Estudio de las tecnologías para el control de dew point de la corriente de gas natural producida en la estación tocaria de Perenco Colombia limited
dc.contributor.advisor | Santos Santos, Nicolás | |
dc.contributor.author | Villacreces Arenas, Luis Carlos | |
dc.contributor.author | Amado Duarte, Diana Carolina | |
dc.date.accessioned | 2024-03-03T21:55:53Z | |
dc.date.available | 2015 | |
dc.date.available | 2024-03-03T21:55:53Z | |
dc.date.created | 2015 | |
dc.date.issued | 2015 | |
dc.description.abstract | La Estación Tocaría de la empresa de producción y exploración de petróleo “Perenco Colombia Limited”, está ubicada en la Vereda del Taladro jurisdicción del municipio de Yopal, Departamento de Casanare. Actualmente tiene una producción de 158 Bbls de crudo y 8 MMscfd de gas natural sin procesar de los cuales se transporta 6 MMscfd por gasoducto a las demás estaciones para apoyar el sistema de levantamiento artificial de gas lift y 2 MMscfd son usados para auto generación. Este gas no posee condiciones de calidad requeridas en el RUT, pues se evidencia presencia de líquidos, los cuales ocasionan altos costos por mantenimientos no planeados, así como un impacto significativo en la confiabilidad del sistema de generación eléctrica y compresión para el sistema de gas lift. Con el objetivo de comparar las tecnologías utilizadas para la recuperación de líquidos hidrocarburos desde el gas natural, se realizaron varias corridas con el fin de evaluar las ventajas y desventajas de las diferentes alternativas propuestas (Refrigeración Mecánica con propano, enfriamiento con JouleThomson y Turboexpander convencional). Se evaluó el recobro de líquidos hidrocarburos alcanzado (nafta y GLP), las temperaturas de formación de hidratos con cada inhibidor, el requerimiento de recompresion, el trabajo en el compresor-expansor y la energía del chiller. Lo anterior debido a que todos estos parámetros no solo representan una parte significativa del capital requerido, sino también se constituyen en un indicativo clave de la energía a utilizar en las facilidades. De acuerdo a los resultados obtenidos la tecnología más eficiente corresponde a turbo expander. Con este proceso se obtiene una remoción superior al 85% del etano y esencialmente de todos los hidrocarburos más pesados hallados en el gas natural producido, para el caso de estudio se obtuvo una recuperación de líquidos de 385,4 Bbls/dia de GLP y 84,03 Bbls/dia de Nafta. | |
dc.description.abstractenglish | The station Tocaria of the company's production and exploration of oil "Perenco Colombia Limited" is located in the village of the drill (Vereda del Taladro) municipality of Yopal, in the Department of Casanare. Currently it has an output of 158 Bbls of oil and 8 MMscfd of raw natural gas which is transported 6 MMscfd by pipeline to the other stations to support the system of artificial lift of gas lift and 2 MMscfd are used for auto generation. This gas does not have required quality conditions in the RUT, because there is evidence of the presence of liquids, which cause high costs for unplanned maintenance, as well as a significant impact on system reliability of power generation and compression for the gas lift system. In order to compare the technologies used for the recovery of liquid hydrocarbons from natural gas, several runs were conducted to evaluate the advantages and disadvantages of the various alternatives proposed (Mechanical Refrigeration propane, Joule-Thomson cooling and conventional turboexpander). The recovery of liquid hydrocarbons reached (naphtha and LPG), temperatures of hydrate formation with each inhibitor, the requirement for recompression, work on the compressor-expander and the chiller energy was evaluated. This because all these parameters not only represent a significant part of the required capital, but also constitute a key indicator of the energy used in the facilities. According to the results the most efficient technology corresponds to turbo expander. This process is obtained a greater than 85% removal of ethane and essentially of all heavier hydrocarbons found in natural gas produced, for the case study, it was obtained a liquid recovery of 385.4 Bbls / day of LPG and 84,03 Bbls / day of Nafta. | |
dc.description.degreelevel | Especialización | |
dc.description.degreename | Especialista en Ingeniería del Gas | |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | Universidad Industrial de Santander | |
dc.identifier.reponame | Universidad Industrial de Santander | |
dc.identifier.repourl | https://noesis.uis.edu.co | |
dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/31838 | |
dc.language.iso | spa | |
dc.publisher | Universidad Industrial de Santander | |
dc.publisher.faculty | Facultad de Ingenierías Fisicoquímicas | |
dc.publisher.program | Especialización en Ingeniería del Gas | |
dc.publisher.school | Escuela de Ingeniería de Petróleos | |
dc.rights | http://creativecommons.org/licenses/by/4.0/ | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
dc.rights.license | Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0 | |
dc.subject | Dew Point De Hidrocarburos | |
dc.subject | Refrigeración Mecánica | |
dc.subject | Autorefrigeración | |
dc.subject | Refrigeración Criogénica | |
dc.subject | Válvula Joule Thomson | |
dc.subject | Turboexpander Y Recuperación De Líquidos De Gas Natural. | |
dc.subject.keyword | Dew Point Hydrocarbons | |
dc.subject.keyword | Refrigeration Mechanic | |
dc.subject.keyword | Auto-Refrigeration | |
dc.subject.keyword | Cryogenic Refrigeration | |
dc.subject.keyword | Joule Thomson Valve | |
dc.subject.keyword | Turboexpander And Recovery Of Natural Gas Liquids. | |
dc.title | Estudio de las tecnologías para el control de dew point de la corriente de gas natural producida en la estación tocaria de Perenco Colombia limited | |
dc.title.english | Study of technologies for control of dew point of the stream of natural gas produced at the station tocaria de perenco Colombia limited | |
dc.type.coar | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
dc.type.hasversion | http://purl.org/coar/resource_type/c_7a1f | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Pregrado |