New methodology in Holter evaluation based on dynamics systems and fractal geometry: confirmation of its applicability at clinical level

dc.creatorRodríguez V., Javier O.
dc.creatorPrieto B., Signed E.
dc.creatorCorrea H., Sandra C.
dc.creatorSoracipa M., María Y.
dc.creatorMéndez P., Laura R.
dc.creatorBernal C., Hebert J.
dc.creatorHoyos O., Natalia C.
dc.creatorValero, Laura P.
dc.creatorVelasco R., Alejandro
dc.creatorBermudez, Eduardo
dc.date2016-02-11
dc.date.accessioned2022-03-14T20:31:41Z
dc.date.available2022-03-14T20:31:41Z
dc.descriptionIntroducción: La teoría de sistemas dinámicos establece medidas cuantitativas de evolución de los sistemas mediante la construcción de atractores. Medidas de ocupación espacial de atractores cardiacos en el espacio fractal de Box Counting diferenciaron normalidad y enfermedad crónica de enfermedad aguda. Objetivo: Aplicar la metodología desarrollada para evaluar matemáticamente el estado cardiaco de Holter con diferentes patologías, confirmando la aplicabilidad de esta metodología para la detección de dinámicas agudas mediante medidas de concordancia estadística respecto al Gold Standard. Metodología: Se analizaron 170 Holter, incluyendo normales, crónicos y en estado agudo. Se construyeron simulaciones de la totalidad de la dinámica basada en número de latidos y frecuencia mínima y máxima cada hora durante 21 horas, para construir atractores en el espacio de fases. Se calculó la dimensión fractal de los atractores evaluando su ocupación espacial en el espacio de Box Counting, estableciendo cuáles corresponden a normalidad y enfermedad aguda de acuerdo con resultados matemáticos previos. Se comparó el diagnóstico matemático con el diagnóstico convencional del Holter, tomado como Gold Standard, estableciendo valores de sensibilidad, especificidad y coeficiente Kappa. Resultados: La dimensión fractal no logró evidenciar diferencias cuantitativas mientras que la metodología detectó en todos los casos dinámicas normales y en estado agudo independientemente de la patología, logrando valores de sensibilidad, especificidad, valor predictivo positivo y negativo de 100%, y coeficiente Kappa de 1. Conclusiones: Se confirmó la capacidad de la metodología físico-matemática para detectar dinámicas agudas independientemente de la patología asociada, confirmando una auto-organización acausal de la dinámica del sistema cuya evaluación permite establecer medidas de aplicabilidad clínica.  es-ES
dc.descriptionIntroduction: Dynamic systems theory provides quantitative measures of evolution of systems by building attractors. Spatial occupation measures of cardiac attractors in fractal Box Counting space differentiated normality and chronic disease from acute illness. Objective: To apply the developed methodology to evaluate mathematically the cardiac status of Holter with different pathologies, confirming the applicability of this methodology for the detection of acute dynamic by statistical measures of agreement regarding the Gold Standard. Methodology: 170 Holter, including normal, chronic and in acute states were evaluated. Simulations were constructed the entire dynamic based on the number of beats and the minimum and maximum frequencies every hour for 21 hours, to build attractors in the phase space. The fractal dimension of attractors is calculated, evaluating the spatial occupation in the Box Counting space, establishing which corresponds to normal setting and acute disease in accordance with previous mathematical results. Mathematical diagnosis was compared with conventional diagnostic Holter, taken as the Gold Standard, setting sensitivity, specificity, positive and negative predictive value and Kappa coefficient. Results: The fractal dimension failed to show quantitative differences while the methodology detected in all cases normal dynamics and acute state independently of the disease, achieving sensitivity, specificity, positive and negative predictive value of 100% and a Kappa 1. Conclusions: the ability of the physical-mathematical methodology to detect acute dynamic regardless of the associated pathology was confirmed, as well as an acausal self-organization of the system dynamics, which allows for assessment of clinical applicability measures.en-US
dc.formatapplication/pdf
dc.formattext/html
dc.identifierhttps://revistas.uis.edu.co/index.php/revistasaluduis/article/view/5399
dc.identifier10.18273/revsal.v48n1-2016003
dc.identifier.urihttps://noesis.uis.edu.co/handle/20.500.14071/8837
dc.languagespa
dc.publisherUniversidad Industrial de Santanderes-ES
dc.relationhttps://revistas.uis.edu.co/index.php/revistasaluduis/article/view/5399/5648
dc.relationhttps://revistas.uis.edu.co/index.php/revistasaluduis/article/view/5399/5960
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.coarhttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rights.licenseAttribution-NonCommercial 4.0 International (CC BY-NC 4.0)
dc.sourceSalud UIS; Vol. 48 Núm. 1 (2016): Revista Salud UISes-ES
dc.sourceSalud UIS; Vol. 48 No. 1 (2016): Revista Salud UISen-US
dc.sourceSalud UIS; v. 48 n. 1 (2016): Revista Salud UISpt-BR
dc.source2145-8464
dc.source0121-0807
dc.subjectHeart rateen-US
dc.subjectdiagnosisen-US
dc.subjectnonlinear dynamicsen-US
dc.subjectfractalsen-US
dc.subjectFrecuencia cardiacaes-ES
dc.subjectdiagnósticoes-ES
dc.subjectdinámicas no linealeses-ES
dc.subjectfractaleses-ES
dc.titleNew methodology in Holter evaluation based on dynamics systems and fractal geometry: confirmation of its applicability at clinical levelen-US
dc.titleNueva metodología de evaluación del Holter basada en los sistemas dinámicos y la geometría fractal: confirmación de su aplicabilidad a nivel clínicoes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dspace.entity.type
Files