Publicación: COMPRESIÓN DE MODELOS BASADOS EN APRENDIZAJE PROFUNDO PARA LA DETECCIÓN DE LA FIBRILACIÓN AURICULAR
| dc.contributor.advisor | FAJARDO ARIZA, CARLOS FAJARDO | |
| dc.contributor.author | CASTILLO BOHORQUEZ, JEYSON ARLEY | |
| dc.contributor.evaluator | SEPÚLVEDA, FRANKLIN ALEXANDER | |
| dc.contributor.evaluator | SERRANO, JHEYSTON OMAR | |
| dc.date.accessioned | 2026-06-12T21:08:32Z | |
| dc.date.created | 2026-06-09 | |
| dc.date.embargoEnd | 2027-06-09 | |
| dc.date.issued | 2026-06-09 | |
| dc.description.abstract | En la actualidad, se observa una disminución en la tasa de acceso a los servicios de salud en todos los países, principalmente debido al crecimiento poblacional a escala global. Como resultado, la tasa de mortalidad por enfermedades que requieren servicios de diagnóstico especializado ha aumentado. Entre los casos más preocupantes se encuentran las enfermedades cardíacas isquémicas, que son una de las principales causas de mortalidad a nivel mundial. Este es el caso de las arritmias cardíacas, como la fibrilación auricular, que requieren monitoreo constante para su detección y diagnóstico. Estudios recientes muestran que la detección temprana de la fibrilación auricular puede mejorar la calidad de vida y reducir el número de muertes. Actualmente, la tecnología facilita la implementación de sistemas de monitoreo portátiles, convirtiéndose en una rama emergente dentro de la medicina. Además, existe evidencia empírica que sugiere el potencial de la inteligencia artificial en la detección de arritmias, incluyendo la fibrilación auricular y otras arritmias. Este proyecto implementó un conjunto de modelos de Redes Neuronales Profundas (RNP) comprimidos para detectar la fibrilación auricular. Se desarrollaron varios modelos compactos de RNP para lograr una precisión de vanguardia con un número mínimo de parámetros. Sumado a esto, se aplicaron diferentes estrategias de compresión para reducir el tamaño y la complejidad computacional de estos modelos compactos. Además, proponemos la implementación de aprendizaje contrastivo para mejorar el rendimiento de una RNP que clasifica la fibrilación auricular en escenarios con pocos datos etiquetados, modelos pequeños y datos ruidosos. Presentamos nuestros resultados en cuanto a precisión, requisitos de memoria y complejidad computacional en términos de operaciones en punto flotante (FLOPs). También comparamos nuestros resultados con otros estudios similares que utilizaron Redes Neuronales Profundas para la detección de la fibrilación auricular. Este estudio sugiere que es posible detectar la fibrilación auricular utilizando modelos de baja complejidad que son factibles de implementar en dispositivos portátiles sin disminuir la precisión de la predicción. | |
| dc.description.abstractenglish | In the present era, there is a decline in the accessibility of healthcare services worldwide, primarily attributable to the global expansion of the population. Consequently, the mortality rate associated with illnesses necessitating specialized diagnostic services has risen. Among the most alarming instances are ischemic heart diseases, representing leading causes of global mortality. This is particularly evident in the case of cardiac arrhythmias like atrial fibrillation, demanding continuous monitoring for timely detection and diagnosis. Recent research indicates that the early identification of atrial fibrillation (AF) has the potential to enhance the quality of life and diminish the number of fatalities. Modern technology facilitates the seamless deployment of portable monitoring systems, emerging as a burgeoning field within the medical domain. Furthermore, empirical evidence supports the notion of artificial intelligence having substantial potential in the detection of arrhythmias, encompassing AF and other cardiac irregularities. This initiative details the execution of a set of compressed Deep Neural Models (DNN) for detecting AF. Numerous streamlined DNN models were formulated to attain cutting-edge precision with minimal parameters. Various compression methodologies were employed to diminish the dimensions and computational intricacies of these condensed models. Additionally, we advocate for the incorporation of contrastive learning to enhance the performance of a DNN specializing in the classification of atrial fibrillation, especially in situations featuring scarce labeled data, compact models, and noisy datasets. Our findings encompass accuracy, memory requisites, and computational intricacy in terms of Floating-point operations (FLOPs). We also compared our results with other similar researches that used Deep Neural Networks for the detection of atrial fibrillation. This investigation posits the viability of detecting AF through the utilization of low-complexity models, which are practicable for implementation in portable devices, all while maintaining prediction accuracy. | |
| dc.description.cvlac | https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0001921899 | |
| dc.description.degreelevel | Maestría | |
| dc.description.degreename | Magíster en Ingeniería Electrónica | |
| dc.description.googlescholar | https://scholar.google.com/citations?user=R35Q3h8AAAAJ&hl=es | |
| dc.description.orcid | https://orcid.org/0000-0003-1425-1516 | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.instname | Universidad Industrial de Santander | |
| dc.identifier.reponame | Universidad Industrial de Santander | |
| dc.identifier.repourl | https://noesis.uis.edu.co | |
| dc.identifier.uri | https://noesis.uis.edu.co/handle/20.500.14071/47951 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad Industrial de Santander | |
| dc.publisher.faculty | Facultad de Ingeníerias Fisicomecánicas | |
| dc.publisher.program | Maestría en Ingeniería Electrónica | |
| dc.publisher.school | Escuela de Ingenierías Eléctrica, Electrónica y Telecomunicaciones | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
| dc.rights.coar | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.creativecommons | Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0) | |
| dc.rights.license | Atribución 2.5 Colombia (CC BY 2.5 CO) | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc/4.0/ | |
| dc.subject | En el borde | |
| dc.subject | Detecci´on Autom´atica | |
| dc.subject | Red Neuronal Convolucional | |
| dc.subject | Aprendizaje Profundo | |
| dc.subject | ECG | |
| dc.subject | Dispositivo Portable | |
| dc.subject | Fibrilación Auricular | |
| dc.subject | Arritmia cardiaca | |
| dc.subject.keyword | Atrial Fibrillation | |
| dc.subject.keyword | At the edge | |
| dc.subject.keyword | Automatic Detection | |
| dc.subject.keyword | Cardiac Arrhythmia | |
| dc.subject.keyword | Convo lutional Neural Network | |
| dc.subject.keyword | Deep Learning | |
| dc.subject.keyword | ECG | |
| dc.subject.keyword | Wearable | |
| dc.title | COMPRESIÓN DE MODELOS BASADOS EN APRENDIZAJE PROFUNDO PARA LA DETECCIÓN DE LA FIBRILACIÓN AURICULAR | |
| dc.title.english | Compression of Deep Learning-Based Models for the Detection of Atrial Fibrillation | |
| dc.type.coar | http://purl.org/coar/resource_type/c_bdcc | |
| dc.type.hasversion | http://purl.org/coar/version/c_b1a7d7d4d402bcce | |
| dc.type.local | Tesis/Trabajo de grado - Monografía - Maestría | |
| dspace.entity.type | Publication |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Carta de autorización.pdf
- Tamaño:
- 1.1 MB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Documento.pdf
- Tamaño:
- 999.5 KB
- Formato:
- Adobe Portable Document Format
Cargando...
- Nombre:
- Nota de proyecto.pdf
- Tamaño:
- 289.18 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.17 KB
- Formato:
- Item-specific license agreed to upon submission
- Descripción:
