativas consideradas fueron: realizar desaireación térmica mediante la adecuación de la torre F-2602C (la cual se encuentra en desuso y desmantelada desde hace varios años) para usarla como desaireador, y realizar la desaireación química eliminando el CO2 disuelto en el mismo tambor separador D-2604. Con ambas alternativas se logra eliminar el CO2 disuelto y subir el pH del efluente a 8.8, sin embargo el estudio económico muestra que la alternativa 2 tiene el factor j más alto, lo que quiere decir que genera mayor beneficio económico al departamento de Refinación de Fondos. Se recomienda la implementación de la alternativa 2 porque además de ser más rentable, su montaje y operación es más sencillo. | |
dc.description.abstractenglish | In the hydrogen generation plant of the Bottoms Refining Department of the GRB, a condensed acid is pouring into the rainwater system, which comes from the same process, through the D-2604 separator drum. This effluent is generating the following unfavorable impacts: community and ecosystem damage of the Magdalena River caused by the fauna and flora disequilibrium that is generated, accelerating the pipeline corrosion downstream, reuse impediment due to the corrosive concrete deterioration around that equipment and an unsightly plant. Furthermore, it also caused an economical detriment due to the lack of the effluent reuse, which before the hydrogen generation process, it passes through the water boilers physicochemical treatment. Two alternatives were technically and economically evaluated through the industrial practice developed to condition the effluent mentioned above with the aim of send it to the DH-2951 deaerator of the Balance Industrial Services Unity and use it as a water boilers. The considered alternatives were: thermal deaeration through the adequacy of the F-2602C tower (which is not being used and it was dismantled many years ago) to use it as a deaerator and the chemical deaeration which consists in remove the dissolved CO2 in the same D-2604 separator drum. The final outcome with both alternatives was the removal of the dissolved CO2 and the increasing of the pH effluent to 8.8, however the economical studied showed that the second alternative has the highest j factor, namely, it generates the greatest economic benefit for the Bottoms Refining Department. It is recommended the second alternative implementation due to the fact that not only has an easy assembly and operation but it is more profitable as well. | |
dc.description.degreelevel | Pregrado | |
dc.description.degreename | Ingeniero Químico | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/33053 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
dc.publisher.program | Ingeniería Química | |
dc.publisher.school | Escuela de Ingeniería Química | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Desaireación Térmica Y Química | |
dc.subject | Co2 Disuelto. | |
dc.subject.keyword | Thermal And Chemical Deaeration | |
dc.subject.keyword | Co2 Dissolved. | |
dc.title | Acondicionamiento del efluente acuoso proveniente del d-2604 del departamento de refinación de fondos de la grb, para su uso como agua de calderas | |
dc.title.english | Conditioning of the aqueous effluent from the d-2604 in the bottoms refining department belonging to the grb, to use it as a heating fluid | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |
Files
Original bundle
1 - 3 of 3
No Thumbnail Available
- Name:
- Carta de autorización.pdf
- Size:
- 133.86 KB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Nota de proyecto.pdf
- Size:
- 130.8 KB
- Format:
- Adobe Portable Document Format