Publicación: Reducción de la carga térmica mediante la instalación de cortinas de aire
| dc.contributor.advisor | Jaramillo Ibarra, Julián Ernesto | |
| dc.contributor.author | Sánchez Carvajal, German Mauricio | |
| dc.contributor.author | Palma Pacheco, Yeciht Robert | |
| dc.contributor.evaluator | Amaris Castilla, Carlos Fidel | |
| dc.date.accessioned | 2025-12-10T21:33:49Z | |
| dc.date.available | 2025-12-10T21:33:49Z | |
| dc.date.created | 2025-10-18 | |
| dc.date.issued | 2025-10-18 | |
| dc.description.abstract | Nuestro cliente el cual pertenece al sector bancario, debido a los cambios en su nueva imagen corporativa (imagen tipo I’AM) se vio en la necesidad de modificar la arquitectura de sus fachadas en la zona de autoservicio para las nuevas oficinas, como es el caso de la oficina Centro Comercial Mall Plaza Cali. La nueva distribución arquitectónica permite el ingreso de aire exterior no controlado hacia el interior de la oficina, generando esto un aumento aproximado de 3 grados Celsius en la temperatura ambiente al interior de esta. Para contrarrestar lo planteado, se ha hecho necesario aumentar la capacidad y cantidad de los equipos de aire acondicionado instalados en la mayoría de las nuevas oficinas implementadas con la arquitectónica corporativa mencionada. Con el fin de disminuir los costos del consumo eléctrico de los sistemas hvac que serán implementados en las nuevas oficinas I’AM, propusimos a nuestro cliente la inclusión de equipos de ventilación mecánica tipo cortina, los cuales podrán ser instalados sobre los vanos de la entrada principal y dinteles existentes en las zonas de acceso del hall de cajeros de clientes pretendiendo disminuir el ingreso de aire exterior no controlado hacia el interior de la oficina y así poder demostrarle al cliente, la disminución en el consumo eléctrico del sistema hvac instalado en este tipo de oficinas. Una vez nuestro cliente dio la autorización, procedimos a incluir en nuestro diseño hvac (oficina Centro Comercial Mall Plaza Cali) las costinas de aire propuestas la cuales debíamos calcular y dimensionar respecto a la altura permitida y medidas de las puertas de ingreso existentes. El principal resultado que arrojo este estudio, fue poder demostrarle a nuestro cliente que podrá obtener un ahorro anual de $ 3.401.800 en el pago del servicio de energía lo podría garantizarle también, un retorno de la inversión a un menor tiempo de lo planeado. Aun cuando este trabajo no se basó fundamentalmente en demostrarle al cliente la diminución de los costos de inversión respecto a la posibilidad de disminuir las capacidades de los equipos de aire a implementar en futuros proyectos, fue claro para nuestro usuario que aparte del ahorro en dinero referente a la disminución del consumo eléctrico, también estaría entre su seguimiento interno demostrar que su costo de inversión en infraestructura disminuiría al momento de implementar en sus instalaciones hvac, equipos tipo cortinas de aire. | |
| dc.description.abstractenglish | Our client, who belongs to the banking sector, due to the changes in its new corporate image, found it necessary to modify the architecture of its facades in the self-service area for the new offices, as is the case of the Shopping Center office. Mall Plaza Cali. The new architectural distribution allows the entry of uncontrolled outside air into the office, generating an approximate increase of 3 degrees Celsius in the ambient temperature inside it. To counteract the above, it has become necessary to increase the capacity and quantity of air conditioning equipment installed in the majority of the new offices implemented with the aforementioned corporate architecture. The main result of this study was to demonstrate to our client that they could achieve annual savings of $3,401,800 in energy service payments, which would also guarantee a return on investment in less time than planned. Even though our work was not primarily based on demonstrating to the client the reduction in investment costs with respect to the possibility of reducing the capacity of the air conditioning equipment to be implemented in future projects, it was clear to our user that, apart from the monetary savings related to the reduction in electricity consumption, it would also be part of their internal monitoring to demonstrate that their investment cost in infrastructure would decrease when implementing air curtain-type equipment in their HVAC facilities. | |
| dc.description.degreelevel | Especialización | |
| dc.description.degreename | Especialista en Ingeniería de Refrigeración y Climatización | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/46854 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingenierías Fisicomecánicas | |
| dc.publisher.program | Especialización en Ingeniería de Refrigeración y Climatización | |
| dc.publisher.school | Escuela de Ingeniería Mecánica | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Cortinas de aire | |
| dc.subject.keyword | Air Curtains | |
| dc.title | Reducción de la carga térmica mediante la instalación de cortinas de aire | |
| dc.title.english | Thermal Load Reduction by Installing Air Curtains | |
| dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 4 de 4
Cargando...
- Nombre:
- Nota de proyecto 1.pdf
- Tamaño:
- 144.3 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- German Mauricio Sánchez Carvajal
Cargando...
- Nombre:
- Nota de proyecto 2.pdf
- Tamaño:
- 163.23 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Yecith Robert Palma
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 190.13 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción: